Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.22/14924 |
Resumo: | Background: An increasingly aging society and consequently rising number of patients with poststroke-related neurological dysfunctions are forcing the rehabilitation field to adapt to ever-growing demands. Although clinical reasoning within rehabilitation is dependent on patient movement performance analysis, current strategies for monitoring rehabilitation progress are based on subjective time-consuming assessment scales, not often applied. Therefore, a need exists for efficient nonsubjective monitoring methods. Wearable monitoring devices are rapidly becoming a recognized option in rehabilitation for quantitative measures. Developments in sensors, embedded technology, and smart textile are driving rehabilitation to adopt an objective, seamless, efficient, and cost-effective delivery system. This study aims to assist physiotherapists’ clinical reasoning process through the incorporation of accelerometers as part of an electronic data acquisition system. Methods: A simple, low-cost, wearable device for poststroke rehabilitation progress monitoring was developed based on commercially available inertial sensors. Accelerometry data acquisition was performed for 4 first-time poststroke patients during a reach-press-return task. Results: Preliminary studies revealed acceleration profiles of stroke patients through which it is possible to quantitatively assess the functional movement, identify compensatory strategies, and help define proper movement. Conclusion: An inertial data acquisition system was designed and developed as a low-cost option for monitoring rehabilitation. The device seeks to ease the data-gathering process by physiotherapists to complement current practices with accelerometry profiles and aid the development of quantifiable methodologies and protocols. |
id |
RCAP_f3a02d73b02d40ef8831d12354afdcec |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/14924 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task AssessmentAlgorithmsNervous System DiseasesStrokeTelemetryClothingElectronic Data ProcessingMonitoring, AmbulatoryStroke RehabilitationBackground: An increasingly aging society and consequently rising number of patients with poststroke-related neurological dysfunctions are forcing the rehabilitation field to adapt to ever-growing demands. Although clinical reasoning within rehabilitation is dependent on patient movement performance analysis, current strategies for monitoring rehabilitation progress are based on subjective time-consuming assessment scales, not often applied. Therefore, a need exists for efficient nonsubjective monitoring methods. Wearable monitoring devices are rapidly becoming a recognized option in rehabilitation for quantitative measures. Developments in sensors, embedded technology, and smart textile are driving rehabilitation to adopt an objective, seamless, efficient, and cost-effective delivery system. This study aims to assist physiotherapists’ clinical reasoning process through the incorporation of accelerometers as part of an electronic data acquisition system. Methods: A simple, low-cost, wearable device for poststroke rehabilitation progress monitoring was developed based on commercially available inertial sensors. Accelerometry data acquisition was performed for 4 first-time poststroke patients during a reach-press-return task. Results: Preliminary studies revealed acceleration profiles of stroke patients through which it is possible to quantitatively assess the functional movement, identify compensatory strategies, and help define proper movement. Conclusion: An inertial data acquisition system was designed and developed as a low-cost option for monitoring rehabilitation. The device seeks to ease the data-gathering process by physiotherapists to complement current practices with accelerometry profiles and aid the development of quantifiable methodologies and protocols.Taylor & FrancisRepositório Científico do Instituto Politécnico do PortoSalazar, Antonio J.Silva, Ana S.Silva, CláudiaBorges, Carla M.Correia, Miguel V.Santos, RubimVilas-Boas, Joao P.2019-11-22T13:27:30Z20142014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/14924eng10.1310/tsr2101-12info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:58:34Zoai:recipp.ipp.pt:10400.22/14924Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:34:43.743346Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
title |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
spellingShingle |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment Salazar, Antonio J. Algorithms Nervous System Diseases Stroke Telemetry Clothing Electronic Data Processing Monitoring, Ambulatory Stroke Rehabilitation |
title_short |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
title_full |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
title_fullStr |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
title_full_unstemmed |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
title_sort |
Low-Cost Wearable Data Acquisition for Stroke Rehabilitation: A Proof-of-Concept Study on Accelerometry for Functional Task Assessment |
author |
Salazar, Antonio J. |
author_facet |
Salazar, Antonio J. Silva, Ana S. Silva, Cláudia Borges, Carla M. Correia, Miguel V. Santos, Rubim Vilas-Boas, Joao P. |
author_role |
author |
author2 |
Silva, Ana S. Silva, Cláudia Borges, Carla M. Correia, Miguel V. Santos, Rubim Vilas-Boas, Joao P. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico do Porto |
dc.contributor.author.fl_str_mv |
Salazar, Antonio J. Silva, Ana S. Silva, Cláudia Borges, Carla M. Correia, Miguel V. Santos, Rubim Vilas-Boas, Joao P. |
dc.subject.por.fl_str_mv |
Algorithms Nervous System Diseases Stroke Telemetry Clothing Electronic Data Processing Monitoring, Ambulatory Stroke Rehabilitation |
topic |
Algorithms Nervous System Diseases Stroke Telemetry Clothing Electronic Data Processing Monitoring, Ambulatory Stroke Rehabilitation |
description |
Background: An increasingly aging society and consequently rising number of patients with poststroke-related neurological dysfunctions are forcing the rehabilitation field to adapt to ever-growing demands. Although clinical reasoning within rehabilitation is dependent on patient movement performance analysis, current strategies for monitoring rehabilitation progress are based on subjective time-consuming assessment scales, not often applied. Therefore, a need exists for efficient nonsubjective monitoring methods. Wearable monitoring devices are rapidly becoming a recognized option in rehabilitation for quantitative measures. Developments in sensors, embedded technology, and smart textile are driving rehabilitation to adopt an objective, seamless, efficient, and cost-effective delivery system. This study aims to assist physiotherapists’ clinical reasoning process through the incorporation of accelerometers as part of an electronic data acquisition system. Methods: A simple, low-cost, wearable device for poststroke rehabilitation progress monitoring was developed based on commercially available inertial sensors. Accelerometry data acquisition was performed for 4 first-time poststroke patients during a reach-press-return task. Results: Preliminary studies revealed acceleration profiles of stroke patients through which it is possible to quantitatively assess the functional movement, identify compensatory strategies, and help define proper movement. Conclusion: An inertial data acquisition system was designed and developed as a low-cost option for monitoring rehabilitation. The device seeks to ease the data-gathering process by physiotherapists to complement current practices with accelerometry profiles and aid the development of quantifiable methodologies and protocols. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014 2014-01-01T00:00:00Z 2019-11-22T13:27:30Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/14924 |
url |
http://hdl.handle.net/10400.22/14924 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1310/tsr2101-12 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Taylor & Francis |
publisher.none.fl_str_mv |
Taylor & Francis |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131438866497536 |