Hydrodynamic model for three-phase internal- and external-loop airlift reactors

Detalhes bibliográficos
Autor(a) principal: Freitas, Carla Maria Duarte de
Data de Publicação: 1999
Outros Autores: Fialová, Maria, Zahradnik, Jindrich, Teixeira, J. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/1430
Resumo: A mathematical model predicting the hydrodynamic behaviour of three-phase airlift reactors, working with low-density solids and with high solids loading, was developed. The model allows for the prediction of local gas holdup and liquid velocity in airlift bioreactors. Model was validated for an external-loop airlift reactor and an internal-loop airlift reactor with an enlarged degassing zone, being a good agreement obtained between calculated and experimental data.
id RCAP_c472df5079a430e3a0f75014158fe41d
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/1430
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Hydrodynamic model for three-phase internal- and external-loop airlift reactorsThree-phase reactorHydrodynamic modelGas holdupLiquid velocityScience & TechnologyA mathematical model predicting the hydrodynamic behaviour of three-phase airlift reactors, working with low-density solids and with high solids loading, was developed. The model allows for the prediction of local gas holdup and liquid velocity in airlift bioreactors. Model was validated for an external-loop airlift reactor and an internal-loop airlift reactor with an enlarged degassing zone, being a good agreement obtained between calculated and experimental data.Fundação para a Ciência e a Tecnologia (FCT); Junta Nacional de Investigação Científica e Tecnológica (JNICT) - PRAXIS 2/2.1/BIO/1061/95; Instituto de Biotecnologia e Química Fina (IBQF) - GGP XXI/BD/2937/96.Elsevier ScienceUniversidade do MinhoFreitas, Carla Maria Duarte deFialová, MariaZahradnik, JindrichTeixeira, J. A.19991999-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/1430engFreitas, C., Fialová, M., Zahradnik, J., & Teixeira, J. A. (1999). Hydrodynamic model for three-phase internal- and external-loop airlift reactors. Chemical Engineering Science, 54(21), 5253-5258. doi: https://doi.org/10.1016/S0009-2509(99)00256-00009-250910.1016/S0009-2509(99)00256-0info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:07:23Zoai:repositorium.sdum.uminho.pt:1822/1430Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:58:20.492488Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Hydrodynamic model for three-phase internal- and external-loop airlift reactors
title Hydrodynamic model for three-phase internal- and external-loop airlift reactors
spellingShingle Hydrodynamic model for three-phase internal- and external-loop airlift reactors
Freitas, Carla Maria Duarte de
Three-phase reactor
Hydrodynamic model
Gas holdup
Liquid velocity
Science & Technology
title_short Hydrodynamic model for three-phase internal- and external-loop airlift reactors
title_full Hydrodynamic model for three-phase internal- and external-loop airlift reactors
title_fullStr Hydrodynamic model for three-phase internal- and external-loop airlift reactors
title_full_unstemmed Hydrodynamic model for three-phase internal- and external-loop airlift reactors
title_sort Hydrodynamic model for three-phase internal- and external-loop airlift reactors
author Freitas, Carla Maria Duarte de
author_facet Freitas, Carla Maria Duarte de
Fialová, Maria
Zahradnik, Jindrich
Teixeira, J. A.
author_role author
author2 Fialová, Maria
Zahradnik, Jindrich
Teixeira, J. A.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Freitas, Carla Maria Duarte de
Fialová, Maria
Zahradnik, Jindrich
Teixeira, J. A.
dc.subject.por.fl_str_mv Three-phase reactor
Hydrodynamic model
Gas holdup
Liquid velocity
Science & Technology
topic Three-phase reactor
Hydrodynamic model
Gas holdup
Liquid velocity
Science & Technology
description A mathematical model predicting the hydrodynamic behaviour of three-phase airlift reactors, working with low-density solids and with high solids loading, was developed. The model allows for the prediction of local gas holdup and liquid velocity in airlift bioreactors. Model was validated for an external-loop airlift reactor and an internal-loop airlift reactor with an enlarged degassing zone, being a good agreement obtained between calculated and experimental data.
publishDate 1999
dc.date.none.fl_str_mv 1999
1999-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/1430
url https://hdl.handle.net/1822/1430
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Freitas, C., Fialová, M., Zahradnik, J., & Teixeira, J. A. (1999). Hydrodynamic model for three-phase internal- and external-loop airlift reactors. Chemical Engineering Science, 54(21), 5253-5258. doi: https://doi.org/10.1016/S0009-2509(99)00256-0
0009-2509
10.1016/S0009-2509(99)00256-0
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132373529395200