Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations

Detalhes bibliográficos
Autor(a) principal: Mendes, M
Data de Publicação: 2015
Outros Autores: Costa, F, Figueira, C, Madeira, P, Teles, P, Vaz, P
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.17/3011
Resumo: This work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).
id RCAP_eb42226ecb95cd45ab4cbb857dd83819
oai_identifier_str oai:repositorio.chlc.min-saude.pt:10400.17/3011
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX SimulationsAlgorithmsBreastComputer SimulationComputersEquipment DesignFemaleHumansLens, CrystallineMonte Carlo MethodPhantoms, ImagingProtective DevicesRadiation DosageRadiation ProtectionReproducibility of ResultsThyroid GlandTomography Scanners, X-Ray ComputedTomography, X-Ray ComputedBismuthHSJ IMAThis work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).Oxford University PressRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEMendes, MCosta, FFigueira, CMadeira, PTeles, PVaz, P2018-08-06T15:04:40Z2015-072015-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/3011engRadiat Prot Dosimetry. 2015 Jul;165(1-4):175-81.10.1093/rpd/ncv059info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:40:48Zoai:repositorio.chlc.min-saude.pt:10400.17/3011Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:20:19.369175Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
title Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
spellingShingle Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
Mendes, M
Algorithms
Breast
Computer Simulation
Computers
Equipment Design
Female
Humans
Lens, Crystalline
Monte Carlo Method
Phantoms, Imaging
Protective Devices
Radiation Dosage
Radiation Protection
Reproducibility of Results
Thyroid Gland
Tomography Scanners, X-Ray Computed
Tomography, X-Ray Computed
Bismuth
HSJ IMA
title_short Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
title_full Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
title_fullStr Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
title_full_unstemmed Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
title_sort Assessment of Patient Dose Reduction by Bismuth Shielding in CT Using Measurements, GEANT4 and MCNPX Simulations
author Mendes, M
author_facet Mendes, M
Costa, F
Figueira, C
Madeira, P
Teles, P
Vaz, P
author_role author
author2 Costa, F
Figueira, C
Madeira, P
Teles, P
Vaz, P
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE
dc.contributor.author.fl_str_mv Mendes, M
Costa, F
Figueira, C
Madeira, P
Teles, P
Vaz, P
dc.subject.por.fl_str_mv Algorithms
Breast
Computer Simulation
Computers
Equipment Design
Female
Humans
Lens, Crystalline
Monte Carlo Method
Phantoms, Imaging
Protective Devices
Radiation Dosage
Radiation Protection
Reproducibility of Results
Thyroid Gland
Tomography Scanners, X-Ray Computed
Tomography, X-Ray Computed
Bismuth
HSJ IMA
topic Algorithms
Breast
Computer Simulation
Computers
Equipment Design
Female
Humans
Lens, Crystalline
Monte Carlo Method
Phantoms, Imaging
Protective Devices
Radiation Dosage
Radiation Protection
Reproducibility of Results
Thyroid Gland
Tomography Scanners, X-Ray Computed
Tomography, X-Ray Computed
Bismuth
HSJ IMA
description This work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).
publishDate 2015
dc.date.none.fl_str_mv 2015-07
2015-07-01T00:00:00Z
2018-08-06T15:04:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/3011
url http://hdl.handle.net/10400.17/3011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Radiat Prot Dosimetry. 2015 Jul;165(1-4):175-81.
10.1093/rpd/ncv059
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Oxford University Press
publisher.none.fl_str_mv Oxford University Press
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131299728850944