Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial

Detalhes bibliográficos
Autor(a) principal: Ma,Jing
Data de Publicação: 2020
Outros Autores: Peng,Mian, Wang,Fei, Chen,Lei, Zhang,Zong-Ze, Wang,Yan-Lin
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Anestesiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000600605
Resumo: Abstract Background and objectives Preoperative use of flurbiprofen axetil (FA) is extensively adopted to modulate the effects of analgesia. However, the relationship between FA and sedation agents remains unclear. In this study, we aimed to investigate the effects of different doses of FA on the median Effective Concentration (EC50) of propofol. Methods Ninety-six patients (ASA I or II, aged 18–65 years) were randomly assigned into one of four groups in a 1:1:1:1 ratio. Group A (control group) received 10 mL of Intralipid, and groups B, C and D received 0.5 mg.kg−1, 0.75 mg.kg−1 and 1 mg.kg−1 of FA, respectively, 10 minutes before induction. The depth of anesthesia was measured by the Bispectral Index (BIS). The “up-and-down” method was used to calculate the EC50 of propofol. During the equilibration period, if BIS ≤ 50 (or BIS > 50), the next patient would receive a 0.5 µg.mL−1-lower (or -higher) propofol Target-Controlled Infusion (TCI) concentration. The hemodynamic data were recorded at baseline, 10 minutes after FA administration, after induction, after intubation and 15 minutes after intubation. Results The EC50 of propofol was lower in Group C (2.32 µg.mL−1, 95% Confidence Interval [95% CI] 1.85–2.75) and D (2.39 µg.mL−1, 95% CI 1.91–2.67) than in Group A (2.96 µg.mL−1, 95% CI 2.55–3.33) (p = 0.023, p = 0.048, respectively). There were no significant differences in the EC50 between Group B (2.53 µg.mL−1, 95% CI 2.33–2.71) and Group A (p > 0.05). There were no significant differences in Heart Rate (HR) among groups A, B and C. The HR was significantly lower in Group D than in Group A after intubation (66 ± 6 vs. 80 ± 10 bpm, p < 0.01) and 15 minutes after intubation (61 ± 4 vs. 70 ± 8 bpm, p < 0.01). There were no significant differences among the four groups in Mean Arterial Pressure (MAP) at any time point. The MAP of the four groups was significantly lower after induction, after intubation, and 15 minutes after intubation than at baseline (p < 0.05). Conclusion High-dose FA (0.75 mg.kg−1 or 1 mg.kg−1) reduces the EC50 of propofol, and 1 mg.kg−1 FA reduces the HR for adequate anesthesia in unstimulated patients. Although this result should be investigated in cases of surgical stimulation, we suggest that FA pre-administration may reduce the propofol requirement when the depth of anesthesia is measured by BIS.
id SBA-1_49913e35989fa428b7eb99a44ef65ee3
oai_identifier_str oai:scielo:S0034-70942020000600605
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trialFlurbiprofen axetilNSAIDsMedian effective concentrationPropofolAbstract Background and objectives Preoperative use of flurbiprofen axetil (FA) is extensively adopted to modulate the effects of analgesia. However, the relationship between FA and sedation agents remains unclear. In this study, we aimed to investigate the effects of different doses of FA on the median Effective Concentration (EC50) of propofol. Methods Ninety-six patients (ASA I or II, aged 18–65 years) were randomly assigned into one of four groups in a 1:1:1:1 ratio. Group A (control group) received 10 mL of Intralipid, and groups B, C and D received 0.5 mg.kg−1, 0.75 mg.kg−1 and 1 mg.kg−1 of FA, respectively, 10 minutes before induction. The depth of anesthesia was measured by the Bispectral Index (BIS). The “up-and-down” method was used to calculate the EC50 of propofol. During the equilibration period, if BIS ≤ 50 (or BIS > 50), the next patient would receive a 0.5 µg.mL−1-lower (or -higher) propofol Target-Controlled Infusion (TCI) concentration. The hemodynamic data were recorded at baseline, 10 minutes after FA administration, after induction, after intubation and 15 minutes after intubation. Results The EC50 of propofol was lower in Group C (2.32 µg.mL−1, 95% Confidence Interval [95% CI] 1.85–2.75) and D (2.39 µg.mL−1, 95% CI 1.91–2.67) than in Group A (2.96 µg.mL−1, 95% CI 2.55–3.33) (p = 0.023, p = 0.048, respectively). There were no significant differences in the EC50 between Group B (2.53 µg.mL−1, 95% CI 2.33–2.71) and Group A (p > 0.05). There were no significant differences in Heart