Bacterial contamination in health care centers
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10362/118259 |
Resumo: | This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria. |
id |
RCAP_c7458f3261ccd186bd9523b399746689 |
---|---|
oai_identifier_str |
oai:run.unl.pt:10362/118259 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Bacterial contamination in health care centersdifferences between urban and rural settingsAirborne bacteriaAntibiotic resistance profilePrimary Health Care CentersRuralUrbanEnvironmental Science (miscellaneous)SDG 3 - Good Health and Well-beingSDG 11 - Sustainable Cities and CommunitiesThis study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria.Escola Nacional de Saúde Pública (ENSP)Comprehensive Health Research Centre (CHRC) - Pólo ENSPCentro de Investigação em Saúde Pública (CISP/PHRC)RUNMonteiro, AnaAlmeida, BeatrizPaciência, InêsRufo, João CavaleiroRibeiro, EdnaCarolino, ElisabeteViegas, CarlaUva, António SousaVerde, Sandra Cabo2021-05-25T00:57:55Z2021-042021-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10362/118259eng2073-4433PURE: 29762593https://doi.org/10.3390/atmos12040450info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-11T05:01:11Zoai:run.unl.pt:10362/118259Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:43:50.715110Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Bacterial contamination in health care centers differences between urban and rural settings |
title |
Bacterial contamination in health care centers |
spellingShingle |
Bacterial contamination in health care centers Monteiro, Ana Airborne bacteria Antibiotic resistance profile Primary Health Care Centers Rural Urban Environmental Science (miscellaneous) SDG 3 - Good Health and Well-being SDG 11 - Sustainable Cities and Communities |
title_short |
Bacterial contamination in health care centers |
title_full |
Bacterial contamination in health care centers |
title_fullStr |
Bacterial contamination in health care centers |
title_full_unstemmed |
Bacterial contamination in health care centers |
title_sort |
Bacterial contamination in health care centers |
author |
Monteiro, Ana |
author_facet |
Monteiro, Ana Almeida, Beatriz Paciência, Inês Rufo, João Cavaleiro Ribeiro, Edna Carolino, Elisabete Viegas, Carla Uva, António Sousa Verde, Sandra Cabo |
author_role |
author |
author2 |
Almeida, Beatriz Paciência, Inês Rufo, João Cavaleiro Ribeiro, Edna Carolino, Elisabete Viegas, Carla Uva, António Sousa Verde, Sandra Cabo |
author2_role |
author author author author author author author author |
dc.contributor.none.fl_str_mv |
Escola Nacional de Saúde Pública (ENSP) Comprehensive Health Research Centre (CHRC) - Pólo ENSP Centro de Investigação em Saúde Pública (CISP/PHRC) RUN |
dc.contributor.author.fl_str_mv |
Monteiro, Ana Almeida, Beatriz Paciência, Inês Rufo, João Cavaleiro Ribeiro, Edna Carolino, Elisabete Viegas, Carla Uva, António Sousa Verde, Sandra Cabo |
dc.subject.por.fl_str_mv |
Airborne bacteria Antibiotic resistance profile Primary Health Care Centers Rural Urban Environmental Science (miscellaneous) SDG 3 - Good Health and Well-being SDG 11 - Sustainable Cities and Communities |
topic |
Airborne bacteria Antibiotic resistance profile Primary Health Care Centers Rural Urban Environmental Science (miscellaneous) SDG 3 - Good Health and Well-being SDG 11 - Sustainable Cities and Communities |
description |
This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the ma-jority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-05-25T00:57:55Z 2021-04 2021-04-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10362/118259 |
url |
http://hdl.handle.net/10362/118259 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2073-4433 PURE: 29762593 https://doi.org/10.3390/atmos12040450 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799138047132958720 |