Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool

Detalhes bibliográficos
Autor(a) principal: Seixas, Mafalda
Data de Publicação: 2015
Outros Autores: Melício, Rui, Mendes, Victor
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/5732
Resumo: This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
id RCAP_fbd2fadb39eabc7f3259fe6a4eed542e
oai_identifier_str oai:repositorio.ipl.pt:10400.21/5732
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context toolOffshore wind systemHVDC lightFour-level converterUnbalance capacitor voltageRectifier malfunctionSmart gridSimulationThis paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.Pergamon-Elsevier Science LTDRCIPLSeixas, MafaldaMelício, RuiMendes, Victor2016-02-24T15:45:39Z2015-062015-06-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/5732engSEIXAS, Mafalda; MELÍCIO, Rui; MENDES, Victor Manuel Fernandes - Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool. Energy Conversion and Mangement. ISSN. 0196-8904. Vol. 97 (2015), pp. 140-1530196-890410.1016/j.enconman.2015.03.050metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:49:34Zoai:repositorio.ipl.pt:10400.21/5732Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:14:58.639364Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
spellingShingle Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
Seixas, Mafalda
Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
title_short Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_full Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_fullStr Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_full_unstemmed Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
title_sort Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
author Seixas, Mafalda
author_facet Seixas, Mafalda
Melício, Rui
Mendes, Victor
author_role author
author2 Melício, Rui
Mendes, Victor
author2_role author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Seixas, Mafalda
Melício, Rui
Mendes, Victor
dc.subject.por.fl_str_mv Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
topic Offshore wind system
HVDC light
Four-level converter
Unbalance capacitor voltage
Rectifier malfunction
Smart grid
Simulation
description This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
publishDate 2015
dc.date.none.fl_str_mv 2015-06
2015-06-01T00:00:00Z
2016-02-24T15:45:39Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/5732
url http://hdl.handle.net/10400.21/5732
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv SEIXAS, Mafalda; MELÍCIO, Rui; MENDES, Victor Manuel Fernandes - Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool. Energy Conversion and Mangement. ISSN. 0196-8904. Vol. 97 (2015), pp. 140-153
0196-8904
10.1016/j.enconman.2015.03.050
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pergamon-Elsevier Science LTD
publisher.none.fl_str_mv Pergamon-Elsevier Science LTD
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133407920259072