Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage

Detalhes bibliográficos
Autor(a) principal: Pedro Fonseca Mota
Data de Publicação: 2010
Outros Autores: José A. Machado da Silva, Ricardo A. Veiga
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://repositorio-aberto.up.pt/handle/10216/57159
Resumo: The estimation of 1 dB compression and third-order intercept points can be obtained after the cross-correlation between dynamic current and output voltage of radio frequency power amplifiers. This estimation is performed using actual power measures and not power inferred from voltage measurements. The underlining theory and a correlator that allows implementing this measurement on-chip are presented. The trade-off between measuring voltage and the actual power is also discussed and it is shown that different information concerning the output load is obtained when observing the PA's output voltage and power. Simulation results, obtained with the model of a prototype demonstration chip, show that good accuracy can be obtained with relatively simple measurement conditions. These results include the analysis of optimum stimuli amplitudes and the effect of noise in estimation accuracy.
id RCAP_f2ffdcc97bdde3dfc3b38e54445c1b05
oai_identifier_str oai:repositorio-aberto.up.pt:10216/57159
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output VoltageMicro-sistemas, Engenharia de telecomunicações, Engenharia electrónica, Engenharia electrotécnica, electrónica e informáticaMicrosystems, Telecommunications engineering, Electronic engineering, Electrical engineering, Electronic engineering, Information engineeringThe estimation of 1 dB compression and third-order intercept points can be obtained after the cross-correlation between dynamic current and output voltage of radio frequency power amplifiers. This estimation is performed using actual power measures and not power inferred from voltage measurements. The underlining theory and a correlator that allows implementing this measurement on-chip are presented. The trade-off between measuring voltage and the actual power is also discussed and it is shown that different information concerning the output load is obtained when observing the PA's output voltage and power. Simulation results, obtained with the model of a prototype demonstration chip, show that good accuracy can be obtained with relatively simple measurement conditions. These results include the analysis of optimum stimuli amplitudes and the effect of noise in estimation accuracy.20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://repositorio-aberto.up.pt/handle/10216/57159engDOI 10.1007/s10836-009-5128-0Pedro Fonseca MotaJosé A. Machado da SilvaRicardo A. Veigainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T12:57:20Zoai:repositorio-aberto.up.pt:10216/57159Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:30:22.803302Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
title Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
spellingShingle Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
Pedro Fonseca Mota
Micro-sistemas, Engenharia de telecomunicações, Engenharia electrónica, Engenharia electrotécnica, electrónica e informática
Microsystems, Telecommunications engineering, Electronic engineering, Electrical engineering, Electronic engineering, Information engineering
title_short Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
title_full Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
title_fullStr Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
title_full_unstemmed Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
title_sort Estimation of RF PA Non-Linearities After Cross-Correlating Current and Output Voltage
author Pedro Fonseca Mota
author_facet Pedro Fonseca Mota
José A. Machado da Silva
Ricardo A. Veiga
author_role author
author2 José A. Machado da Silva
Ricardo A. Veiga
author2_role author
author
dc.contributor.author.fl_str_mv Pedro Fonseca Mota
José A. Machado da Silva
Ricardo A. Veiga
dc.subject.por.fl_str_mv Micro-sistemas, Engenharia de telecomunicações, Engenharia electrónica, Engenharia electrotécnica, electrónica e informática
Microsystems, Telecommunications engineering, Electronic engineering, Electrical engineering, Electronic engineering, Information engineering
topic Micro-sistemas, Engenharia de telecomunicações, Engenharia electrónica, Engenharia electrotécnica, electrónica e informática
Microsystems, Telecommunications engineering, Electronic engineering, Electrical engineering, Electronic engineering, Information engineering
description The estimation of 1 dB compression and third-order intercept points can be obtained after the cross-correlation between dynamic current and output voltage of radio frequency power amplifiers. This estimation is performed using actual power measures and not power inferred from voltage measurements. The underlining theory and a correlator that allows implementing this measurement on-chip are presented. The trade-off between measuring voltage and the actual power is also discussed and it is shown that different information concerning the output load is obtained when observing the PA's output voltage and power. Simulation results, obtained with the model of a prototype demonstration chip, show that good accuracy can be obtained with relatively simple measurement conditions. These results include the analysis of optimum stimuli amplitudes and the effect of noise in estimation accuracy.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio-aberto.up.pt/handle/10216/57159
url https://repositorio-aberto.up.pt/handle/10216/57159
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv DOI 10.1007/s10836-009-5128-0
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799135611566686209