Tooth whitening affects bond strength of adhesive systems in enamel

Detalhes bibliográficos
Autor(a) principal: Lima Neto,Cantídio Francisco de
Data de Publicação: 2018
Outros Autores: Silva,Carolina Batista da, Silva,Marcos Aurélio Bomfim da, Vitti,Rafael Pino, Zanta,Carmem Lúcia de Paiva e Silva, Tonholo,Josealdo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Matéria (Rio de Janeiro. Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400418
Resumo: ABSTRACT This study presents how the tooth whitening affects the bond strength and fracture type of three distinct adhesives — a conventional, a self-etching, and a universal adhesive — in enamel. Health bovine incisors were prepared by flattening the labial surface; part of these teeth was submitted to whitening treatment with a peroxide-based product (WhiteGold Office© 35%). The Single Bond©, AdheSE©, or Single Bond Universal© adhesive system were used to adhere a block of restorative resin to the flat surface of the teeth. Sticks measuring 10x1x1 mm were prepared and used in microtensile tests; they were also employed to examine the type of fracture. The results are analyzed with a two-way ANOVA. For both whitened and non-whitened specimens, the adhesive systems did not give statistically different bond strength values. However, the fracture shape (classified into four types) varied from a cohesive enamel type fracture for the whitened samples to a predominantly cohesive resin type fracture for the non-whitened teeth. Therefore, the whitening procedure has exerted a weakening effect on enamel even after 21 days post-treatment.
id RLAM-1_8a305af9aead7bb1a265a46e50684734
oai_identifier_str oai:scielo:S1517-70762018000400418
network_acronym_str RLAM-1
network_name_str Matéria (Rio de Janeiro. Online)
repository_id_str
spelling Tooth whitening affects bond strength of adhesive systems in enamelTooth whiteningadhesive systemsbond strengthfracturerestorative systemABSTRACT This study presents how the tooth whitening affects the bond strength and fracture type of three distinct adhesives — a conventional, a self-etching, and a universal adhesive — in enamel. Health bovine incisors were prepared by flattening the labial surface; part of these teeth was submitted to whitening treatment with a peroxide-based product (WhiteGold Office© 35%). The Single Bond©, AdheSE©, or Single Bond Universal© adhesive system were used to adhere a block of restorative resin to the flat surface of the teeth. Sticks measuring 10x1x1 mm were prepared and used in microtensile tests; they were also employed to examine the type of fracture. The results are analyzed with a two-way ANOVA. For both whitened and non-whitened specimens, the adhesive systems did not give statistically different bond strength values. However, the fracture shape (classified into four types) varied from a cohesive enamel type fracture for the whitened samples to a predominantly cohesive resin type fracture for the non-whitened teeth. Therefore, the whitening procedure has exerted a weakening effect on enamel even after 21 days post-treatment.Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiroem cooperação com a Associação Brasileira do Hidrogênio, ABH22018-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400418Matéria (Rio de Janeiro) v.23 n.4 2018reponame:Matéria (Rio de Janeiro. Online)instname:Matéria (Rio de Janeiro. Online)instacron:RLAM10.1590/s1517-707620180004.0561info:eu-repo/semantics/openAccessLima Neto,Cantídio Francisco deSilva,Carolina Batista daSilva,Marcos Aurélio Bomfim daVitti,Rafael PinoZanta,Carmem Lúcia de Paiva e SilvaTonholo,Josealdoeng2018-12-04T00:00:00Zoai:scielo:S1517-70762018000400418Revistahttp://www.materia.coppe.ufrj.br/https://old.scielo.br/oai/scielo-oai.php||materia@labh2.coppe.ufrj.br1517-70761517-7076opendoar:2018-12-04T00:00Matéria (Rio de Janeiro. Online) - Matéria (Rio de Janeiro. Online)false
dc.title.none.fl_str_mv Tooth whitening affects bond strength of adhesive systems in enamel
title Tooth whitening affects bond strength of adhesive systems in enamel
spellingShingle Tooth whitening affects bond strength of adhesive systems in enamel
Lima Neto,Cantídio Francisco de
Tooth whitening
adhesive systems
bond strength
fracture
restorative system
title_short Tooth whitening affects bond strength of adhesive systems in enamel
title_full Tooth whitening affects bond strength of adhesive systems in enamel
title_fullStr Tooth whitening affects bond strength of adhesive systems in enamel
title_full_unstemmed Tooth whitening affects bond strength of adhesive systems in enamel
title_sort Tooth whitening affects bond strength of adhesive systems in enamel
author Lima Neto,Cantídio Francisco de
author_facet Lima Neto,Cantídio Francisco de
Silva,Carolina Batista da
Silva,Marcos Aurélio Bomfim da
Vitti,Rafael Pino
Zanta,Carmem Lúcia de Paiva e Silva
Tonholo,Josealdo
author_role author
author2 Silva,Carolina Batista da
Silva,Marcos Aurélio Bomfim da
Vitti,Rafael Pino
Zanta,Carmem Lúcia de Paiva e Silva
Tonholo,Josealdo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Lima Neto,Cantídio Francisco de
Silva,Carolina Batista da
Silva,Marcos Aurélio Bomfim da
Vitti,Rafael Pino
Zanta,Carmem Lúcia de Paiva e Silva
Tonholo,Josealdo
dc.subject.por.fl_str_mv Tooth whitening
adhesive systems
bond strength
fracture
restorative system
topic Tooth whitening
adhesive systems
bond strength
fracture
restorative system
description ABSTRACT This study presents how the tooth whitening affects the bond strength and fracture type of three distinct adhesives — a conventional, a self-etching, and a universal adhesive — in enamel. Health bovine incisors were prepared by flattening the labial surface; part of these teeth was submitted to whitening treatment with a peroxide-based product (WhiteGold Office© 35%). The Single Bond©, AdheSE©, or Single Bond Universal© adhesive system were used to adhere a block of restorative resin to the flat surface of the teeth. Sticks measuring 10x1x1 mm were prepared and used in microtensile tests; they were also employed to examine the type of fracture. The results are analyzed with a two-way ANOVA. For both whitened and non-whitened specimens, the adhesive systems did not give statistically different bond strength values. However, the fracture shape (classified into four types) varied from a cohesive enamel type fracture for the whitened samples to a predominantly cohesive resin type fracture for the non-whitened teeth. Therefore, the whitening procedure has exerted a weakening effect on enamel even after 21 days post-treatment.
publishDate 2018
dc.date.none.fl_str_mv 2018-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400418
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-70762018000400418
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1517-707620180004.0561
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro
em cooperação com a Associação Brasileira do Hidrogênio, ABH2
publisher.none.fl_str_mv Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro
em cooperação com a Associação Brasileira do Hidrogênio, ABH2
dc.source.none.fl_str_mv Matéria (Rio de Janeiro) v.23 n.4 2018
reponame:Matéria (Rio de Janeiro. Online)
instname:Matéria (Rio de Janeiro. Online)
instacron:RLAM
instname_str Matéria (Rio de Janeiro. Online)
instacron_str RLAM
institution RLAM
reponame_str Matéria (Rio de Janeiro. Online)
collection Matéria (Rio de Janeiro. Online)
repository.name.fl_str_mv Matéria (Rio de Janeiro. Online) - Matéria (Rio de Janeiro. Online)
repository.mail.fl_str_mv ||materia@labh2.coppe.ufrj.br
_version_ 1752126691502718976