Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis

Detalhes bibliográficos
Autor(a) principal: Fonseca, Sara Cristina Pereira
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/92935
Resumo: Cardiovascular diseases represent the leading cause of mortality and disability worldwide. Besides, it is estimated that these numbers will increase significantly in the future. More specifically, atherosclerosis is present in most of the main cardiovascular diseases, making its study urgent and important to develop new diagnostic tools. The most relevant limitation in the current investigation of the evaluation of atherosclerosis is the impossibility to distinguish stable and prone to rupture (unstable) plaques in coronary arteries. Associated with the instability phenomena, in plaques prone to rupture, are increased thickness of tissue layers (already detectable but not provide an unequivocal diagnosis) and inflammatory processes (not yet detectable but only present when the lesion evolves higher risk to rupture). Aiming to detect the precise location of inflammatory processes, two types of contrast agents (nano probes) were synthetized, gold nanoparticles and microbubbles. Also, to replicate the behavior of human arteries, three-dimensional tissue simulating structures (phantoms) were fabricated and optimized. To evaluate the performance of the contrast agents, both in the phantoms and post-mortem human arteries, optical coherence tomography (OCT) images were acquired in a clinical environment, and other techniques were performed (confocal microscopy, scanning electron microscopy, atomic force microscopy) to characterize the samples. Microbubbles revealed to be a better contrast agent than gold nanoparticles having a clearly noticeable enhancement of the OCT signal. After the acquisition of several OCT images on both types of samples (arteries and phantoms) an automatic imaging processing software was developed to detect the presence of the contrast agents and its posterior location. The software uses MATLAB as a programming language and with a user-friendly interface the user can access numerous parameters of the analyzed image and even edit them manually. In the end of the automatic processing, the user has the information of the number of regions of interest as well as their visual location.
id RCAP_c22d3be398dc99b1b9fdf22cedc56c08
oai_identifier_str oai:run.unl.pt:10362/92935
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosisatherosclerosisinflammationcontrast agentsoptical coherence tomographyimaging processing softwareDomínio/Área Científica::Engenharia e Tecnologia::Engenharia MédicaCardiovascular diseases represent the leading cause of mortality and disability worldwide. Besides, it is estimated that these numbers will increase significantly in the future. More specifically, atherosclerosis is present in most of the main cardiovascular diseases, making its study urgent and important to develop new diagnostic tools. The most relevant limitation in the current investigation of the evaluation of atherosclerosis is the impossibility to distinguish stable and prone to rupture (unstable) plaques in coronary arteries. Associated with the instability phenomena, in plaques prone to rupture, are increased thickness of tissue layers (already detectable but not provide an unequivocal diagnosis) and inflammatory processes (not yet detectable but only present when the lesion evolves higher risk to rupture). Aiming to detect the precise location of inflammatory processes, two types of contrast agents (nano probes) were synthetized, gold nanoparticles and microbubbles. Also, to replicate the behavior of human arteries, three-dimensional tissue simulating structures (phantoms) were fabricated and optimized. To evaluate the performance of the contrast agents, both in the phantoms and post-mortem human arteries, optical coherence tomography (OCT) images were acquired in a clinical environment, and other techniques were performed (confocal microscopy, scanning electron microscopy, atomic force microscopy) to characterize the samples. Microbubbles revealed to be a better contrast agent than gold nanoparticles having a clearly noticeable enhancement of the OCT signal. After the acquisition of several OCT images on both types of samples (arteries and phantoms) an automatic imaging processing software was developed to detect the presence of the contrast agents and its posterior location. The software uses MATLAB as a programming language and with a user-friendly interface the user can access numerous parameters of the analyzed image and even edit them manually. In the end of the automatic processing, the user has the information of the number of regions of interest as well as their visual location.Carvalho, MarianaVieira, PedroRUNFonseca, Sara Cristina Pereira2020-02-18T10:25:01Z2019-1120192019-11-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10362/92935enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T04:41:28Zoai:run.unl.pt:10362/92935Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:37:38.427057Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
title Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
spellingShingle Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
Fonseca, Sara Cristina Pereira
atherosclerosis
inflammation
contrast agents
optical coherence tomography
imaging processing software
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Médica
title_short Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
title_full Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
title_fullStr Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
title_full_unstemmed Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
title_sort Evaluation of atherosclerotic plaques with nano-probes for intravascular cardiological imaging diagnosis
author Fonseca, Sara Cristina Pereira
author_facet Fonseca, Sara Cristina Pereira
author_role author
dc.contributor.none.fl_str_mv Carvalho, Mariana
Vieira, Pedro
RUN
dc.contributor.author.fl_str_mv Fonseca, Sara Cristina Pereira
dc.subject.por.fl_str_mv atherosclerosis
inflammation
contrast agents
optical coherence tomography
imaging processing software
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Médica
topic atherosclerosis
inflammation
contrast agents
optical coherence tomography
imaging processing software
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Médica
description Cardiovascular diseases represent the leading cause of mortality and disability worldwide. Besides, it is estimated that these numbers will increase significantly in the future. More specifically, atherosclerosis is present in most of the main cardiovascular diseases, making its study urgent and important to develop new diagnostic tools. The most relevant limitation in the current investigation of the evaluation of atherosclerosis is the impossibility to distinguish stable and prone to rupture (unstable) plaques in coronary arteries. Associated with the instability phenomena, in plaques prone to rupture, are increased thickness of tissue layers (already detectable but not provide an unequivocal diagnosis) and inflammatory processes (not yet detectable but only present when the lesion evolves higher risk to rupture). Aiming to detect the precise location of inflammatory processes, two types of contrast agents (nano probes) were synthetized, gold nanoparticles and microbubbles. Also, to replicate the behavior of human arteries, three-dimensional tissue simulating structures (phantoms) were fabricated and optimized. To evaluate the performance of the contrast agents, both in the phantoms and post-mortem human arteries, optical coherence tomography (OCT) images were acquired in a clinical environment, and other techniques were performed (confocal microscopy, scanning electron microscopy, atomic force microscopy) to characterize the samples. Microbubbles revealed to be a better contrast agent than gold nanoparticles having a clearly noticeable enhancement of the OCT signal. After the acquisition of several OCT images on both types of samples (arteries and phantoms) an automatic imaging processing software was developed to detect the presence of the contrast agents and its posterior location. The software uses MATLAB as a programming language and with a user-friendly interface the user can access numerous parameters of the analyzed image and even edit them manually. In the end of the automatic processing, the user has the information of the number of regions of interest as well as their visual location.
publishDate 2019
dc.date.none.fl_str_mv 2019-11
2019
2019-11-01T00:00:00Z
2020-02-18T10:25:01Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/92935
url http://hdl.handle.net/10362/92935
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137992707670016