Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.26/26545 |
Resumo: | The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented. |
id |
RCAP_fa52e9a7729c329458f10164f323ceec |
---|---|
oai_identifier_str |
oai:comum.rcaap.pt:10400.26/26545 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter DetectorThe Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.Repositório ComumAkerib, D.S. et al. (80 authors)de Viveiros, L.Lindote, A.Lopes, M.I.Neves, F.Silva, C.Solovov, V.N.2019-02-04T00:17:49Z2015-032019-02-04T00:17:49Z2015-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.26/26545enghttp://dx.doi.org/10.1016/j.astropartphys.2014.07.009info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-16T07:27:21Zoai:comum.rcaap.pt:10400.26/26545Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-16T07:27:21Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
title |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
spellingShingle |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector Akerib, D.S. et al. (80 authors) |
title_short |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
title_full |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
title_fullStr |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
title_full_unstemmed |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
title_sort |
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector |
author |
Akerib, D.S. et al. (80 authors) |
author_facet |
Akerib, D.S. et al. (80 authors) de Viveiros, L. Lindote, A. Lopes, M.I. Neves, F. Silva, C. Solovov, V.N. |
author_role |
author |
author2 |
de Viveiros, L. Lindote, A. Lopes, M.I. Neves, F. Silva, C. Solovov, V.N. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório Comum |
dc.contributor.author.fl_str_mv |
Akerib, D.S. et al. (80 authors) de Viveiros, L. Lindote, A. Lopes, M.I. Neves, F. Silva, C. Solovov, V.N. |
description |
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-03 2015-03-01T00:00:00Z 2019-02-04T00:17:49Z 2019-02-04T00:17:49Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.26/26545 |
url |
http://hdl.handle.net/10400.26/26545 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://dx.doi.org/10.1016/j.astropartphys.2014.07.009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817545416519974912 |