Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation

Detalhes bibliográficos
Autor(a) principal: Carvalheiro, José Pedro Neto
Data de Publicação: 2021
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/98587
Resumo: Dissertação de Mestrado Integrado em Engenharia Electrotécnica e de Computadores apresentada à Faculdade de Ciências e Tecnologia
id RCAP_fc361f62c5816edf1b530071fd60181d
oai_identifier_str oai:estudogeral.uc.pt:10316/98587
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and ValidationDispositivo Vestível para Monitoramento de SpO2 na zona torácica: Projeto, Fabricação e ValidaçãoDispositivos vestíveisEletrónica ConformávelOximetria de PulsoPPGSpO2Wearable devicesConformable ElectronicsPulse OximetryPPGSpO2Dissertação de Mestrado Integrado em Engenharia Electrotécnica e de Computadores apresentada à Faculdade de Ciências e TecnologiaHá um interesse crescente em dispositivos vestíveis de saúde devido à sua aplicação no monitoramento remoto de pacientes. No caso de monitoramento frequente de sinais vitais com dispositivos vestíveis, seria possível definir uma base de dados de saúde individual para que os usuários e profissionais médicos pudessem tomar medidas necessárias, dependendo das anomalias detetadas. Os instrumentos médicos convencionais são volumosos e geralmente feitos de componentes eletrônicos rígidos, não sendo adequados para esse fim. A incompatibilidade mecânica entre a eletrônica rígida tradicional e os tecidos biológicos resulta em sistemas que não se adaptam suficientemente à epiderme humana e geralmente são impraticáveis para monitoramento de longo prazo. Esta tem sido uma das motivações para a eletrônica flexível e elástica, que visa o desenvolvimento de dispositivos eletrônicos de matéria macia que se adaptam à pele humana e podem suportar flexões e esforços mecânicos enquanto mantêm sua funcionalidade e qualidade de sinal. Esta dissertação faz parte de um grande projeto da CMU Portugal (WoW) que visa desenvolver um sistema de vestível que monitoriza simultaneamente frequência cardíaca, temperatura corporal, movimentos corporais, frequência respiratória e saturação de oxigénio (SpO2). A equipa do ISR já implementou todas essas funções num cinto e-¬têxtil vestível e um adesivo, exceto para o SpO2. Ambos os dispositivos concentram os seus sensores na zona do tórax. No entanto, os poucos trabalhos da literatura que estudam a medição de SpO2 na zona do tórax definem a tarefa como desafiadora. No entanto, nenhum desenvolveu um adesivo de matéria mole verdadeiramente adaptável à pele. Portanto, o objetivo principal deste trabalho é projetar e desenvolver um patch de medição de SpO2 de matéria mole, entender se é viável medir SpO2 na zona torácica e se um patch de monitoramento de SpO2 macio e conformável pode resolver esse problema. Além disso, este trabalho aborda alguns dos desafios na fabricação de componentes eletrônicos flexíveis de alta resolução que podem incorporar microcomponentes SMD. Mostramos um método muito eficiente para padronização de circuitos a laser de uma tinta elástica (previamente desenvolvida na ISR) que tem potencial para fabricação em escala. Graças à implementação desses patches, esta dissertação é o primeiro trabalho que compara dispositivos de oxímetro de pulso realmente compatíveis com os não compatíveis. Os patches criados são comparados com o oxímetro de pulso digital comercial, certificado, e algumas conclusões são tiradas.There is growing interest in wearable healthcare devices due to their application in remote patient monitoring. In the case of frequent monitoring of vital signs with wearable devices, it would be possible to define an individual health baseline so that users and medical professionals could take the necessary measures, depending on the detected anomalies. Conventional medical instruments are bulky and often made from rigid electronics and are not suitable for this purpose. The mechanical mismatch between the traditional rigid electronics and biological tissues results in systems that do not adapt sufficiently to the human epidermis and are usually impractical for long-term monitoring. This has been one of the motivations for soft and stretchable electronics, which targets the development of soft-matter electronics devices that conform to the human skin and can afford bending and mechanical strain while maintaining their functionality and signal quality. This dissertation is part of a large CMU Portugal (WoW) project that aims to develop a wearable monitoring system that simultaneously monitors heart rate, body temperature, body movements, respiratory rate, and oxygen saturation. The ISR team has already implemented all of these functions in a wearable e-textile belt and an adhesive patch, except for the oxygen saturation (SpO2). Both devices have their sensors concentrated in the chest zone. However, the few works of literature that focused on measuring SpO2 in the chest zone found it challenging. However, none developed a truly skin-conformable soft-matter patch. Therefore, this work's main objective is to design and develop a soft-matter SpO2 measurement patch and understand if it is feasible to measure SpO2 in the chest zone and if a soft and conformal SpO2 monitoring patch can address this problem.In addition to this, this work addresses some of the challenges in fabricating flexible, high-resolution soft-matter electronics that can incorporate SMD microcomponents. We show a very efficient method for laser patterning of an elastic ink (previously developed at ISR) that has the potential for scalable fabrication. Thanks to implementing these patches, this dissertation is the first work that compares truly compliant pulse oximeter devices with non-compliant ones. The patches created are compared with the certified commercial finger pulse oximeter, and some conclusions are drawn.Outro - This work was partially supported by the Carnegie Mellon-Portugal project WoW (Reference No.: 45913), which had the support of the European Regional Development Fund (ERDF) and Dermotronics (PTDC/EEIROB/31784/2017), financed by the EU Structural & Investment Funds (FEEI) through an operational program of the center region, and the Foundation of Science and Technology (FCT) of Portugal.2021-11-232027-11-22T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/98587http://hdl.handle.net/10316/98587TID:202920470engCarvalheiro, José Pedro Netoinfo:eu-repo/semantics/embargoedAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-27T11:04:49Zoai:estudogeral.uc.pt:10316/98587Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:16:23.130697Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
Dispositivo Vestível para Monitoramento de SpO2 na zona torácica: Projeto, Fabricação e Validação
title Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
spellingShingle Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
Carvalheiro, José Pedro Neto
Dispositivos vestíveis
Eletrónica Conformável
Oximetria de Pulso
PPG
SpO2
Wearable devices
Conformable Electronics
Pulse Oximetry
PPG
SpO2
title_short Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
title_full Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
title_fullStr Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
title_full_unstemmed Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
title_sort Wearable SpO2 Monitoring in the Chest Zone: Design, Fabrication, and Validation
author Carvalheiro, José Pedro Neto
author_facet Carvalheiro, José Pedro Neto
author_role author
dc.contributor.author.fl_str_mv Carvalheiro, José Pedro Neto
dc.subject.por.fl_str_mv Dispositivos vestíveis
Eletrónica Conformável
Oximetria de Pulso
PPG
SpO2
Wearable devices
Conformable Electronics
Pulse Oximetry
PPG
SpO2
topic Dispositivos vestíveis
Eletrónica Conformável
Oximetria de Pulso
PPG
SpO2
Wearable devices
Conformable Electronics
Pulse Oximetry
PPG
SpO2
description Dissertação de Mestrado Integrado em Engenharia Electrotécnica e de Computadores apresentada à Faculdade de Ciências e Tecnologia
publishDate 2021
dc.date.none.fl_str_mv 2021-11-23
2027-11-22T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/98587
http://hdl.handle.net/10316/98587
TID:202920470
url http://hdl.handle.net/10316/98587
identifier_str_mv TID:202920470
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134059921670144