Reconfigurable power quality analyser

Detalhes bibliográficos
Autor(a) principal: Fazendeiro, João Fernando de Aguiar
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.8/2528
Resumo: Electronic power supplies are found in almost all electrical equipment. They are sensitive to power quality disturbances but they themselves are causers of interference. This becomes more prominent with their wider use which means that these disturbances have a tendency to aggravate in future. One of the results will be that additional losses will occur and end-users will also be penalised for it by paying more. There is a need to revert this tendency also in an effort to help lower pollution. Another consequence of disturbances is the added difficulty that power grid operators will have to maintain the network stable. Everyone would therefore benefit from more efficient electricity consumption. A power quality disturbance can be measured with a power quality analyser to help the technician find its cause. This is the first step to finding a solution to resolve the disturbance. The objective of this project was to implement digital signal processing algorithms on a FPGA for the analysis of power quality disturbances. The motive for choosing the FPGA was that it allowed a processor, used for lower demanding processing tasks, and dedicated hardware, used for time-critical operations, to be integrated into a single integrated circuit. The implementation of these algorithms in dedicated hardware permitted obtaining high-resolution measurements and the exploitation of parallelism to increase the quantity of information available to the user. The FPGA is a versatile component, ideal to implement the reconfigurable power quality analyser that is upgradable in future. The project resulted in the successful measurement of the fundamental frequency and the magnitude of the signal at the input. The device was able to detect and measure harmonic and inter-harmonic components. Positive and negative peak values were measured and the root mean square value both for full-cycle and half-cycle were calculated making stationary signal variation evaluation possible. Time aggregation of values was also done. The generation of an internal signal made it possible for the comparison with the input signal, resulting in event isolation for further verification and classification by the controller.
id RCAP_cead71b0096b75825022f60b46996f2c
oai_identifier_str oai:iconline.ipleiria.pt:10400.8/2528
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Reconfigurable power quality analyserEnergiaFPGAMonitorPerturbaçõesQualidadeVariaçõesDomínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e InformáticaElectronic power supplies are found in almost all electrical equipment. They are sensitive to power quality disturbances but they themselves are causers of interference. This becomes more prominent with their wider use which means that these disturbances have a tendency to aggravate in future. One of the results will be that additional losses will occur and end-users will also be penalised for it by paying more. There is a need to revert this tendency also in an effort to help lower pollution. Another consequence of disturbances is the added difficulty that power grid operators will have to maintain the network stable. Everyone would therefore benefit from more efficient electricity consumption. A power quality disturbance can be measured with a power quality analyser to help the technician find its cause. This is the first step to finding a solution to resolve the disturbance. The objective of this project was to implement digital signal processing algorithms on a FPGA for the analysis of power quality disturbances. The motive for choosing the FPGA was that it allowed a processor, used for lower demanding processing tasks, and dedicated hardware, used for time-critical operations, to be integrated into a single integrated circuit. The implementation of these algorithms in dedicated hardware permitted obtaining high-resolution measurements and the exploitation of parallelism to increase the quantity of information available to the user. The FPGA is a versatile component, ideal to implement the reconfigurable power quality analyser that is upgradable in future. The project resulted in the successful measurement of the fundamental frequency and the magnitude of the signal at the input. The device was able to detect and measure harmonic and inter-harmonic components. Positive and negative peak values were measured and the root mean square value both for full-cycle and half-cycle were calculated making stationary signal variation evaluation possible. Time aggregation of values was also done. The generation of an internal signal made it possible for the comparison with the input signal, resulting in event isolation for further verification and classification by the controller.Figueiredo, Mónica Jorge Carvalho deOliveira, Filipe Tadeu SoaresIC-OnlineFazendeiro, João Fernando de Aguiar2017-03-17T15:39:55Z2015-05-272015-05-27T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.8/2528TID:201649519enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-17T15:45:19Zoai:iconline.ipleiria.pt:10400.8/2528Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:46:51.032384Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Reconfigurable power quality analyser
title Reconfigurable power quality analyser
spellingShingle Reconfigurable power quality analyser
Fazendeiro, João Fernando de Aguiar
Energia
FPGA
Monitor
Perturbações
Qualidade
Variações
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
title_short Reconfigurable power quality analyser
title_full Reconfigurable power quality analyser
title_fullStr Reconfigurable power quality analyser
title_full_unstemmed Reconfigurable power quality analyser
title_sort Reconfigurable power quality analyser
author Fazendeiro, João Fernando de Aguiar
author_facet Fazendeiro, João Fernando de Aguiar
author_role author
dc.contributor.none.fl_str_mv Figueiredo, Mónica Jorge Carvalho de
Oliveira, Filipe Tadeu Soares
IC-Online
dc.contributor.author.fl_str_mv Fazendeiro, João Fernando de Aguiar
dc.subject.por.fl_str_mv Energia
FPGA
Monitor
Perturbações
Qualidade
Variações
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
topic Energia
FPGA
Monitor
Perturbações
Qualidade
Variações
Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
description Electronic power supplies are found in almost all electrical equipment. They are sensitive to power quality disturbances but they themselves are causers of interference. This becomes more prominent with their wider use which means that these disturbances have a tendency to aggravate in future. One of the results will be that additional losses will occur and end-users will also be penalised for it by paying more. There is a need to revert this tendency also in an effort to help lower pollution. Another consequence of disturbances is the added difficulty that power grid operators will have to maintain the network stable. Everyone would therefore benefit from more efficient electricity consumption. A power quality disturbance can be measured with a power quality analyser to help the technician find its cause. This is the first step to finding a solution to resolve the disturbance. The objective of this project was to implement digital signal processing algorithms on a FPGA for the analysis of power quality disturbances. The motive for choosing the FPGA was that it allowed a processor, used for lower demanding processing tasks, and dedicated hardware, used for time-critical operations, to be integrated into a single integrated circuit. The implementation of these algorithms in dedicated hardware permitted obtaining high-resolution measurements and the exploitation of parallelism to increase the quantity of information available to the user. The FPGA is a versatile component, ideal to implement the reconfigurable power quality analyser that is upgradable in future. The project resulted in the successful measurement of the fundamental frequency and the magnitude of the signal at the input. The device was able to detect and measure harmonic and inter-harmonic components. Positive and negative peak values were measured and the root mean square value both for full-cycle and half-cycle were calculated making stationary signal variation evaluation possible. Time aggregation of values was also done. The generation of an internal signal made it possible for the comparison with the input signal, resulting in event isolation for further verification and classification by the controller.
publishDate 2015
dc.date.none.fl_str_mv 2015-05-27
2015-05-27T00:00:00Z
2017-03-17T15:39:55Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.8/2528
TID:201649519
url http://hdl.handle.net/10400.8/2528
identifier_str_mv TID:201649519
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136963028058112