Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation

Detalhes bibliográficos
Autor(a) principal: Menezes, Carlos
Data de Publicação: 2015
Outros Autores: Rodrigues, Pedro, Resende, Rui Avelino, Lemos, José Alberto, Coelho, Pedro, Vieira, Bruna Cardoso, Serino, Josefina, Gonçalves, Rita, Tenedório, Paula
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.48560/rspo.6708
Resumo: Purpose: To evaluate the variation in keratometric index (KI) in eyes with keratoconus (KC), before and after the implantation of Intacs SK (Addition Technology Inc); Patients and Methods: 19 eyes with keratoconus, before and after Intacs-SK implantation (minimum follow-up of 6 months), and a control group of 26 healthy eyes were retrospectively studied. The anterior (ARC) and posterior radius of curvature (PRC), the ratio between them (ratio ARC/PRC) and the mean pupil power (MPP) were evaluated for the central 3 mm, using a tomographic system combining Scheimpflug photography and placido-disc analysis. The KI was calculated using the paraxial formula for thin lens, assuming the MPP (accessed by ray-tracing) as the true corneal power; Results: The mean values for ARC, PRC, ratio ARC/PRC and KI were, respectively, for the control group and for the keratoconic eyes before surgery: 7,71±0,30 e 6,78±0,52mm (p<0,05); 6,35±0,67 e 5,59±0,86mm (p<0,05), 1,236±0,220 e 1,234±0,159 (p>0,05); e 1,3317±0,0031 e 1,3321±0,0521 (p>0,05). In keratoconic eyes, after a mean follow-up of 9,47 months after Intacs-SK implantation, the ARC increased to 7,26±0,56mm (p<0,001), and the PRC increased to 5,63±0,95mm(p>0,05), which was not statistically significant. The mean ratio ARC/PRC increased to 1,314±0,190 (p<0,05) and the mean KI decreased to 1,3285±0,0817 (p<0,05); Conclusions: After Intacs-SK implantation, only the anterior cornea surface seems to be significantly flattened, with a consequent decrease in the KI. Thus, the standardized KI values may not be suitable for intra-ocular lens calculation in these patients. No statistical differences were found in the ratio ARC/PRC and in the KI between normal and keratoconic eyes.
id RCAP_cbd27fd2e5d60618cf1157298c15a5b8
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/6708
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Keratometric index variation in keratoconic eyes before and after Intacs-SK implantationArtigos OriginaisPurpose: To evaluate the variation in keratometric index (KI) in eyes with keratoconus (KC), before and after the implantation of Intacs SK (Addition Technology Inc); Patients and Methods: 19 eyes with keratoconus, before and after Intacs-SK implantation (minimum follow-up of 6 months), and a control group of 26 healthy eyes were retrospectively studied. The anterior (ARC) and posterior radius of curvature (PRC), the ratio between them (ratio ARC/PRC) and the mean pupil power (MPP) were evaluated for the central 3 mm, using a tomographic system combining Scheimpflug photography and placido-disc analysis. The KI was calculated using the paraxial formula for thin lens, assuming the MPP (accessed by ray-tracing) as the true corneal power; Results: The mean values for ARC, PRC, ratio ARC/PRC and KI were, respectively, for the control group and for the keratoconic eyes before surgery: 7,71±0,30 e 6,78±0,52mm (p<0,05); 6,35±0,67 e 5,59±0,86mm (p<0,05), 1,236±0,220 e 1,234±0,159 (p>0,05); e 1,3317±0,0031 e 1,3321±0,0521 (p>0,05). In keratoconic eyes, after a mean follow-up of 9,47 months after Intacs-SK implantation, the ARC increased to 7,26±0,56mm (p<0,001), and the PRC increased to 5,63±0,95mm(p>0,05), which was not statistically significant. The mean ratio ARC/PRC increased to 1,314±0,190 (p<0,05) and the mean KI decreased to 1,3285±0,0817 (p<0,05); Conclusions: After Intacs-SK implantation, only the anterior cornea surface seems to be significantly flattened, with a consequent decrease in the KI. Thus, the standardized KI values may not be suitable for