Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study

Detalhes bibliográficos
Autor(a) principal: Canha, Nuno
Data de Publicação: 2019
Outros Autores: Lage, Joana, Coutinho, Joana Teixeira, Alves, Célia, Almeida, Susana Marta
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10773/36951
Resumo: People spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping.
id RCAP_e7343e131eedc0f0111b51f722c45481
oai_identifier_str oai:ria.ua.pt:10773/36951
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary studyIndoor air qualitySleepSmokingExposureUltrafine particlesPeople spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping.Elsevier2023-04-12T14:42:07Z2019-06-01T00:00:00Z2019-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/36951eng0269-749110.1016/j.envpol.2019.03.021Canha, NunoLage, JoanaCoutinho, Joana TeixeiraAlves, CéliaAlmeida, Susana Martainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-22T12:11:17Zoai:ria.ua.pt:10773/36951Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:07:38.653826Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
title Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
spellingShingle Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
Canha, Nuno
Indoor air quality
Sleep
Smoking
Exposure
Ultrafine particles
title_short Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
title_full Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
title_fullStr Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
title_full_unstemmed Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
title_sort Comparison of indoor air quality during sleep in smokers and non-smokers' bedrooms: a preliminary study
author Canha, Nuno
author_facet Canha, Nuno
Lage, Joana
Coutinho, Joana Teixeira
Alves, Célia
Almeida, Susana Marta
author_role author
author2 Lage, Joana
Coutinho, Joana Teixeira
Alves, Célia
Almeida, Susana Marta
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Canha, Nuno
Lage, Joana
Coutinho, Joana Teixeira
Alves, Célia
Almeida, Susana Marta
dc.subject.por.fl_str_mv Indoor air quality
Sleep
Smoking
Exposure
Ultrafine particles
topic Indoor air quality
Sleep
Smoking
Exposure
Ultrafine particles
description People spend one third of their life sleeping, but the bedroom, as a specific micro-environment, is often neglected when assessing human exposure to air pollutants. However, exposure during sleep may be significant in the long-term to the integrated individual exposure. This study aimed to assess the exposure during sleep, focusing on a multi-pollutant approach (comfort parameters, carbon dioxide - CO2, carbon monoxide - CO, formaldehyde (CH2O), total volatile organic compounds (VOCs), particulate matter - PM2.5 and PM10 - and ultrafine particles, particle number concentrations - PNC - and lung deposited surface area - LDSA). For that, the air quality during sleep (in real conditions) was monitored using real-time devices in 12 bedrooms of urban (Lisbon and Vila Franca de Xira) and rural (Ponte de Sor) areas of Portugal for one night. Volunteers were smokers and non-smokers. Considering the Portuguese legislation for indoor air quality (IAQ), 67% of the bedrooms registered CO2 levels above the limit value, while CH2O, VOC, PM10 and PM2.5 thresholds were exceeded in 30, 100, 36, and 45% of cases, respectively. Regarding ultrafine parameters, LDSA and PNC ranged from 7.3 to 95.2 μm2/cm3 and from 0.6 to 4.8 × 103/cm3, respectively. Even with no smoking indoors, smokers' bedrooms were found to have significant higher levels of CO, CH2O, PM2.5, PM10 and LDSA than non-smokers' bedrooms, showing the effect of thirdhand smoke, exhalation of pollutants after smoking and infiltration on the degradation of the air quality in the bedroom. A recent new model of real-time monitor was also used for a wide set of IAQ parameters. Its performance to measure PM2.5 and CO2 was assessed, showing its applicability in real conditions. Although often neglected, these micro-environments should be considered in the integrated individual exposure to air pollutants and further studied. MAIN FINDINGS OF THE WORK: Several pollutants (CO2, PM, VOCs and CH2O) exceeded the guidelines during sleep; smokers are exposed to higher levels of CO, CH2O, PM, and LDSA than non-smokers while sleeping.
publishDate 2019
dc.date.none.fl_str_mv 2019-06-01T00:00:00Z
2019-06
2023-04-12T14:42:07Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/36951
url http://hdl.handle.net/10773/36951
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0269-7491
10.1016/j.envpol.2019.03.021
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137731123609600