Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates

Detalhes bibliográficos
Autor(a) principal: Ferreira, Francisca T.S.M.
Data de Publicação: 2020
Outros Autores: Mesquita, Letícia S., Mesquita, Raquel B.R., Rangel, António O.S.S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/31611
Resumo: Phosphate is a well-known contaminant and its content is an indicator of water quality, so it is important to have an efficient monitoring of the soil leaching process. In this work, an automatic, low cost flow analysis method, capable of real-time monitoring of the soil leaching processes using spectrophotometric detection, based on the molybdenum blue reaction, was developed. The developed methodology for phosphate determination was based on the molybdenum blue reaction and includes an on-line solid phase extraction (SPE) step, involving an AG1-X8 anionic exchange sorbent. The described SI method enabled phosphate determination within a wide range, 1–80 µM, with a detection limit of 0.52 µM. It was successfully applied to leachates from laboratory scale soil columns (LSSC) and one sample analysis was carried out in triplicate, in less than 10 minutes.
id RCAP_e347533868316b10e0f05f2b37f2605f
oai_identifier_str oai:repositorio.ucp.pt:10400.14/31611
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachatesPhosphateFlow analysisAG1-X8 anionic exchange resinMolybdenum blue reactionGroundwater contaminationPhosphate is a well-known contaminant and its content is an indicator of water quality, so it is important to have an efficient monitoring of the soil leaching process. In this work, an automatic, low cost flow analysis method, capable of real-time monitoring of the soil leaching processes using spectrophotometric detection, based on the molybdenum blue reaction, was developed. The developed methodology for phosphate determination was based on the molybdenum blue reaction and includes an on-line solid phase extraction (SPE) step, involving an AG1-X8 anionic exchange sorbent. The described SI method enabled phosphate determination within a wide range, 1–80 µM, with a detection limit of 0.52 µM. It was successfully applied to leachates from laboratory scale soil columns (LSSC) and one sample analysis was carried out in triplicate, in less than 10 minutes.ElsevierVeritati - Repositório Institucional da Universidade Católica PortuguesaFerreira, Francisca T.S.M.Mesquita, Letícia S.Mesquita, Raquel B.R.Rangel, António O.S.S.2021-01-08T16:11:31Z20202020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.14/31611engFerreira, F. T.S.M., Mesquita, L.S., Mesquita, R.B.R., Rangel, A.O.S.S. (2020). Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates. Talanta Open, 2:1000152666-831910.1016/j.talo.2020.100015info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-12T17:37:09Zoai:repositorio.ucp.pt:10400.14/31611Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:25:29.926688Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
title Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
spellingShingle Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
Ferreira, Francisca T.S.M.
Phosphate
Flow analysis
AG1-X8 anionic exchange resin
Molybdenum blue reaction
Groundwater contamination
title_short Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
title_full Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
title_fullStr Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
title_full_unstemmed Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
title_sort Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates
author Ferreira, Francisca T.S.M.
author_facet Ferreira, Francisca T.S.M.
Mesquita, Letícia S.
Mesquita, Raquel B.R.
Rangel, António O.S.S.
author_role author
author2 Mesquita, Letícia S.
Mesquita, Raquel B.R.
Rangel, António O.S.S.
author2_role author
author
author
dc.contributor.none.fl_str_mv Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Ferreira, Francisca T.S.M.
Mesquita, Letícia S.
Mesquita, Raquel B.R.
Rangel, António O.S.S.
dc.subject.por.fl_str_mv Phosphate
Flow analysis
AG1-X8 anionic exchange resin
Molybdenum blue reaction
Groundwater contamination
topic Phosphate
Flow analysis
AG1-X8 anionic exchange resin
Molybdenum blue reaction
Groundwater contamination
description Phosphate is a well-known contaminant and its content is an indicator of water quality, so it is important to have an efficient monitoring of the soil leaching process. In this work, an automatic, low cost flow analysis method, capable of real-time monitoring of the soil leaching processes using spectrophotometric detection, based on the molybdenum blue reaction, was developed. The developed methodology for phosphate determination was based on the molybdenum blue reaction and includes an on-line solid phase extraction (SPE) step, involving an AG1-X8 anionic exchange sorbent. The described SI method enabled phosphate determination within a wide range, 1–80 µM, with a detection limit of 0.52 µM. It was successfully applied to leachates from laboratory scale soil columns (LSSC) and one sample analysis was carried out in triplicate, in less than 10 minutes.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01T00:00:00Z
2021-01-08T16:11:31Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/31611
url http://hdl.handle.net/10400.14/31611
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Ferreira, F. T.S.M., Mesquita, L.S., Mesquita, R.B.R., Rangel, A.O.S.S. (2020). Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates. Talanta Open, 2:100015
2666-8319
10.1016/j.talo.2020.100015
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131970047836160