Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Anestesiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600395 |
Resumo: | Background and objectives: The intense trauma response triggered by cardiopulmonary bypass can lead to increased morbidity and mortality. The present study evaluated whether clonidine, a drug of the class of α-2 agonists, administered by spinal route, without association with local anesthetics or opioids, reduces this response in cardiac surgery with cardiopulmonary bypass. Method: A total of 27 patients between 18 and 75 years old, divided by non-blinded fashion into a control group (15) and a clonidine group (12), were studied. All patients underwent identical technique of general anesthesia. Then, only the clonidine group received 1 μg kg−1 clonidine by spinal route. Levels of blood glucose, lactate and cortisol were measured at three consecutive times: T1, at the time of installation of invasive arterial pressure; T2, 10 min after the first dose for cardioplegia; and T3, at the time of skin suture; and troponin I values at T1 and T3. The variation of results between T2-T1, T3-T2, and T3-T1 was also evaluated. Results: There was a statistically significant difference only with respect to the variation in blood glucose in the clonidine group: T3-T2, p = 0.027 and T3-T1, p = 0.047. Conclusions: Spinal clonidine at a dose of 1 μg kg−1 did not decrease blood measurements of troponin, cortisol, or lactate. Blood glucose suffered a more moderate variation during the procedure in the clonidine group. This fact, already reported in the literature, requires further investigation to be clarified. |
id |
SBA-1_2358a902b9ac288dd0a03f5c5e95a4ce |
---|---|
oai_identifier_str |
oai:scielo:S0034-70942014000600395 |
network_acronym_str |
SBA-1 |
network_name_str |
Revista Brasileira de Anestesiologia (Online) |
repository_id_str |
|
spelling |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypassClonidineTraumatic stressCardiac surgery Background and objectives: The intense trauma response triggered by cardiopulmonary bypass can lead to increased morbidity and mortality. The present study evaluated whether clonidine, a drug of the class of α-2 agonists, administered by spinal route, without association with local anesthetics or opioids, reduces this response in cardiac surgery with cardiopulmonary bypass. Method: A total of 27 patients between 18 and 75 years old, divided by non-blinded fashion into a control group (15) and a clonidine group (12), were studied. All patients underwent identical technique of general anesthesia. Then, only the clonidine group received 1 μg kg−1 clonidine by spinal route. Levels of blood glucose, lactate and cortisol were measured at three consecutive times: T1, at the time of installation of invasive arterial pressure; T2, 10 min after the first dose for cardioplegia; and T3, at the time of skin suture; and troponin I values at T1 and T3. The variation of results between T2-T1, T3-T2, and T3-T1 was also evaluated. Results: There was a statistically significant difference only with respect to the variation in blood glucose in the clonidine group: T3-T2, p = 0.027 and T3-T1, p = 0.047. Conclusions: Spinal clonidine at a dose of 1 μg kg−1 did not decrease blood measurements of troponin, cortisol, or lactate. Blood glucose suffered a more moderate variation during the procedure in the clonidine group. This fact, already reported in the literature, requires further investigation to be clarified. Sociedade Brasileira de Anestesiologia2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600395Revista Brasileira de Anestesiologia v.64 n.6 2014reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2013.04.012info:eu-repo/semantics/openAccessFerreira,Claudia Gissi da RochaTenório,Sérgio Bernardoeng2015-08-25T00:00:00Zoai:scielo:S0034-70942014000600395Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2015-08-25T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
dc.title.none.fl_str_mv |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
title |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
spellingShingle |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass Ferreira,Claudia Gissi da Rocha Clonidine Traumatic stress Cardiac surgery |
title_short |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
title_full |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
title_fullStr |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
title_full_unstemmed |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
title_sort |
Subarachnoid clonidine and trauma response in cardiac surgery with cardiopulmonary bypass |
author |
Ferreira,Claudia Gissi da Rocha |
author_facet |
Ferreira,Claudia Gissi da Rocha Tenório,Sérgio Bernardo |
author_role |
author |
author2 |
Tenório,Sérgio Bernardo |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Ferreira,Claudia Gissi da Rocha Tenório,Sérgio Bernardo |
dc.subject.por.fl_str_mv |
Clonidine Traumatic stress Cardiac surgery |
topic |
Clonidine Traumatic stress Cardiac surgery |
description |
Background and objectives: The intense trauma response triggered by cardiopulmonary bypass can lead to increased morbidity and mortality. The present study evaluated whether clonidine, a drug of the class of α-2 agonists, administered by spinal route, without association with local anesthetics or opioids, reduces this response in cardiac surgery with cardiopulmonary bypass. Method: A total of 27 patients between 18 and 75 years old, divided by non-blinded fashion into a control group (15) and a clonidine group (12), were studied. All patients underwent identical technique of general anesthesia. Then, only the clonidine group received 1 μg kg−1 clonidine by spinal route. Levels of blood glucose, lactate and cortisol were measured at three consecutive times: T1, at the time of installation of invasive arterial pressure; T2, 10 min after the first dose for cardioplegia; and T3, at the time of skin suture; and troponin I values at T1 and T3. The variation of results between T2-T1, T3-T2, and T3-T1 was also evaluated. Results: There was a statistically significant difference only with respect to the variation in blood glucose in the clonidine group: T3-T2, p = 0.027 and T3-T1, p = 0.047. Conclusions: Spinal clonidine at a dose of 1 μg kg−1 did not decrease blood measurements of troponin, cortisol, or lactate. Blood glucose suffered a more moderate variation during the procedure in the clonidine group. This fact, already reported in the literature, requires further investigation to be clarified. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600395 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600395 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjane.2013.04.012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.64 n.6 2014 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
instacron_str |
SBA |
institution |
SBA |
reponame_str |
Revista Brasileira de Anestesiologia (Online) |
collection |
Revista Brasileira de Anestesiologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
_version_ |
1752126628197040128 |