Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://hdl.handle.net/1822/25076 |
Resumo: | This study discusses the retention of Ni(II) by Arthrobacter viscosus supported on zeolite 13 X in batch mode and in continuous mode, at laboratory scale and at pilot scale. The maximum adsorption capacities of 28.37, 20.21 and 11.13 mg/g were recorded for lab scale batch, for continuous lab scale minicolumns and for pilot scale bioreactors, respectively. The Sips isotherm and pseudo second order kinetics described well the observations registered in batch assays. The Adams–Bohart, Thomas and Yoon–Nelson models were applied to data obtained with the pilot scale bioreactor and a good fit was reached for Adams–Bohart and for Yoon–Nelson models. A fed-batch was performed at lab scale and the applicability of the biofilm in continuous mode for the described purpose was confirmed. The sorption mechanism was investigated in detail through FTIR, SEM and EDX analyses. |
id |
RCAP_d3106ba8eb4d8f73afd1e038581bb576 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/25076 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scaleBacteriaBioreactorIsothermsKineticsNickelScience & TechnologyThis study discusses the retention of Ni(II) by Arthrobacter viscosus supported on zeolite 13 X in batch mode and in continuous mode, at laboratory scale and at pilot scale. The maximum adsorption capacities of 28.37, 20.21 and 11.13 mg/g were recorded for lab scale batch, for continuous lab scale minicolumns and for pilot scale bioreactors, respectively. The Sips isotherm and pseudo second order kinetics described well the observations registered in batch assays. The Adams–Bohart, Thomas and Yoon–Nelson models were applied to data obtained with the pilot scale bioreactor and a good fit was reached for Adams–Bohart and for Yoon–Nelson models. A fed-batch was performed at lab scale and the applicability of the biofilm in continuous mode for the described purpose was confirmed. The sorption mechanism was investigated in detail through FTIR, SEM and EDX analyses.The authors would like to gratefully acknowledge the financial support of this project by the Fundacao para a Ciencia e Tecnologia, Ministerio da Ciencia e Tecnologia, Portugal and co- funding by FSE (programme QREN - POPH). Cristina Quintelas thanks FCT for a Post-Doc grant (SFRH/BPD/32113/ 2006).Elsevier 1Elsevier BVUniversidade do MinhoQuintelas, C.Pereira, RicardoKaplan, EcemTavares, M. T.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/25076eng0960-85240960-852410.1016/j.biortech.2013.05.059info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-11-16T01:26:20Zoai:repositorium.sdum.uminho.pt:1822/25076Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-11-16T01:26:20Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
title |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
spellingShingle |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale Quintelas, C. Bacteria Bioreactor Isotherms Kinetics Nickel Science & Technology |
title_short |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
title_full |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
title_fullStr |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
title_full_unstemmed |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
title_sort |
Removal of Ni(II) from aqueous solutions by an Arthrobacter viscosus biofilm supported on zeolite: from laboratory to pilot scale |
author |
Quintelas, C. |
author_facet |
Quintelas, C. Pereira, Ricardo Kaplan, Ecem Tavares, M. T. |
author_role |
author |
author2 |
Pereira, Ricardo Kaplan, Ecem Tavares, M. T. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Quintelas, C. Pereira, Ricardo Kaplan, Ecem Tavares, M. T. |
dc.subject.por.fl_str_mv |
Bacteria Bioreactor Isotherms Kinetics Nickel Science & Technology |
topic |
Bacteria Bioreactor Isotherms Kinetics Nickel Science & Technology |
description |
This study discusses the retention of Ni(II) by Arthrobacter viscosus supported on zeolite 13 X in batch mode and in continuous mode, at laboratory scale and at pilot scale. The maximum adsorption capacities of 28.37, 20.21 and 11.13 mg/g were recorded for lab scale batch, for continuous lab scale minicolumns and for pilot scale bioreactors, respectively. The Sips isotherm and pseudo second order kinetics described well the observations registered in batch assays. The Adams–Bohart, Thomas and Yoon–Nelson models were applied to data obtained with the pilot scale bioreactor and a good fit was reached for Adams–Bohart and for Yoon–Nelson models. A fed-batch was performed at lab scale and the applicability of the biofilm in continuous mode for the described purpose was confirmed. The sorption mechanism was investigated in detail through FTIR, SEM and EDX analyses. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/25076 |
url |
https://hdl.handle.net/1822/25076 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0960-8524 0960-8524 10.1016/j.biortech.2013.05.059 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier 1 Elsevier BV |
publisher.none.fl_str_mv |
Elsevier 1 Elsevier BV |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817544543321456640 |