Effect of different artificial aging protocolson fluorescence of resin composites

Detalhes bibliográficos
Autor(a) principal: Silva,Elielson Nóbrega da
Data de Publicação: 2018
Outros Autores: Correia,Ayla Macyelle de Oliveira, Bresciani,Eduardo, Caneppele,Taciana Marco Ferraz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Matéria (Rio de Janeiro. Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400416
Resumo: ABSTRACT This study evaluated the effect of different artificial aging on fluorescence of resin composites. Forty-five cylindrical specimens (6mm in diameter and 1mm thick) were made of each resin composite: IPS Empress Direct, Filtek™ Z350 XT, and Durafill. A baseline measurement of fluorescence by the direct method using the fluorescence spectrophotometer RF-5301 PC was performed. After, resin specimens were divided into 3 groups according to artificial aging protocol to be submitted: (1) aging by mechanical brushing: 30,000 cycles were performed, with fluorescence measurements after 10,000, 20,000 and 30,000 cycles; (2) chemical aging by ethanol: the samples were immersed in ethanol for 15 days, with measurements after 5, 10 and 15 days of immersion; (3) light aging: resin specimens were subjected to UV radiation for 216h with fluorescence readings after 72, 144, 216h. Data were submitted to one-way repeated measures ANOVA and Tukey’s test (α=0.05). Baseline fluorescence of the tested resins was ranked in this ascending order: Durafill < Filtek Z350 XT < IPS Empress Direct. Simulated toothbrushing and ethanol immersion reduced fluorescence, except for Z350 XT. For light exposition, fluorescence was reduced after 100h for Empress Direct and Durafill, while a reduction after 100h and 200h was detected for Z350 XT. Artificial aging protocols influenced the fluorescence and that this phenomenon is material dependent. In general, the fluorescence is reduced with aging.
id RLAM-1_2c0a8ab057ef59e4cdfb40fdf4f927cc
oai_identifier_str oai:scielo:S1517-70762018000400416
network_acronym_str RLAM-1
network_name_str Matéria (Rio de Janeiro. Online)
repository_id_str
spelling Effect of different artificial aging protocolson fluorescence of resin compositescomposite resinagingfluorescenceABSTRACT This study evaluated the effect of different artificial aging on fluorescence of resin composites. Forty-five cylindrical specimens (6mm in diameter and 1mm thick) were made of each resin composite: IPS Empress Direct, Filtek™ Z350 XT, and Durafill. A baseline measurement of fluorescence by the direct method using the fluorescence spectrophotometer RF-5301 PC was performed. After, resin specimens were divided into 3 groups according to artificial aging protocol to be submitted: (1) aging by mechanical brushing: 30,000 cycles were performed, with fluorescence measurements after 10,000, 20,000 and 30,000 cycles; (2) chemical aging by ethanol: the samples were immersed in ethanol for 15 days, with measurements after 5, 10 and 15 days of immersion; (3) light aging: resin specimens were subjected to UV radiation for 216h with fluorescence readings after 72, 144, 216h. Data were submitted to one-way repeated measures ANOVA and Tukey’s test (α=0.05). Baseline fluorescence of the tested resins was ranked in this ascending order: Durafill < Filtek Z350 XT < IPS Empress Direct. Simulated toothbrushing and ethanol immersion reduced fluorescence, except for Z350 XT. For light exposition, fluorescence was reduced after 100h for Empress Direct and Durafill, while a reduction after 100h and 200h was detected for Z350 XT. Artificial aging protocols influenced the fluorescence and that this phenomenon is material dependent. In general, the fluorescence is reduced with aging.Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiroem cooperação com a Associação Brasileira do Hidrogênio, ABH22018-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400416Matéria (Rio de Janeiro) v.23 n.4 2018reponame:Matéria (Rio de Janeiro. Online)instname:Matéria (Rio de Janeiro. Online)instacron:RLAM10.1590/s1517-707620180004.0559info:eu-repo/semantics/openAccessSilva,Elielson Nóbrega daCorreia,Ayla Macyelle de OliveiraBresciani,EduardoCaneppele,Taciana Marco Ferrazeng2018-12-03T00:00:00Zoai:scielo:S1517-70762018000400416Revistahttp://www.materia.coppe.ufrj.br/https://old.scielo.br/oai/scielo-oai.php||materia@labh2.coppe.ufrj.br1517-70761517-7076opendoar:2018-12-03T00:00Matéria (Rio de Janeiro. Online) - Matéria (Rio de Janeiro. Online)false
