A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/62239 |
Resumo: | Virchow-Robin Spaces surround the perforating arteries of the brain and sometimes they become dilated.Studies suggest that those structures are correlated with some conditions such as lacunar strokes, small vesseldiseases, multiple sclerosis or even normal aging. However, the majority of those studies are based on thedetection of those structures by a human expert, in some regions of interest, which is prone to the subjectivityof the person doing the task. Moreover, dilated Virchow-Robin Spaces may look similar to lacunar strokes,making them difficult to identify. Few works have been proposed on the computational detection of dilatedVirchow-Robin Spaces. In this paper, we propose a fully automatic tool, capable of preprocessing the magneticresonance images, extract the most relevant regions of interest and detect dilated Virchow-Robin Spaces. Sucha tool may be useful to eliminate human subjectivity, but also to improve the reproducibility of the studies,leading to more reliable correlations. An application to visualize and count the detected structures was alsobuilt, with the aim of helping in a study of the correlation of lacunar strokes, Virchow-Robin Spaces andvascular dementia |
id |
RCAP_caa94ef05134324638784d543c911746 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/62239 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke studyVirchow-Robin SpacesLacunar StrokeMRIMedical Image AnalysisAutomatic ToolCiências Médicas::Medicina BásicaVirchow-Robin Spaces surround the perforating arteries of the brain and sometimes they become dilated.Studies suggest that those structures are correlated with some conditions such as lacunar strokes, small vesseldiseases, multiple sclerosis or even normal aging. However, the majority of those studies are based on thedetection of those structures by a human expert, in some regions of interest, which is prone to the subjectivityof the person doing the task. Moreover, dilated Virchow-Robin Spaces may look similar to lacunar strokes,making them difficult to identify. Few works have been proposed on the computational detection of dilatedVirchow-Robin Spaces. In this paper, we propose a fully automatic tool, capable of preprocessing the magneticresonance images, extract the most relevant regions of interest and detect dilated Virchow-Robin Spaces. Sucha tool may be useful to eliminate human subjectivity, but also to improve the reproducibility of the studies,leading to more reliable correlations. An application to visualize and count the detected structures was alsobuilt, with the aim of helping in a study of the correlation of lacunar strokes, Virchow-Robin Spaces andvascular dementiaSCITEPRESS – Science and Technology PublicationsUniversidade do MinhoPereira, SérgioMariz, JoséSousa, NunoCorreia, J. H.Silva, Carlos20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/62239engPereira, S., Mariz, J. A., Sousa, N., Correia, J. H., & Silva, C. A. (2015, January). A Fully Automatic Tool for Counting Virchow-Robin Spaces in Magnetic Resonance Imaging for Lacunar Stroke Study. In BIOIMAGING (pp. 69-75).978-989-758-072-710.5220/0005199700690075https://dblp.org/db/conf/biostec/bioimaging2015.htmlinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:44:35Zoai:repositorium.sdum.uminho.pt:1822/62239Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:42:18.398236Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
title |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
spellingShingle |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study Pereira, Sérgio Virchow-Robin Spaces Lacunar Stroke MRI Medical Image Analysis Automatic Tool Ciências Médicas::Medicina Básica |
title_short |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
title_full |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
title_fullStr |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
title_full_unstemmed |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
title_sort |
A fully automatic tool for counting Virchow-Robin spaces in magnetic resonance imaging for lacunar stroke study |
author |
Pereira, Sérgio |
author_facet |
Pereira, Sérgio Mariz, José Sousa, Nuno Correia, J. H. Silva, Carlos |
author_role |
author |
author2 |
Mariz, José Sousa, Nuno Correia, J. H. Silva, Carlos |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Pereira, Sérgio Mariz, José Sousa, Nuno Correia, J. H. Silva, Carlos |
dc.subject.por.fl_str_mv |
Virchow-Robin Spaces Lacunar Stroke MRI Medical Image Analysis Automatic Tool Ciências Médicas::Medicina Básica |
topic |
Virchow-Robin Spaces Lacunar Stroke MRI Medical Image Analysis Automatic Tool Ciências Médicas::Medicina Básica |
description |
Virchow-Robin Spaces surround the perforating arteries of the brain and sometimes they become dilated.Studies suggest that those structures are correlated with some conditions such as lacunar strokes, small vesseldiseases, multiple sclerosis or even normal aging. However, the majority of those studies are based on thedetection of those structures by a human expert, in some regions of interest, which is prone to the subjectivityof the person doing the task. Moreover, dilated Virchow-Robin Spaces may look similar to lacunar strokes,making them difficult to identify. Few works have been proposed on the computational detection of dilatedVirchow-Robin Spaces. In this paper, we propose a fully automatic tool, capable of preprocessing the magneticresonance images, extract the most relevant regions of interest and detect dilated Virchow-Robin Spaces. Sucha tool may be useful to eliminate human subjectivity, but also to improve the reproducibility of the studies,leading to more reliable correlations. An application to visualize and count the detected structures was alsobuilt, with the aim of helping in a study of the correlation of lacunar strokes, Virchow-Robin Spaces andvascular dementia |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 2015-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/62239 |
url |
http://hdl.handle.net/1822/62239 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Pereira, S., Mariz, J. A., Sousa, N., Correia, J. H., & Silva, C. A. (2015, January). A Fully Automatic Tool for Counting Virchow-Robin Spaces in Magnetic Resonance Imaging for Lacunar Stroke Study. In BIOIMAGING (pp. 69-75). 978-989-758-072-7 10.5220/0005199700690075 https://dblp.org/db/conf/biostec/bioimaging2015.html |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
SCITEPRESS – Science and Technology Publications |
publisher.none.fl_str_mv |
SCITEPRESS – Science and Technology Publications |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132976213131264 |