Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters

Detalhes bibliográficos
Autor(a) principal: Campinas, M.
Data de Publicação: 2010
Outros Autores: Rosa, M. J.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://repositorio.lnec.pt:8080/jspui/handle/123456789/1000265
Resumo: PAC/UF was investigated for removing M. aeruginosa cells and microcystins from natural waters and its performance was compared with the conventional clarifi cation with PAC addition (PAC+C/F/S). Ozonated and clarified waters from Tavira’s Water Treatment Plant were used. Both processes achieved an absolute removal of chlorophyll-a, but greater turbidity and microcystins (intra and extracellular) removals were reached by PAC/UF. With PAC/UF, 10 mg/L PAC resulted in a cycle-averaged concentration of microcystins in the permeate (0.72 μg/L MC-LReq) below the WHO guideline value, while the water quality obtained with 15 mg/L PAC+C/F/S was far beyond that guideline value. However, the occurrence of cell lysis during UF (with subsequent release of microcystins and UV254nm absorbing substances) and the preferential removal of high molar mass compounds by coagulation yielded better UV254nm removals by PAC+C/F/S. Natural organic matter showed a small impact onto microcystins removal, with greater effect of some algogenic compounds, but especially of high concentrations of humic and tannic-like compounds.
id RCAP_f1e1755bb70f5de0c20e9024c50d6cf0
oai_identifier_str oai:localhost:123456789/1000265
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural watersPac/ufClarificationMicrocystinsAomNomPAC/UF was investigated for removing M. aeruginosa cells and microcystins from natural waters and its performance was compared with the conventional clarifi cation with PAC addition (PAC+C/F/S). Ozonated and clarified waters from Tavira’s Water Treatment Plant were used. Both processes achieved an absolute removal of chlorophyll-a, but greater turbidity and microcystins (intra and extracellular) removals were reached by PAC/UF. With PAC/UF, 10 mg/L PAC resulted in a cycle-averaged concentration of microcystins in the permeate (0.72 μg/L MC-LReq) below the WHO guideline value, while the water quality obtained with 15 mg/L PAC+C/F/S was far beyond that guideline value. However, the occurrence of cell lysis during UF (with subsequent release of microcystins and UV254nm absorbing substances) and the preferential removal of high molar mass compounds by coagulation yielded better UV254nm removals by PAC+C/F/S. Natural organic matter showed a small impact onto microcystins removal, with greater effect of some algogenic compounds, but especially of high concentrations of humic and tannic-like compounds.Desalination Publications2010-06-18T14:44:36Z2014-10-20T12:57:28Z2017-04-13T12:10:20Z2010-04-01T00:00:00Z2010-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://repositorio.lnec.pt:8080/jspui/handle/123456789/1000265eng1944-3994Campinas, M.Rosa, M. J.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-13T03:07:00Zoai:localhost:123456789/1000265Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:40:11.425526Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
title Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
spellingShingle Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
Campinas, M.
Pac/uf
Clarification
Microcystins
Aom
Nom
title_short Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
title_full Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
title_fullStr Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
title_full_unstemmed Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
title_sort Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters
author Campinas, M.
author_facet Campinas, M.
Rosa, M. J.
author_role author
author2 Rosa, M. J.
author2_role author
dc.contributor.author.fl_str_mv Campinas, M.
Rosa, M. J.
dc.subject.por.fl_str_mv Pac/uf
Clarification
Microcystins
Aom
Nom
topic Pac/uf
Clarification
Microcystins
Aom
Nom
description PAC/UF was investigated for removing M. aeruginosa cells and microcystins from natural waters and its performance was compared with the conventional clarifi cation with PAC addition (PAC+C/F/S). Ozonated and clarified waters from Tavira’s Water Treatment Plant were used. Both processes achieved an absolute removal of chlorophyll-a, but greater turbidity and microcystins (intra and extracellular) removals were reached by PAC/UF. With PAC/UF, 10 mg/L PAC resulted in a cycle-averaged concentration of microcystins in the permeate (0.72 μg/L MC-LReq) below the WHO guideline value, while the water quality obtained with 15 mg/L PAC+C/F/S was far beyond that guideline value. However, the occurrence of cell lysis during UF (with subsequent release of microcystins and UV254nm absorbing substances) and the preferential removal of high molar mass compounds by coagulation yielded better UV254nm removals by PAC+C/F/S. Natural organic matter showed a small impact onto microcystins removal, with greater effect of some algogenic compounds, but especially of high concentrations of humic and tannic-like compounds.
publishDate 2010
dc.date.none.fl_str_mv 2010-06-18T14:44:36Z
2010-04-01T00:00:00Z
2010-04
2014-10-20T12:57:28Z
2017-04-13T12:10:20Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.lnec.pt:8080/jspui/handle/123456789/1000265
url http://repositorio.lnec.pt:8080/jspui/handle/123456789/1000265
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1944-3994
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Desalination Publications
publisher.none.fl_str_mv Desalination Publications
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136890924826624