Bacterial contamination in health care centers

Detalhes bibliográficos
Autor(a) principal: Monteiro, Ana
Data de Publicação: 2021
Outros Autores: Almeida, Beatriz, Paciência, Inês, Rufo, João Cavaleiro, Ribeiro, Edna, Carolino, Elisabete, Viegas, Carla, Uva, António Sousa, Verde, Sandra Cabo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/118259
Resumo: This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria.
id RCAP_c7458f3261ccd186bd9523b399746689
oai_identifier_str oai:run.unl.pt:10362/118259
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Bacterial contamination in health care centersdifferences between urban and rural settingsAirborne bacteriaAntibiotic resistance profilePrimary Health Care CentersRuralUrbanEnvironmental Science (miscellaneous)SDG 3 - Good Health and Well-beingSDG 11 - Sustainable Cities and CommunitiesThis study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria.Escola Nacional de Saúde Pública (ENSP)Comprehensive Health Research Centre (CHRC) - Pólo ENSPCentro de Investigação em Saúde Pública (CISP/PHRC)RUNMonteiro, AnaAlmeida, BeatrizPaciência, InêsRufo, João CavaleiroRibeiro, EdnaCarolino, ElisabeteViegas, CarlaUva, António SousaVerde, Sandra Cabo2021-05-25T00:57:55Z2021-042021-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10362/118259eng2073-4433PURE: 29762593https://doi.org/10.3390/atmos12040450info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T05:01:11Zoai:run.unl.pt:10362/118259Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:43:50.715110Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Bacterial contamination in health care centers
differences between urban and rural settings
title Bacterial contamination in health care centers
spellingShingle Bacterial contamination in health care centers
Monteiro, Ana
Airborne bacteria
Antibiotic resistance profile
Primary Health Care Centers
Rural
Urban
Environmental Science (miscellaneous)
SDG 3 - Good Health and Well-being
SDG 11 - Sustainable Cities and Communities
title_short Bacterial contamination in health care centers
title_full Bacterial contamination in health care centers
title_fullStr Bacterial contamination in health care centers
title_full_unstemmed Bacterial contamination in health care centers
title_sort Bacterial contamination in health care centers
author Monteiro, Ana
author_facet Monteiro, Ana
Almeida, Beatriz
Paciência, Inês
Rufo, João Cavaleiro
Ribeiro, Edna
Carolino, Elisabete
Viegas, Carla
Uva, António Sousa
Verde, Sandra Cabo
author_role author
author2 Almeida, Beatriz
Paciência, Inês
Rufo, João Cavaleiro
Ribeiro, Edna
Carolino, Elisabete
Viegas, Carla
Uva, António Sousa
Verde, Sandra Cabo
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Escola Nacional de Saúde Pública (ENSP)
Comprehensive Health Research Centre (CHRC) - Pólo ENSP
Centro de Investigação em Saúde Pública (CISP/PHRC)
RUN
dc.contributor.author.fl_str_mv Monteiro, Ana
Almeida, Beatriz
Paciência, Inês
Rufo, João Cavaleiro
Ribeiro, Edna
Carolino, Elisabete
Viegas, Carla
Uva, António Sousa
Verde, Sandra Cabo
dc.subject.por.fl_str_mv Airborne bacteria
Antibiotic resistance profile
Primary Health Care Centers
Rural
Urban
Environmental Science (miscellaneous)
SDG 3 - Good Health and Well-being
SDG 11 - Sustainable Cities and Communities
topic Airborne bacteria
Antibiotic resistance profile
Primary Health Care Centers
Rural
Urban
Environmental Science (miscellaneous)
SDG 3 - Good Health and Well-being
SDG 11 - Sustainable Cities and Communities
description This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria.
publishDate 2021
dc.date.none.fl_str_mv 2021-05-25T00:57:55Z
2021-04
2021-04-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/118259
url http://hdl.handle.net/10362/118259
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2073-4433
PURE: 29762593
https://doi.org/10.3390/atmos12040450
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799138047132958720