Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10773/36951 |
Resumo: | People spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping. |
id |
RCAP_e7343e131eedc0f0111b51f722c45481 |
---|---|
oai_identifier_str |
oai:ria.ua.pt:10773/36951 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary studyIndoor air qualitySleepSmokingExposureUltrafine particlesPeople spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping.Elsevier2023-04-12T14:42:07Z2019-06-01T00:00:00Z2019-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/36951eng0269-749110.1016/j.envpol.2019.03.021Canha, NunoLage, JoanaCoutinho, Joana TeixeiraAlves, CéliaAlmeida, Susana Martainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-22T12:11:17Zoai:ria.ua.pt:10773/36951Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:07:38.653826Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
title |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
spellingShingle |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study Canha, Nuno Indoor air quality Sleep Smoking Exposure Ultrafine particles |
title_short |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
title_full |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
title_fullStr |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
title_full_unstemmed |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
title_sort |
Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study |
author |
Canha, Nuno |
author_facet |
Canha, Nuno Lage, Joana Coutinho, Joana Teixeira Alves, Célia Almeida, Susana Marta |
author_role |
author |
author2 |
Lage, Joana Coutinho, Joana Teixeira Alves, Célia Almeida, Susana Marta |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Canha, Nuno Lage, Joana Coutinho, Joana Teixeira Alves, Célia Almeida, Susana Marta |
dc.subject.por.fl_str_mv |
Indoor air quality Sleep Smoking Exposure Ultrafine particles |
topic |
Indoor air quality Sleep Smoking Exposure Ultrafine particles |
description |
People spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-06-01T00:00:00Z 2019-06 2023-04-12T14:42:07Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10773/36951 |
url |
http://hdl.handle.net/10773/36951 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0269-7491 10.1016/j.envpol.2019.03.021 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137731123609600 |