Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/31200 |
Resumo: | Self-tapping screws (STS) have been proclaimed as the easiest solution for structural timber connections, in special for cross laminated timber (CLT) constructions. In order to understand deeply the composite model “CLT-STS”, an experimental campaign which comprised 270 withdrawal tests was carried out. Maximum withdrawal load capacity of self-tapping screws inserted in plane side of a three layered CLT panel was evaluated considering three main parameters: moisture levels of CLT (i), number of gaps (ii) and the width of gaps (iii). Regarding (i), connections were tested with CLT at 8%, 12% and 18% of moisture content. Concerning (ii) and (iii), different test configurations with 1, 2 and 3 gaps, with 0 or 4mm, were tested. The influences of moisture content and number of gaps were modeled. Further a correlation between test results and a prediction model developed by Uibel and Blaß (2007) has been proposed. |
id |
RCAP_cc814bd54eae9ec38079f5976e010835 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/31200 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLTSelf-tapping screws (STS) have been proclaimed as the easiest solution for structural timber connections, in special for cross laminated timber (CLT) constructions. In order to understand deeply the composite model “CLT-STS”, an experimental campaign which comprised 270 withdrawal tests was carried out. Maximum withdrawal load capacity of self-tapping screws inserted in plane side of a three layered CLT panel was evaluated considering three main parameters: moisture levels of CLT (i), number of gaps (ii) and the width of gaps (iii). Regarding (i), connections were tested with CLT at 8%, 12% and 18% of moisture content. Concerning (ii) and (iii), different test configurations with 1, 2 and 3 gaps, with 0 or 4mm, were tested. The influences of moisture content and number of gaps were modeled. Further a correlation between test results and a prediction model developed by Uibel and Blaß (2007) has been proposed.Universidade do MinhoSilva, Catarina V.Ringhofer, A.Branco, Jorge M.Lourenço, Paulo B.Schickhofer, G.2014-10-152014-10-15T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/31200enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-11T04:27:15Zoai:repositorium.sdum.uminho.pt:1822/31200Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-11T04:27:15Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
title |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
spellingShingle |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT Silva, Catarina V. |
title_short |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
title_full |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
title_fullStr |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
title_full_unstemmed |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
title_sort |
Influence of moisture content and gaps on the withdrawal resistance of self tapping screws in CLT |
author |
Silva, Catarina V. |
author_facet |
Silva, Catarina V. Ringhofer, A. Branco, Jorge M. Lourenço, Paulo B. Schickhofer, G. |
author_role |
author |
author2 |
Ringhofer, A. Branco, Jorge M. Lourenço, Paulo B. Schickhofer, G. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Silva, Catarina V. Ringhofer, A. Branco, Jorge M. Lourenço, Paulo B. Schickhofer, G. |
description |
Self-tapping screws (STS) have been proclaimed as the easiest solution for structural timber connections, in special for cross laminated timber (CLT) constructions. In order to understand deeply the composite model “CLT-STS”, an experimental campaign which comprised 270 withdrawal tests was carried out. Maximum withdrawal load capacity of self-tapping screws inserted in plane side of a three layered CLT panel was evaluated considering three main parameters: moisture levels of CLT (i), number of gaps (ii) and the width of gaps (iii). Regarding (i), connections were tested with CLT at 8%, 12% and 18% of moisture content. Concerning (ii) and (iii), different test configurations with 1, 2 and 3 gaps, with 0 or 4mm, were tested. The influences of moisture content and number of gaps were modeled. Further a correlation between test results and a prediction model developed by Uibel and Blaß (2007) has been proposed. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-10-15 2014-10-15T00:00:00Z |
dc.type.driver.fl_str_mv |
conference paper |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/31200 |
url |
http://hdl.handle.net/1822/31200 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817544314766491648 |