Feasibility of routine respiratory function testing in preschool children
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Livro |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.26/5408 |
Resumo: | INTRODUCTION: The assessment of respiratory function in preschool children, which has recently been attracting considerable interest, has several methodological particularities. Whether this is feasible in clinical practice with large groups of patients still needs to be investigated. AIM: To assess the feasibility of pulmonary function testing in preschool children in clinical practice, and report the degree of success achieved according to age. METHODS: Retrospective analysis of lung function tests performed in children from 2 to 6 years old at the respiratory function laboratory of CUF Descobertas Hospital between September 2006 and August 2011. Whole-body pletismography without occlusion for specific airway resistance (sRaw) assessment and animated spirometry were performed using the equipment Jaeger 4.65 (Viasys Healthcare), before and after 400 μg of inhaled salbutamol via a spacer device. The research fulfilled international criteria (ATS/ERS) for acceptability and reproducibility. RESULTS: Of 1,239 lung function tests performed, 1,092 (88%) had acceptable and reproducible criteria for spirometry (children with a mean age of 4.3±0.91 years; 60.7% male), and 979 (79%) for sRaw measurement. We were able to report FEV(1) in 801 (65%) tests (children with a mean age of 4.5±0.89 years). In 23 (2%) tests it was only possible to report FEV(0.5) (children with a mean age of 3.5±0.67 years) and in 268 (22%) only FEV(0.75) (children with a mean age of 4.0±0.89 years). CONCLUSION: Spirometry and sRaw assessment in preschool children can be used in clinical practice, with an increasing success rate as children get older. Reporting maneuvers of 0.5 or 0.75 seconds facilitates spirometric evaluation in a larger number of children. |
id |
RCAP_dd4dd1d08b4cbf6c18ad5c84a65f674a |
---|---|
oai_identifier_str |
oai:comum.rcaap.pt:10400.26/5408 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Feasibility of routine respiratory function testing in preschool childrenExequibilidade do estudo funcional respiratório em idade pré-escolar na prática clínicaChildRespiratory Function TestsCriançaTestes de Função RespiratóriaINTRODUCTION: The assessment of respiratory function in preschool children, which has recently been attracting considerable interest, has several methodological particularities. Whether this is feasible in clinical practice with large groups of patients still needs to be investigated. AIM: To assess the feasibility of pulmonary function testing in preschool children in clinical practice, and report the degree of success achieved according to age. METHODS: Retrospective analysis of lung function tests performed in children from 2 to 6 years old at the respiratory function laboratory of CUF Descobertas Hospital between September 2006 and August 2011. Whole-body pletismography without occlusion for specific airway resistance (sRaw) assessment and animated spirometry were performed using the equipment Jaeger 4.65 (Viasys Healthcare), before and after 400 μg of inhaled salbutamol via a spacer device. The research fulfilled international criteria (ATS/ERS) for acceptability and reproducibility. RESULTS: Of 1,239 lung function tests performed, 1,092 (88%) had acceptable and reproducible criteria for spirometry (children with a mean age of 4.3±0.91 years; 60.7% male), and 979 (79%) for sRaw measurement. We were able to report FEV(1) in 801 (65%) tests (children with a mean age of 4.5±0.89 years). In 23 (2%) tests it was only possible to report FEV(0.5) (children with a mean age of 3.5±0.67 years) and in 268 (22%) only FEV(0.75) (children with a mean age of 4.0±0.89 years). CONCLUSION: Spirometry and sRaw assessment in preschool children can be used in clinical practice, with an increasing success rate as children get older. Reporting maneuvers of 0.5 or 0.75 seconds facilitates spirometric evaluation in a larger number of children.Sociedade Portuguesa de PneumologiaRepositório ComumSantos, NAlmeida, ICouto, MMorais-Almeida, MBorrego, LM2014-01-21T23:00:13Z20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttp://hdl.handle.net/10400.26/5408engRev Port Pneumol. 2013;19(1):38-41.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-12-20T14:24:55Zoai:comum.rcaap.pt:10400.26/5408Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:22:33.348128Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Feasibility of routine respiratory function testing in preschool children Exequibilidade do estudo funcional respiratório em idade pré-escolar na prática clínica |
title |
Feasibility of routine respiratory function testing in preschool children |
spellingShingle |
Feasibility of routine respiratory function testing in preschool children Santos, N Child Respiratory Function Tests Criança Testes de Função Respiratória |
title_short |
Feasibility of routine respiratory function testing in preschool children |
title_full |
Feasibility of routine respiratory function testing in preschool children |
title_fullStr |
Feasibility of routine respiratory function testing in preschool children |
title_full_unstemmed |
Feasibility of routine respiratory function testing in preschool children |
title_sort |
Feasibility of routine respiratory function testing in preschool children |
author |
Santos, N |
author_facet |
Santos, N Almeida, I Couto, M Morais-Almeida, M Borrego, LM |
author_role |
author |
author2 |
Almeida, I Couto, M Morais-Almeida, M Borrego, LM |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Repositório Comum |
dc.contributor.author.fl_str_mv |
Santos, N Almeida, I Couto, M Morais-Almeida, M Borrego, LM |
dc.subject.por.fl_str_mv |
Child Respiratory Function Tests Criança Testes de Função Respiratória |
topic |
Child Respiratory Function Tests Criança Testes de Função Respiratória |
description |
INTRODUCTION: The assessment of respiratory function in preschool children, which has recently been attracting considerable interest, has several methodological particularities. Whether this is feasible in clinical practice with large groups of patients still needs to be investigated. AIM: To assess the feasibility of pulmonary function testing in preschool children in clinical practice, and report the degree of success achieved according to age. METHODS: Retrospective analysis of lung function tests performed in children from 2 to 6 years old at the respiratory function laboratory of CUF Descobertas Hospital between September 2006 and August 2011. Whole-body pletismography without occlusion for specific airway resistance (sRaw) assessment and animated spirometry were performed using the equipment Jaeger 4.65 (Viasys Healthcare), before and after 400 μg of inhaled salbutamol via a spacer device. The research fulfilled international criteria (ATS/ERS) for acceptability and reproducibility. RESULTS: Of 1,239 lung function tests performed, 1,092 (88%) had acceptable and reproducible criteria for spirometry (children with a mean age of 4.3±0.91 years; 60.7% male), and 979 (79%) for sRaw measurement. We were able to report FEV(1) in 801 (65%) tests (children with a mean age of 4.5±0.89 years). In 23 (2%) tests it was only possible to report FEV(0.5) (children with a mean age of 3.5±0.67 years) and in 268 (22%) only FEV(0.75) (children with a mean age of 4.0±0.89 years). CONCLUSION: Spirometry and sRaw assessment in preschool children can be used in clinical practice, with an increasing success rate as children get older. Reporting maneuvers of 0.5 or 0.75 seconds facilitates spirometric evaluation in a larger number of children. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z 2014-01-21T23:00:13Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/book |
format |
book |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.26/5408 |
url |
http://hdl.handle.net/10400.26/5408 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Rev Port Pneumol. 2013;19(1):38-41. |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Pneumologia |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Pneumologia |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817553760942030848 |