dc.title.none.fl_str_mv Effect of different artificial aging protocolson fluorescence of resin composites
title Effect of different artificial aging protocolson fluorescence of resin composites
spellingShingle Effect of different artificial aging protocolson fluorescence of resin composites
Silva,Elielson Nóbrega da
composite resin
aging
fluorescence
title_short Effect of different artificial aging protocolson fluorescence of resin composites
title_full Effect of different artificial aging protocolson fluorescence of resin composites
title_fullStr Effect of different artificial aging protocolson fluorescence of resin composites
title_full_unstemmed Effect of different artificial aging protocolson fluorescence of resin composites
title_sort Effect of different artificial aging protocolson fluorescence of resin composites
author Silva,Elielson Nóbrega da
author_facet Silva,Elielson Nóbrega da
Correia,Ayla Macyelle de Oliveira
Bresciani,Eduardo
Caneppele,Taciana Marco Ferraz
author_role author
author2 Correia,Ayla Macyelle de Oliveira
Bresciani,Eduardo
Caneppele,Taciana Marco Ferraz
author2_role author
author
author
dc.contributor.author.fl_str_mv Silva,Elielson Nóbrega da
Correia,Ayla Macyelle de Oliveira
Bresciani,Eduardo
Caneppele,Taciana Marco Ferraz
dc.subject.por.fl_str_mv composite resin
aging
fluorescence
topic composite resin
aging
fluorescence
description ABSTRACT This study evaluated the effect of different artificial aging on fluorescence of resin composites. Forty-five cylindrical specimens (6mm in diameter and 1mm thick) were made of each resin composite: IPS Empress Direct, Filtek™ Z350 XT, and Durafill. A baseline measurement of fluorescence by the direct method using the fluorescence spectrophotometer RF-5301 PC was performed. After, resin specimens were divided into 3 groups according to artificial aging protocol to be submitted: (1) aging by mechanical brushing: 30,000 cycles were performed, with fluorescence measurements after 10,000, 20,000 and 30,000 cycles; (2) chemical aging by ethanol: the samples were immersed in ethanol for 15 days, with measurements after 5, 10 and 15 days of immersion; (3) light aging: resin specimens were subjected to UV radiation for 216h with fluorescence readings after 72, 144, 216h. Data were submitted to one-way repeated measures ANOVA and Tukey’s test (α=0.05). Baseline fluorescence of the tested resins was ranked in this ascending order: Durafill < Filtek Z350 XT < IPS Empress Direct. Simulated toothbrushing and ethanol immersion reduced fluorescence, except for Z350 XT. For light exposition, fluorescence was reduced after 100h for Empress Direct and Durafill, while a reduction after 100h and 200h was detected for Z350 XT. Artificial aging protocols influenced the fluorescence and that this phenomenon is material dependent. In general, the fluorescence is reduced with aging.
publishDate 2018
dc.date.none.fl_str_mv 2018-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400416
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400416
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1517-707620180004.0559
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro
em cooperação com a Associação Brasileira do Hidrogênio, ABH2
publisher.none.fl_str_mv Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro
em cooperação com a Associação Brasileira do Hidrogênio, ABH2
dc.source.none.fl_str_mv Matéria (Rio de Janeiro) v.23 n.4 2018
reponame:Matéria (Rio de Janeiro. Online)
instname:Matéria (Rio de Janeiro. Online)
instacron:RLAM
instname_str Matéria (Rio de Janeiro. Online)
instacron_str RLAM
institution RLAM
reponame_str Matéria (Rio de Janeiro. Online)
collection Matéria (Rio de Janeiro. Online)
repository.name.fl_str_mv Matéria (Rio de Janeiro. Online) - Matéria (Rio de Janeiro. Online)
repository.mail.fl_str_mv ||materia@labh2.coppe.ufrj.br
_version_ 1752126691498524672