The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling
Autor(a) principal: | |
---|---|
Data de Publicação: | 2002 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/4014 |
Resumo: | We present the results of a study of an argon gas proportional scintillation counter instrumented with a CsI-coated microstrip plate placed in the argon envelope. Although the measured light amplification gain and the photoelectron collection efficiency are 70% and 30-40% higher than those obtained in a similar xenon detector, the charge gain achieved in argon for the avalanches produced by the photoelectrons at the microstrip anodes is a factor of ten lower than in xenon. In both cases, these gains are limited by optical positive feedback. The energy resolution achieved for 5.9 keV X-rays was 14.8% compared to 12% in xenon. |
id |
RCAP_f5a78549eaf9740d565acf29383094fe |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4014 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon fillingGas scintillation countersCsI photocathodesWe present the results of a study of an argon gas proportional scintillation counter instrumented with a CsI-coated microstrip plate placed in the argon envelope. Although the measured light amplification gain and the photoelectron collection efficiency are 70% and 30-40% higher than those obtained in a similar xenon detector, the charge gain achieved in argon for the avalanches produced by the photoelectrons at the microstrip anodes is a factor of ten lower than in xenon. In both cases, these gains are limited by optical positive feedback. The energy resolution achieved for 5.9 keV X-rays was 14.8% compared to 12% in xenon.http://www.sciencedirect.com/science/article/B6TJM-45SHB0C-3/1/2d0511e0866173bb27b1a2d57ceb55cd2002info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4014http://hdl.handle.net/10316/4014engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 490:1-2 (2002) 169-176Monteiro, C. M. B.Veloso, J. F. C. A.Freitas, D. S. A. P.Santos, J. M. F. dosConde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-10-22T09:44:17Zoai:estudogeral.uc.pt:10316/4014Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:57:13.393642Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
title |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
spellingShingle |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling Monteiro, C. M. B. Gas scintillation counters CsI photocathodes |
title_short |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
title_full |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
title_fullStr |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
title_full_unstemmed |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
title_sort |
The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling |
author |
Monteiro, C. M. B. |
author_facet |
Monteiro, C. M. B. Veloso, J. F. C. A. Freitas, D. S. A. P. Santos, J. M. F. dos Conde, C. A. N. |
author_role |
author |
author2 |
Veloso, J. F. C. A. Freitas, D. S. A. P. Santos, J. M. F. dos Conde, C. A. N. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Monteiro, C. M. B. Veloso, J. F. C. A. Freitas, D. S. A. P. Santos, J. M. F. dos Conde, C. A. N. |
dc.subject.por.fl_str_mv |
Gas scintillation counters CsI photocathodes |
topic |
Gas scintillation counters CsI photocathodes |
description |
We present the results of a study of an argon gas proportional scintillation counter instrumented with a CsI-coated microstrip plate placed in the argon envelope. Although the measured light amplification gain and the photoelectron collection efficiency are 70% and 30-40% higher than those obtained in a similar xenon detector, the charge gain achieved in argon for the avalanches produced by the photoelectrons at the microstrip anodes is a factor of ten lower than in xenon. In both cases, these gains are limited by optical positive feedback. The energy resolution achieved for 5.9 keV X-rays was 14.8% compared to 12% in xenon. |
publishDate |
2002 |
dc.date.none.fl_str_mv |
2002 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/4014 http://hdl.handle.net/10316/4014 |
url |
http://hdl.handle.net/10316/4014 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 490:1-2 (2002) 169-176 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133860180525056 |