The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

Detalhes bibliográficos
Autor(a) principal: Onofre, A.
Data de Publicação: 2016
Outros Autores: Castro, Nuno Filipe Silva Fernandes, ATLAS Collaboration
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/43761
Resumo: This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Finally, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.
id RCAP_f8323f2f3f678751c8853608c09e54e6
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/43761
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1Detector alignment and calibration methods (lasers, sources, particle-beams)CalorimetersPerformance of High Energy Physics DetectorsDetector alignment and calibration methods (lasers, sources, particle-beams); CalorimetersCiências Naturais::Ciências FísicasScience & TechnologyThis article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Finally, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.IOP PublishingUniversidade do MinhoOnofre, A.Castro, Nuno Filipe Silva FernandesATLAS Collaboration20162016-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/43761engAbdallah, J., Alexa, C., Coutinho, Y. A., Santos, S. P. A. D., Anderson, K. J., Arabidze, G., . . . Van Woerden, M. C. (2016). The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1. [Article]. Journal of Instrumentation, 11(10). doi: 10.1088/1748-0221/11/10/t100051748-02211748-022110.1088/1748-0221/11/10/t10005info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:34:56Zoai:repositorium.sdum.uminho.pt:1822/43761Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:30:42.074157Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
title The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
spellingShingle The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
Onofre, A.
Detector alignment and calibration methods (lasers, sources, particle-beams)
Calorimeters
Performance of High Energy Physics Detectors
Detector alignment and calibration methods (lasers, sources, particle-beams); Calorimeters
Ciências Naturais::Ciências Físicas
Science & Technology
title_short The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
title_full The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
title_fullStr The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
title_full_unstemmed The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
title_sort The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1
author Onofre, A.
author_facet Onofre, A.
Castro, Nuno Filipe Silva Fernandes
ATLAS Collaboration
author_role author
author2 Castro, Nuno Filipe Silva Fernandes
ATLAS Collaboration
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Onofre, A.
Castro, Nuno Filipe Silva Fernandes
ATLAS Collaboration
dc.subject.por.fl_str_mv Detector alignment and calibration methods (lasers, sources, particle-beams)
Calorimeters
Performance of High Energy Physics Detectors
Detector alignment and calibration methods (lasers, sources, particle-beams); Calorimeters
Ciências Naturais::Ciências Físicas
Science & Technology
topic Detector alignment and calibration methods (lasers, sources, particle-beams)
Calorimeters
Performance of High Energy Physics Detectors
Detector alignment and calibration methods (lasers, sources, particle-beams); Calorimeters
Ciências Naturais::Ciências Físicas
Science & Technology
description This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Finally, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.
publishDate 2016
dc.date.none.fl_str_mv 2016
2016-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/43761
url http://hdl.handle.net/1822/43761
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Abdallah, J., Alexa, C., Coutinho, Y. A., Santos, S. P. A. D., Anderson, K. J., Arabidze, G., . . . Van Woerden, M. C. (2016). The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1. [Article]. Journal of Instrumentation, 11(10). doi: 10.1088/1748-0221/11/10/t10005
1748-0221
1748-0221
10.1088/1748-0221/11/10/t10005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv IOP Publishing
publisher.none.fl_str_mv IOP Publishing
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132812121473024