Assessment of 3D scanners for modeling Pectus Carinatum corrective bar

Detalhes bibliográficos
Autor(a) principal: Moreira, António H. J.
Data de Publicação: 2013
Outros Autores: Fonseca, João Gomes, Rodrigues, Pedro L., Fonseca, Jaime C., Pinho, A.C.M., Correia-Pinto, Jorge, F. Rodrigues, Nuno, Vilaça, João L.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/11110/509
Resumo: Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor
id RCAP_fc219dff66529528825bf666b6319215
oai_identifier_str oai:ciencipca.ipca.pt:11110/509
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Assessment of 3D scanners for modeling Pectus Carinatum corrective bar3D scannerKinectFastSCANPectus CarinatumSurface mesh3D reconstructionPectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor2013-12-19T17:31:05Z2013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/11110/509oai:ciencipca.ipca.pt:11110/509eng9789898565471http://hdl.handle.net/11110/509metadata only accessinfo:eu-repo/semantics/openAccessMoreira, António H. J.Fonseca, João GomesRodrigues, Pedro L.Fonseca, Jaime C.Pinho, A.C.M.Correia-Pinto, JorgeF. Rodrigues, NunoVilaça, João L.reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-05T12:52:05Zoai:ciencipca.ipca.pt:11110/509Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:00:58.277506Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
title Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
spellingShingle Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
Moreira, António H. J.
3D scanner
Kinect
FastSCAN
Pectus Carinatum
Surface mesh
3D reconstruction
title_short Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
title_full Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
title_fullStr Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
title_full_unstemmed Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
title_sort Assessment of 3D scanners for modeling Pectus Carinatum corrective bar
author Moreira, António H. J.
author_facet Moreira, António H. J.
Fonseca, João Gomes
Rodrigues, Pedro L.
Fonseca, Jaime C.
Pinho, A.C.M.
Correia-Pinto, Jorge
F. Rodrigues, Nuno
Vilaça, João L.
author_role author
author2 Fonseca, João Gomes
Rodrigues, Pedro L.
Fonseca, Jaime C.
Pinho, A.C.M.
Correia-Pinto, Jorge
F. Rodrigues, Nuno
Vilaça, João L.
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Moreira, António H. J.
Fonseca, João Gomes
Rodrigues, Pedro L.
Fonseca, Jaime C.
Pinho, A.C.M.
Correia-Pinto, Jorge
F. Rodrigues, Nuno
Vilaça, João L.
dc.subject.por.fl_str_mv 3D scanner
Kinect
FastSCAN
Pectus Carinatum
Surface mesh
3D reconstruction
topic 3D scanner
Kinect
FastSCAN
Pectus Carinatum
Surface mesh
3D reconstruction
description Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor
publishDate 2013
dc.date.none.fl_str_mv 2013-12-19T17:31:05Z
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/11110/509
oai:ciencipca.ipca.pt:11110/509
url http://hdl.handle.net/11110/509
identifier_str_mv oai:ciencipca.ipca.pt:11110/509
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 9789898565471
http://hdl.handle.net/11110/509
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129879880400896