Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents

Detalhes bibliográficos
Autor(a) principal: Maia, Alexandra S.
Data de Publicação: 2013
Outros Autores: Ribeiro, Ana R., Castro, Paula M. L., Tiritan, Maria E.
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/13243
Resumo: Microbial degradation of fluorinated pharmaceuticals during wastewater treatment processes remains inadequate in most situations. Due to incomplete elimination, these residues are continually being introduced into the aquatic environments in which they settle throughout time since many of them are resistant to degradation. Fluoroquinolone antibiotics due to its persistence and implication on resistant-bacteria development, pose special interest in environmental analysis. Due to their zwitterionic characteristics, the extraction/pre-concentration process of fluoroquinolones prior analyses is an unquestionable challenge. This work compares the solid phase extraction efficiency of four fluoroquinolones (Ofloxacin, Norfloxacin, Ciprofloxacin and Moxifloxacin) from wastewater effluents by different commercial sorbents. Prior to wastewater analysis, preliminary tests were conducted in distilled water with a larger number of sorbents. Different experimental protocols and sorbents, namely OASIS® HLB, OASIS® WAX, OASIS® WCX (500 mg) and the molecularly imprinted polymer SupelMIP TM were applied to wastewater samples collected from a municipal wastewater treatment plant from the north of Portugal. The extracts were analyzed by a HPLC withFluorescence Detection validated method using a Luna PFP (2) 3µm column. Despite good results obtained with the molecularly imprinted polymer in distilled water, these cartridges did not perform efficiently when applied to wastewater effluents, probably due to the sample high complexity especially since their specific design for biological samples. Regarding OASIS® considered sorbents; HLB 500mg and WAX 500mg presented the best recovery rates of the fourstudied antibiotics, between 84-75% and 64-94%, respectively. Although the recoveries achievedwere not that dissimilar between the two mentioned sorbents, chromatograms of WAX extracts appear much cleaner in the antibiotics retention times while chromatograms of HLB extractsclearly show the presence of strong polar substances, probably matrix humic and fulvic acids,that behave as resilient interferences in the analysis, disturbing a proper identification of target compounds and reducing chromatographic resolution.
id RCAP_c69ba944b1b461d758b843b4972e4c07
oai_identifier_str oai:repositorio.ucp.pt:10400.14/13243
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial SorbentsFluoroquinolonesSolid Phase ExtractionWastewaterMicrobial degradation of fluorinated pharmaceuticals during wastewater treatment processes remains inadequate in most situations. Due to incomplete elimination, these residues are continually being introduced into the aquatic environments in which they settle throughout time since many of them are resistant to degradation. Fluoroquinolone antibiotics due to its persistence and implication on resistant-bacteria development, pose special interest in environmental analysis. Due to their zwitterionic characteristics, the extraction/pre-concentration process of fluoroquinolones prior analyses is an unquestionable challenge. This work compares the solid phase extraction efficiency of four fluoroquinolones (Ofloxacin, Norfloxacin, Ciprofloxacin and Moxifloxacin) from wastewater effluents by different commercial sorbents. Prior to wastewater analysis, preliminary tests were conducted in distilled water with a larger number of sorbents. Different experimental protocols and sorbents, namely OASIS® HLB, OASIS® WAX, OASIS® WCX (500 mg) and the molecularly imprinted polymer SupelMIP TM were applied to wastewater samples collected from a municipal wastewater treatment plant from the north of Portugal. The extracts were analyzed by a HPLC withFluorescence Detection validated method using a Luna PFP (2) 3µm column. Despite good results obtained with the molecularly imprinted polymer in distilled water, these cartridges did not perform efficiently when applied to wastewater effluents, probably due to the sample high complexity especially since their specific design for biological samples. Regarding OASIS® considered sorbents; HLB 500mg and WAX 500mg presented the best recovery rates of the fourstudied antibiotics, between 84-75% and 64-94%, respectively. Although the recoveries achievedwere not that dissimilar between the two mentioned sorbents, chromatograms of WAX extracts appear much cleaner in the antibiotics retention times while chromatograms of HLB extractsclearly show the presence of strong polar substances, probably matrix humic and fulvic acids,that behave as resilient interferences in the analysis, disturbing a proper identification of target compounds and reducing chromatographic resolution.Veritati - Repositório Institucional da Universidade Católica PortuguesaMaia, Alexandra S.Ribeiro, Ana R.Castro, Paula M. L.Tiritan, Maria E.2013-11-14T16:36:26Z20132013-01-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.14/13243engMAIA, Alexandra S. [et al.] - Degradation of Fluoroquinolone Antibiotics and Identification of Metabolites/Transformation Products by LC-MS/MS. In 39th International Symposium on High Performance Liquid Phase Separations and Related Techniques, Amsterdam, The Netherlands, 16-20 June 2013 – In HPLC 2013 - 39th International Symposium on High Performance Liquid Phase Separations and Related Techniques: Book of Abstracts, (2013) p.941info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-09-06T12:07:56Zoai:repositorio.ucp.pt:10400.14/13243Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-09-06T12:07:56Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
title Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
spellingShingle Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
Maia, Alexandra S.
