Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research

Detalhes bibliográficos
Autor(a) principal: Silva, Neuza Filipa Botelho da
Data de Publicação: 2013
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/15864
Resumo: Background: Imagem e Espectroscopia por Ressonância Magnética são técnicas fenotípicas que permitem a caracterização não-invasiva da função cardíaca em roedores. No entanto, ao avaliar a função miocárdica, as fases do ciclo cardíaco onde ocorrem as taxas máximas de geração de pressão e relaxamento não são directamente acessíveis com técnicas de imagem. Esta informação está apenas disponível recorrendo a cateterismo, sendo que se trata de um procedimento invasivo e terminal em roedores. A Elastografia por Ressonância Magnética mensura a deformação de um tecido após a estimulação mecânica e tem o potencial de aceder de forma não-invasiva à pressão ventricular in vivo, como foi demonstrado com sucesso em porcos e corações humanos. Este projecto tem como objectivo a construção de um sistema que permite a excitação mecânica no interior do magnete com a adequada amplitude e gama de frequência, necessárias para experiências murinas. Metodologia: Foi necessário o desenvolvimento do hardware de Elastografia necessário à estimulação mecânica de tecidos, compatível com o sistema existente de manipulação dos animais. Sequências de Ressonância Magnética foram ainda implementadas e equipadas com um gradiente de sensibilização de movimento por forma a codificar a deformação das ondas de cisalhamento. O sistema de Elastografia bem como as sequências formam testados em géis de agarose com uma gama de frequências até aos 1,5 kHz de vibração, essenciais para dimensões do coração de ratos. Posteriormente, um gel de dois compartimentos com diferentes concentrações de agarose foi excitado utilizando a configuração de Elastografia. Finalmente, um rato morto foi submetido a exames de Elastografia por Ressonância Magnética. Resultados: Houve uma clara e uniforme penetração das ondas de cisalhamento nas experiências com géis de agarose. Todos os espectros mostraram um padrão de deslocamento de fase em toda a amostra, o que correspondeu à propagação das vibrações mecânicas. O gel de 0,5% de agarose deformou mais do que o gel de 1%, resultando num comprimento de onda mais curto que o comprimento de onda encontrado no gel mais rígido. Os resultados também mostram maior atenuação das ondas no gel de 1%, quer a 500 Hz quer a 1000 Hz de frequência de vibração, quando comparado com a propagação de ondas no gel de 0,5%. Na amostra de dois compartimentos, observou-se que as ondas penetraram não-uniformemente os dois compartimentos. Houve uma melhor propagação das ondas no gel de 0,5% de agarose do que no gel de 2%, resultando num comprimento de onda mais curto no gel menos rígido. No gel com maior rigidez não foi observável uma onda inteira numa única imagem, enquanto que no gel mais soft são observados seis ciclos completos de vibração. Nas experiências com o rato, verificou-se uma forte distinção dos tecidos aquando da passagem das vibrações. Os tecidos deformaram-se em função da sua rigidez que se traduziu em diferentes variações de fase no fígado e no coração. Conclusões: Neste projecto foi concebível um sistema bem-sucedido de estimulação mecânica dos tecidos. Foi qualitativamente demonstrado que a aplicação de excitação mecânica por ondas de cisalhamento pode ser um método para codificar propriedades mecânicas de um objecto heterogéneo. Assim, este projecto representou um enorme passo no desenvolvimento de uma técnica capaz de fazer medições de pressão ventricular em ratos.
