Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.5/19777 |
Resumo: | Purpose: One of the bioelectrical impedance spectroscopy (BIS) requirement is to avoid performing physical activity in the 12-24h prior measurement, which can be difficult in highly active populations. This investigation aimed: to examine if moderate to vigorous physical activity (MVPA) performed in 12-24h prior BIS testing, affects the validity of determining total body water (TBW), extracellular water (ECW) and intracellular water (ICW) using dilution techniques as the reference method. Methods: Twenty-seven healthy highly active males, aged 20 to 39 years (72.4 ± 8.7 Kg;1.77 ± 0.07 m) were evaluated. BIS and dilution techniques were used to assess TBW, ECW, and ICW. Pearson coefficient of correlation was used to analyze if MVPA was associated with the difference between methods for TBW, ECW, and ICW. Results: No significant differences between BIS and the dilution technique for TBW, ECW, and ICW volumes were observed (p>0.05). For all water compartments, no association was found between MVPA in the previous 12-24h with the differences between methods (p>0.05). Conclusion: This study showed that performing MVPA 12-24h prior measuring water compartments may not compromise a valid estimation of TBW, ECW, and ICW from BIS compared to dilution techniques. Indeed, the magnitude of the differences between methods in body water assessment was not related with the amount of MVPA performed by highly active adults. |
id |
RCAP_c1f939ff89e8d3ccc1057bf6b79b82c2 |
---|---|
oai_identifier_str |
oai:www.repository.utl.pt:10400.5/19777 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment?Physical activityMVPABody water compartmentsBioelectrical impedanceDilution techniqueTotal body waterExtracellular waterIntracellular waterBioelectrical impedance spectroscopyAtividade físicaAFMVCompartimentos de águaBioimpedância elétricaTécnicas de diluiçãoÁgua corporal totalÁgua extracelularÁgua intracelularBioimpedância elétrica por espectroscopiaDomínio/Área Científica::Ciências Médicas::Outras Ciências MédicasPurpose: One of the bioelectrical impedance spectroscopy (BIS) requirement is to avoid performing physical activity in the 12-24h prior measurement, which can be difficult in highly active populations. This investigation aimed: to examine if moderate to vigorous physical activity (MVPA) performed in 12-24h prior BIS testing, affects the validity of determining total body water (TBW), extracellular water (ECW) and intracellular water (ICW) using dilution techniques as the reference method. Methods: Twenty-seven healthy highly active males, aged 20 to 39 years (72.4 ± 8.7 Kg;1.77 ± 0.07 m) were evaluated. BIS and dilution techniques were used to assess TBW, ECW, and ICW. Pearson coefficient of correlation was used to analyze if MVPA was associated with the difference between methods for TBW, ECW, and ICW. Results: No significant differences between BIS and the dilution technique for TBW, ECW, and ICW volumes were observed (p>0.05). For all water compartments, no association was found between MVPA in the previous 12-24h with the differences between methods (p>0.05). Conclusion: This study showed that performing MVPA 12-24h prior measuring water compartments may not compromise a valid estimation of TBW, ECW, and ICW from BIS compared to dilution techniques. Indeed, the magnitude of the differences between methods in body water assessment was not related with the amount of MVPA performed by highly active adults.Objetivo: Um dos requisitos de bioimpedância elétrica por espectroscopia prende-se com evitar a prática de atividade física nas 12-24h antes da medição, o que pode ser difícil em populações altamente ativas. Esta investigação teve como objetivo: examinar se a atividade física moderada a vigorosa (AFMV) realizada entre 12-24h antes do teste de bioimpedância elétrica por espectroscopia afeta a validade da determinação da água corporal total (ACT), água extracelular (AEC), e água intracelular (AIC) usando técnicas de diluição como o método de referência. Métodos: Foram avaliados vinte e sete homens saudáveis, altamente ativos, com idades entre os 20 e os 39 anos (72,4 ± 8,7Kg; 1,77 ± 0.07m). A bioimpedância elétrica por espectroscopia e as técnicas de diluição foram usadas para avaliar TBW, ECW e ICW. O coeficiente de correlação de Pearson foi usado para analisar se a AFMV estava associada à diferença entre os métodos para ACT, AEC e AIC. Resultados: Não foram observadas diferenças significativas entre a bioimpedância elétrica por espectroscopia e a técnica de diluição para os volumes ACT, AEC e AIC (p> 0,05). Para todos os compartimentos de água, não foi encontrada associação entre AFMV com as diferenças entre os métodos (p> 0,05). Conclusões: O presente estudo mostrou que a realização