intra-ocular lens calculation in these patients. No statistical differences were found in the ratio ARC/PRC and in the KI between normal and keratoconic eyes.Ajnet2015-12-25T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.48560/rspo.6708eng1646-69501646-6950Menezes, CarlosRodrigues, PedroResende, Rui AvelinoLemos, José AlbertoCoelho, PedroVieira, Bruna CardosoSerino, JosefinaGonçalves, RitaTenedório, Paulainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-22T17:05:51Zoai:ojs.revistas.rcaap.pt:article/6708Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:01:28.186711Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
title Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
spellingShingle Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
Menezes, Carlos
Artigos Originais
title_short Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
title_full Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
title_fullStr Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
title_full_unstemmed Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
title_sort Keratometric index variation in keratoconic eyes before and after Intacs-SK implantation
author Menezes, Carlos
author_facet Menezes, Carlos
Rodrigues, Pedro
Resende, Rui Avelino
Lemos, José Alberto
Coelho, Pedro
Vieira, Bruna Cardoso
Serino, Josefina
Gonçalves, Rita
Tenedório, Paula
author_role author
author2 Rodrigues, Pedro
Resende, Rui Avelino
Lemos, José Alberto
Coelho, Pedro
Vieira, Bruna Cardoso
Serino, Josefina
Gonçalves, Rita
Tenedório, Paula
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Menezes, Carlos
Rodrigues, Pedro
Resende, Rui Avelino
Lemos, José Alberto
Coelho, Pedro
Vieira, Bruna Cardoso
Serino, Josefina
Gonçalves, Rita
Tenedório, Paula
dc.subject.por.fl_str_mv Artigos Originais
topic Artigos Originais
description Purpose: To evaluate the variation in keratometric index (KI) in eyes with keratoconus (KC), before and after the implantation of Intacs SK (Addition Technology Inc); Patients and Methods: 19 eyes with keratoconus, before and after Intacs-SK implantation (minimum follow-up of 6 months), and a control group of 26 healthy eyes were retrospectively studied. The anterior (ARC) and posterior radius of curvature (PRC), the ratio between them (ratio ARC/PRC) and the mean pupil power (MPP) were evaluated for the central 3 mm, using a tomographic system combining Scheimpflug photography and placido-disc analysis. The KI was calculated using the paraxial formula for thin lens, assuming the MPP (accessed by ray-tracing) as the true corneal power; Results: The mean values for ARC, PRC, ratio ARC/PRC and KI were, respectively, for the control group and for the keratoconic eyes before surgery: 7,71±0,30 e 6,78±0,52mm (p<0,05); 6,35±0,67 e 5,59±0,86mm (p<0,05), 1,236±0,220 e 1,234±0,159 (p>0,05); e 1,3317±0,0031 e 1,3321±0,0521 (p>0,05). In keratoconic eyes, after a mean follow-up of 9,47 months after Intacs-SK implantation, the ARC increased to 7,26±0,56mm (p<0,001), and the PRC increased to 5,63±0,95mm(p>0,05), which was not statistically significant. The mean ratio ARC/PRC increased to 1,314±0,190 (p<0,05) and the mean KI decreased to 1,3285±0,0817 (p<0,05); Conclusions: After Intacs-SK implantation, only the anterior cornea surface seems to be significantly flattened, with a consequent decrease in the KI. Thus, the standardized KI values may not be suitable for intra-ocular lens calculation in these patients. No statistical differences were found in the ratio ARC/PRC and in the KI between normal and keratoconic eyes.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-25T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.48560/rspo.6708
url https://doi.org/10.48560/rspo.6708
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1646-6950
1646-6950
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Ajnet
publisher.none.fl_str_mv Ajnet
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130479691038720