UNISOL: solar combistore evaluation and optimization

Detalhes bibliográficos
Autor(a) principal: Amorim, Ricardo
Data de Publicação: 2014
Outros Autores: Facão, Jorge, Rodrigues, João Carlos Teixeira, Carvalho, Maria João
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.9/2418
Resumo: In the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively.
id RCAP_e9de32c7c6742c48bd7bceaf8aadf8f9
oai_identifier_str oai:repositorio.lneg.pt:10400.9/2418
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling UNISOL: solar combistore evaluation and optimizationCombistoreOptimizationDomestic Hot WaterSpace HeatingIn the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively.ElsevierRepositório do LNEGAmorim, RicardoFacão, JorgeRodrigues, João Carlos TeixeiraCarvalho, Maria João2014-04-16T11:19:25Z2014-01-01T00:00:00Z2014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.9/2418engAmorim, R.; Facão, J.; Rodrigues, J.C.; Carvalho, M.J. UNISOL: solar combistore evaluation and optimization. In: Energy Procedia, 2014, Vol. 48, p. 264-2721876-6102info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-06T12:27:25Zoai:repositorio.lneg.pt:10400.9/2418Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:35:18.895492Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv UNISOL: solar combistore evaluation and optimization
title UNISOL: solar combistore evaluation and optimization
spellingShingle UNISOL: solar combistore evaluation and optimization
Amorim, Ricardo
Combistore
Optimization
Domestic Hot Water
Space Heating
title_short UNISOL: solar combistore evaluation and optimization
title_full UNISOL: solar combistore evaluation and optimization
title_fullStr UNISOL: solar combistore evaluation and optimization
title_full_unstemmed UNISOL: solar combistore evaluation and optimization
title_sort UNISOL: solar combistore evaluation and optimization
author Amorim, Ricardo
author_facet Amorim, Ricardo
Facão, Jorge
Rodrigues, João Carlos Teixeira
Carvalho, Maria João
author_role author
author2 Facão, Jorge
Rodrigues, João Carlos Teixeira
Carvalho, Maria João
author2_role author
author
author
dc.contributor.none.fl_str_mv Repositório do LNEG
dc.contributor.author.fl_str_mv Amorim, Ricardo
Facão, Jorge
Rodrigues, João Carlos Teixeira
Carvalho, Maria João
dc.subject.por.fl_str_mv Combistore
Optimization
Domestic Hot Water
Space Heating
topic Combistore
Optimization
Domestic Hot Water
Space Heating
description In the frame of UNISOL project, a test bench was installed to perform tests of a combistore which includes a two-way heat exchanger already submitted to a national patent application. The present work describes the main characteristics of the test bench installed and the tests performed with the objective of optimization of the configuration of the inner storage tank of the combistore (two way heat exchanger), used for DHW pre-heating or as back-up of the space heating. Tests according to EN 12977-3:2012 were performed in order to evaluate distinct configurations of the inner storage tank. Tests according to EN 12977-4:2012 were also performed for characterization of the complete combistore. Long-term performances of solar thermal systems using these combistore are presented. Long-term performance prediction based on testing results according to EN 12977-3:2012, showed how an increased active volume of the heat exchanger enhances the energy available for space heating, although it may decrease solar collector thermal performance and increase the energy losses of the combistore. Long-term performance prediction based on testing results according to EN 12977-4:2012, considering a lower heat loss coefficient since a better insulation of the combistore is expected in future prototypes, showed fsav values for Davos and Wurzburg of 39.3% and 25.3%, respectively.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-16T11:19:25Z
2014-01-01T00:00:00Z
2014-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.9/2418
url http://hdl.handle.net/10400.9/2418
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Amorim, R.; Facão, J.; Rodrigues, J.C.; Carvalho, M.J. UNISOL: solar combistore evaluation and optimization. In: Energy Procedia, 2014, Vol. 48, p. 264-272
1876-6102
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130218713055232