UNISOL: solar combistore evaluation and optimization
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.9/2418 |
Resumo: | In the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively. |
id |
RCAP_e9de32c7c6742c48bd7bceaf8aadf8f9 |
---|---|
oai_identifier_str |
oai:repositorio.lneg.pt:10400.9/2418 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
UNISOL: solar combistore evaluation and optimizationCombistoreOptimizationDomestic Hot WaterSpace HeatingIn the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively.ElsevierRepositório do LNEGAmorim, RicardoFacão, JorgeRodrigues, João Carlos TeixeiraCarvalho, Maria João2014-04-16T11:19:25Z2014-01-01T00:00:00Z2014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.9/2418engAmorim, R.; Facão, J.; Rodrigues, J.C.; Carvalho, M.J. UNISOL: solar combistore evaluation and optimization. In: Energy Procedia, 2014, Vol. 48, p. 264-2721876-6102info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-06T12:27:25Zoai:repositorio.lneg.pt:10400.9/2418Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:35:18.895492Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
UNISOL: solar combistore evaluation and optimization |
title |
UNISOL: solar combistore evaluation and optimization |
spellingShingle |
UNISOL: solar combistore evaluation and optimization Amorim, Ricardo Combistore Optimization Domestic Hot Water Space Heating |
title_short |
UNISOL: solar combistore evaluation and optimization |
title_full |
UNISOL: solar combistore evaluation and optimization |
title_fullStr |
UNISOL: solar combistore evaluation and optimization |
title_full_unstemmed |
UNISOL: solar combistore evaluation and optimization |
title_sort |
UNISOL: solar combistore evaluation and optimization |
author |
Amorim, Ricardo |
author_facet |
Amorim, Ricardo Facão, Jorge Rodrigues, João Carlos Teixeira Carvalho, Maria João |
author_role |
author |
author2 |
Facão, Jorge Rodrigues, João Carlos Teixeira Carvalho, Maria João |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Repositório do LNEG |
dc.contributor.author.fl_str_mv |
Amorim, Ricardo Facão, Jorge Rodrigues, João Carlos Teixeira Carvalho, Maria João |
dc.subject.por.fl_str_mv |
Combistore Optimization Domestic Hot Water Space Heating |
topic |
Combistore Optimization Domestic Hot Water Space Heating |
description |
In the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-04-16T11:19:25Z 2014-01-01T00:00:00Z 2014-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.9/2418 |
url |
http://hdl.handle.net/10400.9/2418 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Amorim, R.; Facão, J.; Rodrigues, J.C.; Carvalho, M.J. UNISOL: solar combistore evaluation and optimization. In: Energy Procedia, 2014, Vol. 48, p. 264-272 1876-6102 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130218713055232 |