Fluoroquinolones
Solid Phase Extraction
Wastewater
title_short Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
title_full Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
title_fullStr Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
title_full_unstemmed Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
title_sort Solid Phase Extraction of Fluoroquinolone Antibiotics from Wastewaters – Assessment of Different Commercial Sorbents
author Maia, Alexandra S.
author_facet Maia, Alexandra S.
Ribeiro, Ana R.
Castro, Paula M. L.
Tiritan, Maria E.
author_role author
author2 Ribeiro, Ana R.
Castro, Paula M. L.
Tiritan, Maria E.
author2_role author
author
author
dc.contributor.none.fl_str_mv Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Maia, Alexandra S.
Ribeiro, Ana R.
Castro, Paula M. L.
Tiritan, Maria E.
dc.subject.por.fl_str_mv Fluoroquinolones
Solid Phase Extraction
Wastewater
topic Fluoroquinolones
Solid Phase Extraction
Wastewater
description Microbial degradation of fluorinated pharmaceuticals during wastewater treatment processes remains inadequate in most situations. Due to incomplete elimination, these residues are continually being introduced into the aquatic environments in which they settle throughout time since many of them are resistant to degradation. Fluoroquinolone antibiotics due to its persistence and implication on resistant-bacteria development, pose special interest in environmental analysis. Due to their zwitterionic characteristics, the extraction/pre-concentration process of fluoroquinolones prior analyses is an unquestionable challenge. This work compares the solid phase extraction efficiency of four fluoroquinolones (Ofloxacin, Norfloxacin, Ciprofloxacin and Moxifloxacin) from wastewater effluents by different commercial sorbents. Prior to wastewater analysis, preliminary tests were conducted in distilled water with a larger number of sorbents. Different experimental protocols and sorbents, namely OASIS® HLB, OASIS® WAX, OASIS® WCX (500 mg) and the molecularly imprinted polymer SupelMIP TM were applied to wastewater samples collected from a municipal wastewater treatment plant from the north of Portugal. The extracts were analyzed by a HPLC withFluorescence Detection validated method using a Luna PFP (2) 3µm column. Despite good results obtained with the molecularly imprinted polymer in distilled water, these cartridges did not perform efficiently when applied to wastewater effluents, probably due to the sample high complexity especially since their specific design for biological samples. Regarding OASIS® considered sorbents; HLB 500mg and WAX 500mg presented the best recovery rates of the fourstudied antibiotics, between 84-75% and 64-94%, respectively. Although the recoveries achievedwere not that dissimilar between the two mentioned sorbents, chromatograms of WAX extracts appear much cleaner in the antibiotics retention times while chromatograms of HLB extractsclearly show the presence of strong polar substances, probably matrix humic and fulvic acids,that behave as resilient interferences in the analysis, disturbing a proper identification of target compounds and reducing chromatographic resolution.
publishDate 2013
dc.date.none.fl_str_mv 2013-11-14T16:36:26Z
2013
2013-01-01T00:00:00Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/13243
url http://hdl.handle.net/10400.14/13243
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv MAIA, Alexandra S. [et al.] - Degradation of Fluoroquinolone Antibiotics and Identification of Metabolites/Transformation Products by LC-MS/MS. In 39th International Symposium on High Performance Liquid Phase Separations and Related Techniques, Amsterdam, The Netherlands, 16-20 June 2013 – In HPLC 2013 - 39th International Symposium on High Performance Liquid Phase Separations and Related Techniques: Book of Abstracts, (2013) p.941
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv mluisa.alvim@gmail.com
_version_ 1817546768666066944