Resumo: | The present work focuses on the production of thermal energy in University building greenhouses in cold climate conditions. The building model uses a system of energy and mass balance integral equations, which are solved by the Runge–Kutta–Felberg method with error control. This numerical study is about the thermal behaviour of a university building with complex topology, in winter and transient conditions. The thermal comfort of the occupants, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. This building has 319 compartments distributed by four floors and it is equipped with one internal greenhouse in the third floor. This greenhouse is located on the south facing facade and the heated air in this space will be transported to compartments located on the north facing façade. The spaces subject to the influence of the heated air coming from the greenhouse improve the level of thermal comfort of its occupants. The level of indoor air quality in occupied spaces is acceptable according to international standards. |
id |
RCAP_c29ddeaebc9a3409eca1062cbc2d334f |
---|---|
oai_identifier_str |
oai:sapientia.ualg.pt:10400.1/16800 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Production of thermal energy in university building greenhouses in cold climate conditionsSistemas HVACFluirTemperaturaEstratégiasModeloThe present work focuses on the production of thermal energy in University building greenhouses in cold climate conditions. The building model uses a system of energy and mass balance integral equations, which are solved by the Runge–Kutta–Felberg method with error control. This numerical study is about the thermal behaviour of a university building with complex topology, in winter and transient conditions. The thermal comfort of the occupants, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. This building has 319 compartments distributed by four floors and it is equipped with one internal greenhouse in the third floor. This greenhouse is located on the south facing facade and the heated air in this space will be transported to compartments located on the north facing façade. The spaces subject to the influence of the heated air coming from the greenhouse improve the level of thermal comfort of its occupants. The level of indoor air quality in occupied spaces is acceptable according to international standards.EDP SciencesSapientiaConceição, EusébioGomes, JoãoLúcio, Maria Manuela Jacinto Do RosárioAwbi, Hazim2021-07-21T16:31:26Z2021-042021-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.1/16800eng2267-124210.1051/e3sconf/202124603004info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-11-29T10:38:40Zoai:sapientia.ualg.pt:10400.1/16800Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-11-29T10:38:40Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Production of thermal energy in university building greenhouses in cold climate conditions |
title |
Production of thermal energy in university building greenhouses in cold climate conditions |
spellingShingle |
Production of thermal energy in university building greenhouses in cold climate conditions Conceição, Eusébio Sistemas HVAC Fluir Temperatura Estratégias Modelo |
title_short |
Production of thermal energy in university building greenhouses in cold climate conditions |
title_full |
Production of thermal energy in university building greenhouses in cold climate conditions |
title_fullStr |
Production of thermal energy in university building greenhouses in cold climate conditions |
title_full_unstemmed |
Production of thermal energy in university building greenhouses in cold climate conditions |
title_sort |
Production of thermal energy in university building greenhouses in cold climate conditions |
author |
Conceição, Eusébio |
author_facet |
Conceição, Eusébio Gomes, João Lúcio, Maria Manuela Jacinto Do Rosário Awbi, Hazim |
author_role |
author |
author2 |
Gomes, João Lúcio, Maria Manuela Jacinto Do Rosário Awbi, Hazim |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Sapientia |
dc.contributor.author.fl_str_mv |
Conceição, Eusébio Gomes, João Lúcio, Maria Manuela Jacinto Do Rosário Awbi, Hazim |
dc.subject.por.fl_str_mv |
Sistemas HVAC Fluir Temperatura Estratégias Modelo |
topic |
Sistemas HVAC Fluir Temperatura Estratégias Modelo |
description |
The present work focuses on the production of thermal energy in University building greenhouses in cold climate conditions. The building model uses a system of energy and mass balance integral equations, which are solved by the Runge–Kutta–Felberg method with error control. This numerical study is about the thermal behaviour of a university building with complex topology, in winter and transient conditions. The thermal comfort of the occupants, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. This building has 319 compartments distributed by four floors and it is equipped with one internal greenhouse in the third floor. This greenhouse is located on the south facing facade and the heated air in this space will be transported to compartments located on the north facing façade. The spaces subject to the influence of the heated air coming from the greenhouse improve the level of thermal comfort of its occupants. The level of indoor air quality in occupied spaces is acceptable according to international standards. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-21T16:31:26Z 2021-04 2021-04-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.1/16800 |
url |
http://hdl.handle.net/10400.1/16800 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2267-1242 10.1051/e3sconf/202124603004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDP Sciences |
publisher.none.fl_str_mv |
EDP Sciences |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817549768072626176 |