Different antenna designs for non-contact vital signs measurement: a review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/11468 |
Resumo: | Cardiopulmonary activity measured through contactless means is a hot topic within the research community. The Doppler radar is an approach often used to acquire vital signs in real time and to further estimate their rates, in a remote way and without requiring direct contact with subjects. Many solutions have been proposed in the literature, using different transceivers and operation modes. Nonetheless, all different strategies have a common goal: enhance the system efficiency, reduce the manufacturing cost, and minimize the overall size of the system. Antennas are a key component for these systems since they can influence the radar robustness directly. Therefore, antennas must be designed with care, facing several trade-offs to meet all the system requirements. In this sense, it is necessary to define the proper guidelines that need to be followed in the antenna design. In this manuscript, an extensive review on different antenna designs for non-contact vital signals measurements is presented. It is intended to point out and quantify which parameters are crucial for the optimal radar operation, for non-contact vital signs' acquisition. |
id |
RCAP_c53b52c798348930e37b6440fd074e45 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/11468 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Different antenna designs for non-contact vital signs measurement: a reviewAntennasRadarVital-signsCWUWBCardiopulmonary activity measured through contactless means is a hot topic within the research community. The Doppler radar is an approach often used to acquire vital signs in real time and to further estimate their rates, in a remote way and without requiring direct contact with subjects. Many solutions have been proposed in the literature, using different transceivers and operation modes. Nonetheless, all different strategies have a common goal: enhance the system efficiency, reduce the manufacturing cost, and minimize the overall size of the system. Antennas are a key component for these systems since they can influence the radar robustness directly. Therefore, antennas must be designed with care, facing several trade-offs to meet all the system requirements. In this sense, it is necessary to define the proper guidelines that need to be followed in the antenna design. In this manuscript, an extensive review on different antenna designs for non-contact vital signals measurements is presented. It is intended to point out and quantify which parameters are crucial for the optimal radar operation, for non-contact vital signs' acquisition.MDPIRCIPLGouveia, CarolinaLoss, CarolinePinho, P.Vieira, José2020-04-17T14:04:20Z2019-112019-11-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/11468engGOUVEIA, Carolina; [et al] – Different antenna designs for non-contact vital signs measurement: a review. Electronics. ISSN 2079-9292. Vol. 8, N.º 11 (2019), pp. 1-242079-929210.3390/electronics8111294info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T10:02:45Zoai:repositorio.ipl.pt:10400.21/11468Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:19:43.036690Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Different antenna designs for non-contact vital signs measurement: a review |
title |
Different antenna designs for non-contact vital signs measurement: a review |
spellingShingle |
Different antenna designs for non-contact vital signs measurement: a review Gouveia, Carolina Antennas Radar Vital-signs CW UWB |
title_short |
Different antenna designs for non-contact vital signs measurement: a review |
title_full |
Different antenna designs for non-contact vital signs measurement: a review |
title_fullStr |
Different antenna designs for non-contact vital signs measurement: a review |
title_full_unstemmed |
Different antenna designs for non-contact vital signs measurement: a review |
title_sort |
Different antenna designs for non-contact vital signs measurement: a review |
author |
Gouveia, Carolina |
author_facet |
Gouveia, Carolina Loss, Caroline Pinho, P. Vieira, José |
author_role |
author |
author2 |
Loss, Caroline Pinho, P. Vieira, José |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Gouveia, Carolina Loss, Caroline Pinho, P. Vieira, José |
dc.subject.por.fl_str_mv |
Antennas Radar Vital-signs CW UWB |
topic |
Antennas Radar Vital-signs CW UWB |
description |
Cardiopulmonary activity measured through contactless means is a hot topic within the research community. The Doppler radar is an approach often used to acquire vital signs in real time and to further estimate their rates, in a remote way and without requiring direct contact with subjects. Many solutions have been proposed in the literature, using different transceivers and operation modes. Nonetheless, all different strategies have a common goal: enhance the system efficiency, reduce the manufacturing cost, and minimize the overall size of the system. Antennas are a key component for these systems since they can influence the radar robustness directly. Therefore, antennas must be designed with care, facing several trade-offs to meet all the system requirements. In this sense, it is necessary to define the proper guidelines that need to be followed in the antenna design. In this manuscript, an extensive review on different antenna designs for non-contact vital signals measurements is presented. It is intended to point out and quantify which parameters are crucial for the optimal radar operation, for non-contact vital signs' acquisition. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-11 2019-11-01T00:00:00Z 2020-04-17T14:04:20Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/11468 |
url |
http://hdl.handle.net/10400.21/11468 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
GOUVEIA, Carolina; [et al] – Different antenna designs for non-contact vital signs measurement: a review. Electronics. ISSN 2079-9292. Vol. 8, N.º 11 (2019), pp. 1-24 2079-9292 10.3390/electronics8111294 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
MDPI |
publisher.none.fl_str_mv |
MDPI |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133464758321152 |