Formaldehyde in dwellings: environmental contamination and some emission sources
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.25758/set.384 |
Resumo: | Nowadays, indoor air contamination is considered an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related to negative health effects on occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used direct-reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted us to recognize some of the possible indoor emissions sources and to define several of the preventive measures that can be applied. |
id |
RCAP_fed81130420fd12e314f8f30af19321d |
---|---|
oai_identifier_str |
oai:journals.ipl.pt:article/697 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Formaldehyde in dwellings: environmental contamination and some emission sourcesFormaldeído em habitações domésticas: contaminação ambiental e potenciais fontesFormaldeídoHabitações domésticasQualidade do ar interiorFontes emissorasFormaldehydeDwellingsIndoor air qualityEmission sourcesNowadays, indoor air contamination is considered an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related to negative health effects on occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used direct-reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted us to recognize some of the possible indoor emissions sources and to define several of the preventive measures that can be applied.Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou-se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal.Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)2011-11-15info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.25758/set.384oai:journals.ipl.pt:article/697Saúde e Tecnologia; No. 06 (2011): Novembro 2011; 10-16Saúde & Tecnologia; N.º 06 (2011): Novembro 2011; 10-161646-9704reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://journals.ipl.pt/stecnologia/article/view/697https://doi.org/10.25758/set.384https://journals.ipl.pt/stecnologia/article/view/697/596Direitos de Autor (c) 2022 Saúde & Tecnologiainfo:eu-repo/semantics/openAccessViegas, SusanaPrista, João2022-12-20T10:59:20Zoai:journals.ipl.pt:article/697Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:21:30.067376Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Formaldehyde in dwellings: environmental contamination and some emission sources Formaldeído em habitações domésticas: contaminação ambiental e potenciais fontes |
title |
Formaldehyde in dwellings: environmental contamination and some emission sources |
spellingShingle |
Formaldehyde in dwellings: environmental contamination and some emission sources Viegas, Susana Formaldeído Habitações domésticas Qualidade do ar interior Fontes emissoras Formaldehyde Dwellings Indoor air quality Emission sources |
title_short |
Formaldehyde in dwellings: environmental contamination and some emission sources |
title_full |
Formaldehyde in dwellings: environmental contamination and some emission sources |
title_fullStr |
Formaldehyde in dwellings: environmental contamination and some emission sources |
title_full_unstemmed |
Formaldehyde in dwellings: environmental contamination and some emission sources |
title_sort |
Formaldehyde in dwellings: environmental contamination and some emission sources |
author |
Viegas, Susana |
author_facet |
Viegas, Susana Prista, João |
author_role |
author |
author2 |
Prista, João |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Viegas, Susana Prista, João |
dc.subject.por.fl_str_mv |
Formaldeído Habitações domésticas Qualidade do ar interior Fontes emissoras Formaldehyde Dwellings Indoor air quality Emission sources |
topic |
Formaldeído Habitações domésticas Qualidade do ar interior Fontes emissoras Formaldehyde Dwellings Indoor air quality Emission sources |
description |
Nowadays, indoor air contamination is considered an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related to negative health effects on occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used direct-reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted us to recognize some of the possible indoor emissions sources and to define several of the preventive measures that can be applied. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-11-15 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.25758/set.384 oai:journals.ipl.pt:article/697 |
url |
https://doi.org/10.25758/set.384 |
identifier_str_mv |
oai:journals.ipl.pt:article/697 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://journals.ipl.pt/stecnologia/article/view/697 https://doi.org/10.25758/set.384 https://journals.ipl.pt/stecnologia/article/view/697/596 |
dc.rights.driver.fl_str_mv |
Direitos de Autor (c) 2022 Saúde & Tecnologia info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos de Autor (c) 2022 Saúde & Tecnologia |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa) |
publisher.none.fl_str_mv |
Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa) |
dc.source.none.fl_str_mv |
Saúde e Tecnologia; No. 06 (2011): Novembro 2011; 10-16 Saúde & Tecnologia; N.º 06 (2011): Novembro 2011; 10-16 1646-9704 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130661946130432 |