Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/26269 |
Resumo: | The study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforced |
id |
RCAP_e792f6f7df973e4d52488206da49cb8c |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/26269 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out testsBond behaviourDouble-Shear pull-out testFibre reinforced polymer (FRP)Local bondslip lawNear Surface Mounted (NSM)Science & TechnologyThe study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforcedFundação para a Ciência e a Tecnologia (FCT)Wiley-BlackwellUniversidade do MinhoCosta, InêsBarros, Joaquim A. O.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/26269eng1475-130510.1111/str.12038info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:09:45Zoai:repositorium.sdum.uminho.pt:1822/26269Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:01:14.979624Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
title |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
spellingShingle |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests Costa, Inês Bond behaviour Double-Shear pull-out test Fibre reinforced polymer (FRP) Local bondslip law Near Surface Mounted (NSM) Science & Technology |
title_short |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
title_full |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
title_fullStr |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
title_full_unstemmed |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
title_sort |
Critical analysis of fibre-reinforced polymer near-surface mounted double-shear pull-out tests |
author |
Costa, Inês |
author_facet |
Costa, Inês Barros, Joaquim A. O. |
author_role |
author |
author2 |
Barros, Joaquim A. O. |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Costa, Inês Barros, Joaquim A. O. |
dc.subject.por.fl_str_mv |
Bond behaviour Double-Shear pull-out test Fibre reinforced polymer (FRP) Local bondslip law Near Surface Mounted (NSM) Science & Technology |
topic |
Bond behaviour Double-Shear pull-out test Fibre reinforced polymer (FRP) Local bondslip law Near Surface Mounted (NSM) Science & Technology |
description |
The study of the bond behaviour between fibre reinforced polymer (FRP) systems and concrete is an issue that nowadays attracts many researchers. The scientific community dedicated to the research of FRP reinforcement has been conducting numerous experimental programs aiming to assess the local bond-slip law of the FRP-adhesive-concrete connection. This paper reports the relevant results obtained by the Structural Composite Research Group of Minho University in the scope of an international Round Robin Test. The suitability of the recommended test setup to derive a local bond constitutive law for modelling the bond behaviour of Near Surface Mounted reinforcement systems is discussed based on a deep interpretation of the results. Keywords: Bond behaviour; Double-Shear pull-out test; Fibre reinforced |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/26269 |
url |
http://hdl.handle.net/1822/26269 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1475-1305 10.1111/str.12038 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Wiley-Blackwell |
publisher.none.fl_str_mv |
Wiley-Blackwell |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132410589216768 |