id RCAP_cc7f3ca06f8d50a243909e636606750e
oai_identifier_str oai:repositorio.ucp.pt:10400.14/15864
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical researchDomínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e TecnologiasBackground: Imagem e Espectroscopia por Ressonância Magnética são técnicas fenotípicas que permitem a caracterização não-invasiva da função cardíaca em roedores. No entanto, ao avaliar a função miocárdica, as fases do ciclo cardíaco onde ocorrem as taxas máximas de geração de pressão e relaxamento não são directamente acessíveis com técnicas de imagem. Esta informação está apenas disponível recorrendo a cateterismo, sendo que se trata de um procedimento invasivo e terminal em roedores. A Elastografia por Ressonância Magnética mensura a deformação de um tecido após a estimulação mecânica e tem o potencial de aceder de forma não-invasiva à pressão ventricular in vivo, como foi demonstrado com sucesso em porcos e corações humanos. Este projecto tem como objectivo a construção de um sistema que permite a excitação mecânica no interior do magnete com a adequada amplitude e gama de frequência, necessárias para experiências murinas. Metodologia: Foi necessário o desenvolvimento do hardware de Elastografia necessário à estimulação mecânica de tecidos, compatível com o sistema existente de manipulação dos animais. Sequências de Ressonância Magnética foram ainda implementadas e equipadas com um gradiente de sensibilização de movimento por forma a codificar a deformação das ondas de cisalhamento. O sistema de Elastografia bem como as sequências formam testados em géis de agarose com uma gama de frequências até aos 1,5 kHz de vibração, essenciais para dimensões do coração de ratos. Posteriormente, um gel de dois compartimentos com diferentes concentrações de agarose foi excitado utilizando a configuração de Elastografia. Finalmente, um rato morto foi submetido a exames de Elastografia por Ressonância Magnética. Resultados: Houve uma clara e uniforme penetração das ondas de cisalhamento nas experiências com géis de agarose. Todos os espectros mostraram um padrão de deslocamento de fase em toda a amostra, o que correspondeu à propagação das vibrações mecânicas. O gel de 0,5% de agarose deformou mais do que o gel de 1%, resultando num comprimento de onda mais curto que o comprimento de onda encontrado no gel mais rígido. Os resultados também mostram maior atenuação das ondas no gel de 1%, quer a 500 Hz quer a 1000 Hz de frequência de vibração, quando comparado com a propagação de ondas no gel de 0,5%. Na amostra de dois compartimentos, observou-se que as ondas penetraram não-uniformemente os dois compartimentos. Houve uma melhor propagação das ondas no gel de 0,5% de agarose do que no gel de 2%, resultando num comprimento de onda mais curto no gel menos rígido. No gel com maior rigidez não foi observável uma onda inteira numa única imagem, enquanto que no gel mais soft são observados seis ciclos completos de vibração. Nas experiências com o rato, verificou-se uma forte distinção dos tecidos aquando da passagem das vibrações. Os tecidos deformaram-se em função da sua rigidez que se traduziu em diferentes variações de fase no fígado e no coração. Conclusões: Neste projecto foi concebível um sistema bem-sucedido de estimulação mecânica dos tecidos. Foi qualitativamente demonstrado que a aplicação de excitação mecânica por ondas de cisalhamento pode ser um método para codificar propriedades mecânicas de um objecto heterogéneo. Assim, este projecto representou um enorme passo no desenvolvimento de uma técnica capaz de fazer medições de pressão ventricular em ratos.Background: Magnetic Resonance Imaging (MRI) and Spectroscopy (MRS) are phenotyping techniques that allow for a non-invasive characterization of cardiac function in rodents. However, when assessing myocardial function, the isovolumic phases of the cardiac cycle are not directly accessible to imaging techniques, yet this is where maximal rates of pressure generation and relaxation occur. This type of information is only available using LV catheterization, which in rodents is an invasive and terminal procedure, requiring new experimental groups every time-point. Magnetic Resonance Elastography (MRE) measures shear deformation following mechanical tissue stimulation and has the potential to non-invasively access ventricular pressure in vivo, as successfully demonstrated in pig and human hearts. Therefore, this project aims to build a setup, which allows for mechanical stimulations inside the magnet with the appropriate amplitude and frequency range required for murine experiments. Methodology: Core to this project was the development of the MRE hardware required for the mechanical tissue stimulation and compatible with the existing animal handling system. MRI sequences needed to be implemented to equip them with motion-sensitizing gradient to encode shear deformation. In order to validate the MRE setup and the MRI sequences, phantoms of different concentrations of agarose were excited over a wide range of frequencies. The frequencies ranged from hundreds of Hz up to 1.5 kHz. MRE experiments were subsequently performed on a two-compartment phantom with different concentrations of agarose. Finally, a dead mouse was subjected to MRE examinations. Results: There was a clear uniform penetration of shear waves in phantom experiments. All phantoms demonstrated a pattern of phase shifts across the sample, which corresponded to propagation of mechanical vibrations. The gel of 0.5% agarose deformed more than the 1% agarose gel, resulting in a wavelength shorter than the wavelength found in stiffer gel. The results also show higher attenuation of shear waves in 1% agarose gel, either at 500 Hz or 1000 Hz of vibration frequency, when compared with the propagation of waves in 0.5% agarose gel. In the two-compartment phantom, shear waves penetrated non-uniformly the phantom. There was a better propagation of waves in the 0.5% gel than in the 2% one, resulting in a shorter wavelength in the softer gel than the rigid one. In the gel