Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines

Detalhes bibliográficos
Autor(a) principal: Lança, Luís
Data de Publicação: 2008
Outros Autores: Silva, Augusto, Alves, Eduardo, Serranheira, Florentino, Correia, Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/992
Resumo: Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.
id RCAP_f90c7fd4d154bd085d9e030b6899644c
oai_identifier_str oai:repositorio.ipl.pt:10400.21/992
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Evaluation of exposure parameters in plain radiography: a comparative study with european guidelinesRadiologiaDosimetriaNíveis de referência de diagnósticoGuidelinesRadiologyDosimetryDiagnostic reference levelsPortugalGrande LisboaTypical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.Oxford University PressRCIPLLança, LuísSilva, AugustoAlves, EduardoSerranheira, FlorentinoCorreia, Manuel2012-01-03T11:59:26Z20082008-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/992engLança L, Silva A, Alves E, Serranheira F, Correia M. Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines. Radiat Prot Dosimetry. 2008;129(1-3):316-20.1742-3406info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:38:27Zoai:repositorio.ipl.pt:10400.21/992Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:11:08.804933Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
title Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
spellingShingle Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
Lança, Luís
Radiologia
Dosimetria
Níveis de referência de diagnóstico
Guidelines
Radiology
Dosimetry
Diagnostic reference levels
Portugal
Grande Lisboa
title_short Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
title_full Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
title_fullStr Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
title_full_unstemmed Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
title_sort Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines
author Lança, Luís
author_facet Lança, Luís
Silva, Augusto
Alves, Eduardo
Serranheira, Florentino
Correia, Manuel
author_role author
author2 Silva, Augusto
Alves, Eduardo
Serranheira, Florentino
Correia, Manuel
author2_role author
author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Lança, Luís
Silva, Augusto
Alves, Eduardo
Serranheira, Florentino
Correia, Manuel
dc.subject.por.fl_str_mv Radiologia
Dosimetria
Níveis de referência de diagnóstico
Guidelines
Radiology
Dosimetry
Diagnostic reference levels
Portugal
Grande Lisboa
topic Radiologia
Dosimetria
Níveis de referência de diagnóstico
Guidelines
Radiology
Dosimetry
Diagnostic reference levels
Portugal
Grande Lisboa
description Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.
publishDate 2008
dc.date.none.fl_str_mv 2008
2008-01-01T00:00:00Z
2012-01-03T11:59:26Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/992
url http://hdl.handle.net/10400.21/992
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Lança L, Silva A, Alves E, Serranheira F, Correia M. Evaluation of exposure parameters in plain radiography: a comparative study with european guidelines. Radiat Prot Dosimetry. 2008;129(1-3):316-20.
1742-3406
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Oxford University Press
publisher.none.fl_str_mv Oxford University Press
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133363211075584