Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids

Detalhes bibliográficos
Autor(a) principal: Sundar, L. Syam
Data de Publicação: 2020
Outros Autores: Misganaw, A.H., Singh, Manoj K., Pereira, António M.B., Sousa, António C.M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10773/37104
Resumo: Heat transfer, friction factor and efficiency of a thermosyphon type flat plate collector with and without twisted tape inserts were analyzed experimentally. Water based Cu nanofluids were used as the absorber fluid to receive the heat from solar radiation into the flat plate collector. The experiments were conducted for volume concentrations of 0.1% and 0.3% and twist ratios of H/D = 5, 10 and 15. Results reveal that the heat transfer rate and efficiency of nanofluids increase with the increase of particle volume concentrations. The Nusselt number of 0.3% nanofluid is enhanced up to 20.46%, and it is further enhanced up to 46.90% with twisted tape insert of H/D = 5 with a maximum friction factor penalty of 1.477-times compared to plain collector. The efficiency of the solar collector with water is 52% and it is enhanced to 58% for 0.3% nanofluid, whereas it is further enhanced to 64% for 0.3% nanofluid with twisted tape insert of H/D = 5. Empirical correlations are proposed based on the experimental data for the friction factor and Nusselt number with a standard deviation of less than ±6.5%. The study indicates that for 100 units of solar flat plate collector the use of 0.1% and 0.3% Cu nanofluids leads to weight savings of 284 kg and 567 kg, respectively. The total weight of 100 units of solar flat plate collector is further saved by 767 kg, 1050 kg and 1250 kg for 0.3% nanofluid with twisted tape inserts of H/D = 15, H/D = 10 and H/D = 5, respectively. The collector cost is reduced by 5.66% and 11.33% for 0.1% and 0.3% nanofluids, and it is further reduced to 25% for 0.3% nanofluid with a twisted tape insert of H/D = 5.
id RCAP_ff474ac231d36c4f4f28254b02a32a9a
oai_identifier_str oai:ria.ua.pt:10773/37104
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluidsHeat transferFriction factorThermosyphonNanofluidsTwisted tape inserts, enhancementHeat transfer, friction factor and efficiency of a thermosyphon type flat plate collector with and without twisted tape inserts were analyzed experimentally. Water based Cu nanofluids were used as the absorber fluid to receive the heat from solar radiation into the flat plate collector. The experiments were conducted for volume concentrations of 0.1% and 0.3% and twist ratios of H/D = 5, 10 and 15. Results reveal that the heat transfer rate and efficiency of nanofluids increase with the increase of particle volume concentrations. The Nusselt number of 0.3% nanofluid is enhanced up to 20.46%, and it is further enhanced up to 46.90% with twisted tape insert of H/D = 5 with a maximum friction factor penalty of 1.477-times compared to plain collector. The efficiency of the solar collector with water is 52% and it is enhanced to 58% for 0.3% nanofluid, whereas it is further enhanced to 64% for 0.3% nanofluid with twisted tape insert of H/D = 5. Empirical correlations are proposed based on the experimental data for the friction factor and Nusselt number with a standard deviation of less than ±6.5%. The study indicates that for 100 units of solar flat plate collector the use of 0.1% and 0.3% Cu nanofluids leads to weight savings of 284 kg and 567 kg, respectively. The total weight of 100 units of solar flat plate collector is further saved by 767 kg, 1050 kg and 1250 kg for 0.3% nanofluid with twisted tape inserts of H/D = 15, H/D = 10 and H/D = 5, respectively. The collector cost is reduced by 5.66% and 11.33% for 0.1% and 0.3% nanofluids, and it is further reduced to 25% for 0.3% nanofluid with a twisted tape insert of H/D = 5.Elsevier2023-04-17T11:04:33Z2020-12-01T00:00:00Z2020-12info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/37104eng1755-008410.1016/j.ref.2020.06.004Sundar, L. SyamMisganaw, A.H.Singh, Manoj K.Pereira, António M.B.Sousa, António C.M.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-22T12:11:32Zoai:ria.ua.pt:10773/37104Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T03:07:44.860948Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
title Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
spellingShingle Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
Sundar, L. Syam
Heat transfer
Friction factor
Thermosyphon
Nanofluids
Twisted tape inserts, enhancement
title_short Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
title_full Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
title_fullStr Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
title_full_unstemmed Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
title_sort Efficiency, energy and economic analysis of twisted tape inserts in a thermosyphon solar flat plate collector with Cu nanofluids
author Sundar, L. Syam
author_facet Sundar, L. Syam
Misganaw, A.H.
Singh, Manoj K.
Pereira, António M.B.
Sousa, António C.M.
author_role author
author2 Misganaw, A.H.
Singh, Manoj K.
Pereira, António M.B.
Sousa, António C.M.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Sundar, L. Syam
Misganaw, A.H.
Singh, Manoj K.
Pereira, António M.B.
Sousa, António C.M.
dc.subject.por.fl_str_mv Heat transfer
Friction factor
Thermosyphon
Nanofluids
Twisted tape inserts, enhancement
topic Heat transfer
Friction factor
Thermosyphon
Nanofluids
Twisted tape inserts, enhancement
description Heat transfer, friction factor and efficiency of a thermosyphon type flat plate collector with and without twisted tape inserts were analyzed experimentally. Water based Cu nanofluids were used as the absorber fluid to receive the heat from solar radiation into the flat plate collector. The experiments were conducted for volume concentrations of 0.1% and 0.3% and twist ratios of H/D = 5, 10 and 15. Results reveal that the heat transfer rate and efficiency of nanofluids increase with the increase of particle volume concentrations. The Nusselt number of 0.3% nanofluid is enhanced up to 20.46%, and it is further enhanced up to 46.90% with twisted tape insert of H/D = 5 with a maximum friction factor penalty of 1.477-times compared to plain collector. The efficiency of the solar collector with water is 52% and it is enhanced to 58% for 0.3% nanofluid, whereas it is further enhanced to 64% for 0.3% nanofluid with twisted tape insert of H/D = 5. Empirical correlations are proposed based on the experimental data for the friction factor and Nusselt number with a standard deviation of less than ±6.5%. The study indicates that for 100 units of solar flat plate collector the use of 0.1% and 0.3% Cu nanofluids leads to weight savings of 284 kg and 567 kg, respectively. The total weight of 100 units of solar flat plate collector is further saved by 767 kg, 1050 kg and 1250 kg for 0.3% nanofluid with twisted tape inserts of H/D = 15, H/D = 10 and H/D = 5, respectively. The collector cost is reduced by 5.66% and 11.33% for 0.1% and 0.3% nanofluids, and it is further reduced to 25% for 0.3% nanofluid with a twisted tape insert of H/D = 5.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-01T00:00:00Z
2020-12
2023-04-17T11:04:33Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/37104
url http://hdl.handle.net/10773/37104
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1755-0084
10.1016/j.ref.2020.06.004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137731713957888