Starch analysis using hydrodynamic chromatography with a mixed-bed particle column
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10198/731 |
Resumo: | Columns packed with commercial glass beads 5 and 19 μm average size and a mixture of both (0.7 volume fraction of large particles) were used to analyse starch composition by hydrodynamic chromatography (HDC), applying water as mobile phase. To obviate retrogradation, experiments were carried out at column temperatures of 15 and 3 °C and several types of starch were assayed. In what concerns amylopectin and amylose separation, a better resolution and a lower pressure drop were obtained for the mixed binary packing when compared with the packing containing uniform 5 μm glass beads. A more efficient cooling of the mobile phase was also obtained with the mixed packing, which was determinant for improving resolution. For the Hylon VII starch the relative retention times (RRT) were 0.777 and 0.964 for amylopectin and amylose, respectively, while for the Tapioca starch the obtained RRTs were 0.799 and 0.923. Application of unbound glass beads as column packing not only might reduce equipment and running costs in preparative scale separations, but also proved to be useful as a fast and reliable method to monitor the amylose and amylopectin content of starch samples of different sources. |
id |
RCAP_ffab798f144b30bed7146412be804ab8 |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/731 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle columnHDCStarch analysisTemperaturePackingGlass bedsColumns packed with commercial glass beads 5 and 19 μm average size and a mixture of both (0.7 volume fraction of large particles) were used to analyse starch composition by hydrodynamic chromatography (HDC), applying water as mobile phase. To obviate retrogradation, experiments were carried out at column temperatures of 15 and 3 °C and several types of starch were assayed. In what concerns amylopectin and amylose separation, a better resolution and a lower pressure drop were obtained for the mixed binary packing when compared with the packing containing uniform 5 μm glass beads. A more efficient cooling of the mobile phase was also obtained with the mixed packing, which was determinant for improving resolution. For the Hylon VII starch the relative retention times (RRT) were 0.777 and 0.964 for amylopectin and amylose, respectively, while for the Tapioca starch the obtained RRTs were 0.799 and 0.923. Application of unbound glass beads as column packing not only might reduce equipment and running costs in preparative scale separations, but also proved to be useful as a fast and reliable method to monitor the amylose and amylopectin content of starch samples of different sources.The authors wish to thank FCT for the grant provided to Dr. Alexander Yelshin (Yelshyn). This work was developed under the framework of the project POCI_EQU_58337/2004, partially funded by FEDER.ElsevierBiblioteca Digital do IPBDias, Ricardo P.Fernandes, Carla S.Teixeira, JoséMota, ManuelYelshin, Alexander2008-09-03T11:23:49Z20082008-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/731engDias, Ricardo P.; Fernandes, Carla S.; Teixeira, José A.; Mota, Manuel; Yelshin, Alexander (2008). Starch analysis using hydrodynamic chromatography with a mixed-bed particle column. Carbohydrate Polymers. ISSN 01448617. 74:4 p. 852-8570144-861710.1016/j.carbpol.2008.05.001info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:03:45Zoai:bibliotecadigital.ipb.pt:10198/731Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:54:23.851818Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
title |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
spellingShingle |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column Dias, Ricardo P. HDC Starch analysis Temperature Packing Glass beds |
title_short |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
title_full |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
title_fullStr |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
title_full_unstemmed |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
title_sort |
Starch analysis using hydrodynamic chromatography with a mixed-bed particle column |
author |
Dias, Ricardo P. |
author_facet |
Dias, Ricardo P. Fernandes, Carla S. Teixeira, José Mota, Manuel Yelshin, Alexander |
author_role |
author |
author2 |
Fernandes, Carla S. Teixeira, José Mota, Manuel Yelshin, Alexander |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Dias, Ricardo P. Fernandes, Carla S. Teixeira, José Mota, Manuel Yelshin, Alexander |
dc.subject.por.fl_str_mv |
HDC Starch analysis Temperature Packing Glass beds |
topic |
HDC Starch analysis Temperature Packing Glass beds |
description |
Columns packed with commercial glass beads 5 and 19 μm average size and a mixture of both (0.7 volume fraction of large particles) were used to analyse starch composition by hydrodynamic chromatography (HDC), applying water as mobile phase. To obviate retrogradation, experiments were carried out at column temperatures of 15 and 3 °C and several types of starch were assayed. In what concerns amylopectin and amylose separation, a better resolution and a lower pressure drop were obtained for the mixed binary packing when compared with the packing containing uniform 5 μm glass beads. A more efficient cooling of the mobile phase was also obtained with the mixed packing, which was determinant for improving resolution. For the Hylon VII starch the relative retention times (RRT) were 0.777 and 0.964 for amylopectin and amylose, respectively, while for the Tapioca starch the obtained RRTs were 0.799 and 0.923. Application of unbound glass beads as column packing not only might reduce equipment and running costs in preparative scale separations, but also proved to be useful as a fast and reliable method to monitor the amylose and amylopectin content of starch samples of different sources. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-09-03T11:23:49Z 2008 2008-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/731 |
url |
http://hdl.handle.net/10198/731 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Dias, Ricardo P.; Fernandes, Carla S.; Teixeira, José A.; Mota, Manuel; Yelshin, Alexander (2008). Starch analysis using hydrodynamic chromatography with a mixed-bed particle column. Carbohydrate Polymers. ISSN 01448617. 74:4 p. 852-857 0144-8617 10.1016/j.carbpol.2008.05.001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817553096522334208 |