with higher level of stiffness the wavelength exceeded the dimensions of the gel while in the softer gel were observed six complete vibration cycles. In the mouse experiments, there was a strong tissue distinction when vibrations passed through them. The tissues deformed depending on their rigidity which translated into different spins phase variations either in the liver or in the heart. Conclusions: A setup to provide tissue mechanical stimulation in a small bore pre-clinical MR system was successfully developed. It was qualitatively demonstrated that the application of shear wave mechanical excitation may be a method to encode mechanical properties of a heterogeneous object. Thus, this project represented a major step in the ability to develop a technique for indirect LV pressure measurements in mice.Schneider, JurgenMaguire, MahonVeritati - Repositório Institucional da Universidade Católica PortuguesaSilva, Neuza Filipa Botelho da2014-12-03T15:46:03Z2013-11-1120132013-11-11T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.14/15864TID:202728161enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-03T01:39:42Zoai:repositorio.ucp.pt:10400.14/15864Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:13:10.828260Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
title Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
spellingShingle Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
Silva, Neuza Filipa Botelho da
Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias
title_short Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
title_full Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
title_fullStr Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
title_full_unstemmed Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
title_sort Pilot study on the feasibility of replacing invasive heart pressure measurements with non-invasivemagnetic resonance elastography as a way to reduce rodent numbers in pre-clinical research
author Silva, Neuza Filipa Botelho da
author_facet Silva, Neuza Filipa Botelho da
author_role author
dc.contributor.none.fl_str_mv Schneider, Jurgen
Maguire, Mahon
Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Silva, Neuza Filipa Botelho da
dc.subject.por.fl_str_mv Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias
topic Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias
description Background: Imagem e Espectroscopia por Ressonância Magnética são técnicas fenotípicas que permitem a caracterização não-invasiva da função cardíaca em roedores. No entanto, ao avaliar a função miocárdica, as fases do ciclo cardíaco onde ocorrem as taxas máximas de geração de pressão e relaxamento não são directamente acessíveis com técnicas de imagem. Esta informação está apenas disponível recorrendo a cateterismo, sendo que se trata de um procedimento invasivo e terminal em roedores. A Elastografia por Ressonância Magnética mensura a deformação de um tecido após a estimulação mecânica e tem o potencial de aceder de forma não-invasiva à pressão ventricular in vivo, como foi demonstrado com sucesso em porcos e corações humanos. Este projecto tem como objectivo a construção de um sistema que permite a excitação mecânica no interior do magnete com a adequada amplitude e gama de frequência, necessárias para experiências murinas. Metodologia: Foi necessário o desenvolvimento do hardware de Elastografia necessário à estimulação mecânica de tecidos, compatível com o sistema existente de manipulação dos animais. Sequências de Ressonância Magnética foram ainda implementadas e equipadas com um gradiente de sensibilização de movimento por forma a codificar a deformação das ondas de cisalhamento. O sistema de Elastografia bem como as sequências formam testados em géis de agarose com uma gama de frequências até aos 1,5 kHz de vibração, essenciais para dimensões do coração de ratos. Posteriormente, um gel de dois compartimentos com diferentes concentrações de agarose foi excitado utilizando a configuração de Elastografia. Finalmente, um rato morto foi submetido a exames de Elastografia por Ressonância Magnética. Resultados: Houve uma clara e uniforme penetração das ondas de cisalhamento nas experiências com géis de agarose. Todos os espectros mostraram um padrão de deslocamento de fase em toda a amostra, o que correspondeu à propagação das vibrações mecânicas. O gel de 0,5% de agarose deformou mais do que o gel de 1%, resultando num comprimento de onda mais curto que o comprimento de onda encontrado no gel mais rígido. Os resultados também mostram maior atenuação das ondas no gel de 1%, quer a 500 Hz quer a 1000 Hz de frequência de vibração, quando comparado com a propagação de ondas no gel de 0,5%. Na amostra de dois compartimentos, observou-se que as ondas penetraram não-uniformemente os dois compartimentos. Houve uma melhor propagação das ondas no gel de 0,5% de agarose do que no gel de 2%, resultando num comprimento de onda mais curto no gel menos rígido. No gel com maior rigidez não foi observável uma onda inteira numa única imagem, enquanto que no gel mais soft são observados seis ciclos completos de vibração. Nas experiências com o rato, verificou-se uma forte distinção dos tecidos aquando da passagem das vibrações. Os tecidos deformaram-se em função da sua rigidez que se traduziu em diferentes variações de fase no fígado e no coração. Conclusões: Neste projecto foi concebível um sistema bem-sucedido de estimulação mecânica dos tecidos. Foi qualitativamente demonstrado que a aplicação de excitação mecânica por ondas de cisalhamento pode ser um método para codificar propriedades mecânicas de um objecto heterogéneo. Assim, este projecto representou um enorme passo no desenvolvimento de uma técnica capaz de fazer medições de pressão ventricular em ratos.
publishDate 2013
dc.date.none.fl_str_mv 2013-11-11
2013
2013-11-11T00:00:00Z
2014-12-03T15:46:03Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/15864
TID:202728161
url http://hdl.handle.net/10400.14/15864
identifier_str_mv TID:202728161
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131809625145344