Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10773/12673 |
Resumo: | The present paper analyses the design procedure and its impact on seismic safety of the structures. For this, a representative reinforced concrete frame building (WDS) is designed and the results are compared with similar buildings detailed with: i) Current Construction Practices (CCP); ii) the Nepal Building Code (NBC) and iii) the Modified Nepal Building Code (NBC+) recommendations. The seismic performance evaluation is done with global strength, inter-storey drift and displacement of the structures. Likewise, the sensitivity of the structural and geometrical parameters of the RC frame building is studied through nonlinear analysis. The study parameters considered for parametric analysis are column size, beam size, inter-storey height, bay length, bay width, and compressive strength of concrete. The results show that the influence on the structural behaviour, particularly by variation in column size and inter-storey height. Additionally, the influence of the seismic zone factor on reinforcement demand of the structure is studied. The result shows that structures designed for high to medium seismic hazard demands double the reinforcement in beams compared to structures in low seismic zone. |
id |
RCAP_e0eab235f86dd44a4e493f2dcf99d0ad |
---|---|
oai_identifier_str |
oai:ria.ua.pt:10773/12673 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safetyRC buildingsStatistical analysisAdaptive pushoverSeismic performanceSensitivity analysisThe present paper analyses the design procedure and its impact on seismic safety of the structures. For this, a representative reinforced concrete frame building (WDS) is designed and the results are compared with similar buildings detailed with: i) Current Construction Practices (CCP); ii) the Nepal Building Code (NBC) and iii) the Modified Nepal Building Code (NBC+) recommendations. The seismic performance evaluation is done with global strength, inter-storey drift and displacement of the structures. Likewise, the sensitivity of the structural and geometrical parameters of the RC frame building is studied through nonlinear analysis. The study parameters considered for parametric analysis are column size, beam size, inter-storey height, bay length, bay width, and compressive strength of concrete. The results show that the influence on the structural behaviour, particularly by variation in column size and inter-storey height. Additionally, the influence of the seismic zone factor on reinforcement demand of the structure is studied. The result shows that structures designed for high to medium seismic hazard demands double the reinforcement in beams compared to structures in low seismic zone.Multi-Science Publishing2018-07-20T14:00:46Z2014-10-01T00:00:00Z2014-102015-03-30T16:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/12673eng1369-433210.1260/1369-4332.17.10.1419Chaulagain, HemchandraRodrigues, HugoSpacone, EnricoVarum, Humbertoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-22T11:23:08Zoai:ria.ua.pt:10773/12673Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:48:47.609835Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
title |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
spellingShingle |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety Chaulagain, Hemchandra RC buildings Statistical analysis Adaptive pushover Seismic performance Sensitivity analysis |
title_short |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
title_full |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
title_fullStr |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
title_full_unstemmed |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
title_sort |
Design procedures of reinforced concrete framed buildings in Nepal and its impact on seismic safety |
author |
Chaulagain, Hemchandra |
author_facet |
Chaulagain, Hemchandra Rodrigues, Hugo Spacone, Enrico Varum, Humberto |
author_role |
author |
author2 |
Rodrigues, Hugo Spacone, Enrico Varum, Humberto |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Chaulagain, Hemchandra Rodrigues, Hugo Spacone, Enrico Varum, Humberto |
dc.subject.por.fl_str_mv |
RC buildings Statistical analysis Adaptive pushover Seismic performance Sensitivity analysis |
topic |
RC buildings Statistical analysis Adaptive pushover Seismic performance Sensitivity analysis |
description |
The present paper analyses the design procedure and its impact on seismic safety of the structures. For this, a representative reinforced concrete frame building (WDS) is designed and the results are compared with similar buildings detailed with: i) Current Construction Practices (CCP); ii) the Nepal Building Code (NBC) and iii) the Modified Nepal Building Code (NBC+) recommendations. The seismic performance evaluation is done with global strength, inter-storey drift and displacement of the structures. Likewise, the sensitivity of the structural and geometrical parameters of the RC frame building is studied through nonlinear analysis. The study parameters considered for parametric analysis are column size, beam size, inter-storey height, bay length, bay width, and compressive strength of concrete. The results show that the influence on the structural behaviour, particularly by variation in column size and inter-storey height. Additionally, the influence of the seismic zone factor on reinforcement demand of the structure is studied. The result shows that structures designed for high to medium seismic hazard demands double the reinforcement in beams compared to structures in low seismic zone. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-10-01T00:00:00Z 2014-10 2015-03-30T16:00:00Z 2018-07-20T14:00:46Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10773/12673 |
url |
http://hdl.handle.net/10773/12673 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1369-4332 10.1260/1369-4332.17.10.1419 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Multi-Science Publishing |
publisher.none.fl_str_mv |
Multi-Science Publishing |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137538840985600 |