Use of thermography on roofing performance for rural constructions

Detalhes bibliográficos
Autor(a) principal: Akamine, Luana Alves
Data de Publicação: 2019
Outros Autores: Araujo, Kari Katiele Souza, Sena, Carolina Carvalho, Passini, Roberta
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.19084/RCA17215
Resumo: Roof coverings are responsible for promoting a suitable environment for animal production, in addition to be one of the main factors interfering with heat transfer. In this context, this study aimed to assess different roof covers over reduced-scale shed prototypes through thermography. The experimental design was completely randomized with five treatments (TT, thermal; RT, recycled (Tetra Pak); ACT, asbestos-cement; BT, bamboo; and AT, aluminum tile) and 14 repetitions, one for each assessment day. For roofing thermal analysis, thermographic images were taken by a thermographic camera (FLIR® TR420), which measured surface temperature changes (external and internal) at 8:00, 10:00, 12:00, 14:00 and 16:00 h, over 14 days. Environmental temperature was measured inside each prototype. BT roofing showed to be efficient, with values of intermediate surface temperatures, enabling its use in replacing RT, AcT and AT roofing tiles. These other tiles had no difference from each other and showed the worst performances.
id RCAP_c119b2b84c050387907cbb9eff955a08
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/16651
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Use of thermography on roofing performance for rural constructionsUso da termografia no desempenho de coberturas para construções ruraisGeralRoof coverings are responsible for promoting a suitable environment for animal production, in addition to be one of the main factors interfering with heat transfer. In this context, this study aimed to assess different roof covers over reduced-scale shed prototypes through thermography. The experimental design was completely randomized with five treatments (TT, thermal; RT, recycled (Tetra Pak); ACT, asbestos-cement; BT, bamboo; and AT, aluminum tile) and 14 repetitions, one for each assessment day. For roofing thermal analysis, thermographic images were taken by a thermographic camera (FLIR® TR420), which measured surface temperature changes (external and internal) at 8:00, 10:00, 12:00, 14:00 and 16:00 h, over 14 days. Environmental temperature was measured inside each prototype. BT roofing showed to be efficient, with values of intermediate surface temperatures, enabling its use in replacing RT, AcT and AT roofing tiles. These other tiles had no difference from each other and showed the worst performances.As coberturas são responsáveis por promover um ambiente mais adequado à produção animal, sendo os materiais de cobertura uns dos principais fatores que interferem nessa transferência térmica. Nesse contexto, objetivou-se avaliar através da termografia, o desempenho de diferentes coberturas em modelos reduzidos de galpões. O delineamento adotado foi inteiramente casualizado com cinco tratamentos, sendo diferentes tipos de coberturas: TER - Térmica; REC – Reciclada (Tetra-Pak); CIA – Cimento-amianto; BAM – Bambu e ALU – Alumínio, com 14 repetições, referentes aos dias de coleta. Para a análise térmica dos materiais de cobertura foram utilizadas imagens termográficas utilizando-se uma câmera termográfica TR420, da FLIR, que mensurou a variação das temperaturas superficiais (externa e interna) registradas nos horários das 8, 10, 12, 14 e 16 h, no período de 14 dias experimentais. Foi coletada a temperatura ambiente no interior de cada modelo reduzido. A cobertura de bambu mostrou-se eficiente, apresentando valores de temperaturas superficiais intermediários, o que possibilita seu uso em substituição às telhas reciclada, cimento amianto e alumínio, as quais não diferiram entre si e apresentaram os piores desempenhos.Sociedade de Ciências Agrárias de Portugal2019-01-14T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.19084/RCA17215eng2183-041X0871-018XAkamine, Luana AlvesAraujo, Kari Katiele SouzaSena, Carolina CarvalhoPassini, Robertainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-06T09:24:45Zoai:ojs.revistas.rcaap.pt:article/16651Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:31:01.190739Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Use of thermography on roofing performance for rural constructions
Uso da termografia no desempenho de coberturas para construções rurais
title Use of thermography on roofing performance for rural constructions
spellingShingle Use of thermography on roofing performance for rural constructions
Akamine, Luana Alves
Geral
title_short Use of thermography on roofing performance for rural constructions
title_full Use of thermography on roofing performance for rural constructions
title_fullStr Use of thermography on roofing performance for rural constructions
title_full_unstemmed Use of thermography on roofing performance for rural constructions
title_sort Use of thermography on roofing performance for rural constructions
author Akamine, Luana Alves
author_facet Akamine, Luana Alves
Araujo, Kari Katiele Souza
Sena, Carolina Carvalho
Passini, Roberta
author_role author
author2 Araujo, Kari Katiele Souza
Sena, Carolina Carvalho
Passini, Roberta
author2_role author
author
author
dc.contributor.author.fl_str_mv Akamine, Luana Alves
Araujo, Kari Katiele Souza
Sena, Carolina Carvalho
Passini, Roberta
dc.subject.por.fl_str_mv Geral
topic Geral
description Roof coverings are responsible for promoting a suitable environment for animal production, in addition to be one of the main factors interfering with heat transfer. In this context, this study aimed to assess different roof covers over reduced-scale shed prototypes through thermography. The experimental design was completely randomized with five treatments (TT, thermal; RT, recycled (Tetra Pak); ACT, asbestos-cement; BT, bamboo; and AT, aluminum tile) and 14 repetitions, one for each assessment day. For roofing thermal analysis, thermographic images were taken by a thermographic camera (FLIR® TR420), which measured surface temperature changes (external and internal) at 8:00, 10:00, 12:00, 14:00 and 16:00 h, over 14 days. Environmental temperature was measured inside each prototype. BT roofing showed to be efficient, with values of intermediate surface temperatures, enabling its use in replacing RT, AcT and AT roofing tiles. These other tiles had no difference from each other and showed the worst performances.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-14T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.19084/RCA17215
url https://doi.org/10.19084/RCA17215
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2183-041X
0871-018X
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Sociedade de Ciências Agrárias de Portugal
publisher.none.fl_str_mv Sociedade de Ciências Agrárias de Portugal
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817551744396165120