de AFMV 12-24h antes da medição dos compartimentos de água poderá não comprometer uma estimativa válida de ACT, AEC e AIC do BIS em comparação com as técnicas de diluição. De fato, a magnitude das diferenças entre os métodos na avaliação da água corporal não demonstrou associação com a quantidade de AFMV realizada por adultos altamente ativos.Silva, Analiza Mónica Lopes AlmeidaRepositório da Universidade de LisboaCarapeto, Bárbara Raquel Quintino2020-02-26T09:51:53Z20182018-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.5/19777TID:202442110enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-06T14:49:15Zoai:www.repository.utl.pt:10400.5/19777Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:04:37.962393Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
title |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
spellingShingle |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? Carapeto, Bárbara Raquel Quintino Physical activity MVPA Body water compartments Bioelectrical impedance Dilution technique Total body water Extracellular water Intracellular water Bioelectrical impedance spectroscopy Atividade física AFMV Compartimentos de água Bioimpedância elétrica Técnicas de diluição Água corporal total Água extracelular Água intracelular Bioimpedância elétrica por espectroscopia Domínio/Área Científica::Ciências Médicas::Outras Ciências Médicas |
title_short |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
title_full |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
title_fullStr |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
title_full_unstemmed |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
title_sort |
Does performing moderate-to-vigorous physical activity in 12 to 24 hours prior Bioelectrical Impedance Analysis affects the validity of body water compartments assessment? |
author |
Carapeto, Bárbara Raquel Quintino |
author_facet |
Carapeto, Bárbara Raquel Quintino |
author_role |
author |
dc.contributor.none.fl_str_mv |
Silva, Analiza Mónica Lopes Almeida Repositório da Universidade de Lisboa |
dc.contributor.author.fl_str_mv |
Carapeto, Bárbara Raquel Quintino |
dc.subject.por.fl_str_mv |
Physical activity MVPA Body water compartments Bioelectrical impedance Dilution technique Total body water Extracellular water Intracellular water Bioelectrical impedance spectroscopy Atividade física AFMV Compartimentos de água Bioimpedância elétrica Técnicas de diluição Água corporal total Água extracelular Água intracelular Bioimpedância elétrica por espectroscopia Domínio/Área Científica::Ciências Médicas::Outras Ciências Médicas |
topic |
Physical activity MVPA Body water compartments Bioelectrical impedance Dilution technique Total body water Extracellular water Intracellular water Bioelectrical impedance spectroscopy Atividade física AFMV Compartimentos de água Bioimpedância elétrica Técnicas de diluição Água corporal total Água extracelular Água intracelular Bioimpedância elétrica por espectroscopia Domínio/Área Científica::Ciências Médicas::Outras Ciências Médicas |
description |
Purpose: One of the bioelectrical impedance spectroscopy (BIS) requirement is to avoid performing physical activity in the 12-24h prior measurement, which can be difficult in highly active populations. This investigation aimed: to examine if moderate to vigorous physical activity (MVPA) performed in 12-24h prior BIS testing, affects the validity of determining total body water (TBW), extracellular water (ECW) and intracellular water (ICW) using dilution techniques as the reference method. Methods: Twenty-seven healthy highly active males, aged 20 to 39 years (72.4 ± 8.7 Kg;1.77 ± 0.07 m) were evaluated. BIS and dilution techniques were used to assess TBW, ECW, and ICW. Pearson coefficient of correlation was used to analyze if MVPA was associated with the difference between methods for TBW, ECW, and ICW. Results: No significant differences between BIS and the dilution technique for TBW, ECW, and ICW volumes were observed (p>0.05). For all water compartments, no association was found between MVPA in the previous 12-24h with the differences between methods (p>0.05). Conclusion: This study showed that performing MVPA 12-24h prior measuring water compartments may not compromise a valid estimation of TBW, ECW, and ICW from BIS compared to dilution techniques. Indeed, the magnitude of the differences between methods in body water assessment was not related with the amount of MVPA performed by highly active adults. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018 2018-01-01T00:00:00Z 2020-02-26T09:51:53Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.5/19777 TID:202442110 |
url |
http://hdl.handle.net/10400.5/19777 |
identifier_str_mv |
TID:202442110 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131138466250752 |