Rate (HR) among groups A, B and C. The HR was significantly lower in Group D than in Group A after intubation (66 ± 6 vs. 80 ± 10 bpm, p < 0.01) and 15 minutes after intubation (61 ± 4 vs. 70 ± 8 bpm, p < 0.01). There were no significant differences among the four groups in Mean Arterial Pressure (MAP) at any time point. The MAP of the four groups was significantly lower after induction, after intubation, and 15 minutes after intubation than at baseline (p < 0.05). Conclusion High-dose FA (0.75 mg.kg−1 or 1 mg.kg−1) reduces the EC50 of propofol, and 1 mg.kg−1 FA reduces the HR for adequate anesthesia in unstimulated patients. Although this result should be investigated in cases of surgical stimulation, we suggest that FA pre-administration may reduce the propofol requirement when the depth of anesthesia is measured by BIS.Sociedade Brasileira de Anestesiologia2020-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000600605Revista Brasileira de Anestesiologia v.70 n.6 2020reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2020.10.002info:eu-repo/semantics/openAccessMa,JingPeng,MianWang,FeiChen,LeiZhang,Zong-ZeWang,Yan-Lineng2021-01-29T00:00:00Zoai:scielo:S0034-70942020000600605Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2021-01-29T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
title Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
spellingShingle Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
Ma,Jing
Flurbiprofen axetil
NSAIDs
Median effective concentration
Propofol
title_short Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
title_full Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
title_fullStr Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
title_full_unstemmed Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
title_sort Effect of pre-administered flurbiprofen axetil on the EC50 of propofol during anesthesia in unstimulated patients: a randomized clinical trial
author Ma,Jing
author_facet Ma,Jing
Peng,Mian
Wang,Fei
Chen,Lei
Zhang,Zong-Ze
Wang,Yan-Lin
author_role author
author2 Peng,Mian
Wang,Fei
Chen,Lei
Zhang,Zong-Ze
Wang,Yan-Lin
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ma,Jing
Peng,Mian
Wang,Fei
Chen,Lei
Zhang,Zong-Ze
Wang,Yan-Lin
dc.subject.por.fl_str_mv Flurbiprofen axetil
NSAIDs
Median effective concentration
Propofol
topic Flurbiprofen axetil
NSAIDs
Median effective concentration
Propofol
description Abstract Background and objectives Preoperative use of flurbiprofen axetil (FA) is extensively adopted to modulate the effects of analgesia. However, the relationship between FA and sedation agents remains unclear. In this study, we aimed to investigate the effects of different doses of FA on the median Effective Concentration (EC50) of propofol. Methods Ninety-six patients (ASA I or II, aged 18–65 years) were randomly assigned into one of four groups in a 1:1:1:1 ratio. Group A (control group) received 10 mL of Intralipid, and groups B, C and D received 0.5 mg.kg−1, 0.75 mg.kg−1 and 1 mg.kg−1 of FA, respectively, 10 minutes before induction. The depth of anesthesia was measured by the Bispectral Index (BIS). The “up-and-down” method was used to calculate the EC50 of propofol. During the equilibration period, if BIS ≤ 50 (or BIS > 50), the next patient would receive a 0.5 µg.mL−1-lower (or -higher) propofol Target-Controlled Infusion (TCI) concentration. The hemodynamic data were recorded at baseline, 10 minutes after FA administration, after induction, after intubation and 15 minutes after intubation. Results The EC50 of propofol was lower in Group C (2.32 µg.mL−1, 95% Confidence Interval [95% CI] 1.85–2.75) and D (2.39 µg.mL−1, 95% CI 1.91–2.67) than in Group A (2.96 µg.mL−1, 95% CI 2.55–3.33) (p = 0.023, p = 0.048, respectively). There were no significant differences in the EC50 between Group B (2.53 µg.mL−1, 95% CI 2.33–2.71) and Group A (p > 0.05). There were no significant differences in Heart Rate (HR) among groups A, B and C. The HR was significantly lower in Group D than in Group A after intubation (66 ± 6 vs. 80 ± 10 bpm, p < 0.01) and 15 minutes after intubation (61 ± 4 vs. 70 ± 8 bpm, p < 0.01). There were no significant differences among the four groups in Mean Arterial Pressure (MAP) at any time point. The MAP of the four groups was significantly lower after induction, after intubation, and 15 minutes after intubation than at baseline (p < 0.05). Conclusion High-dose FA (0.75 mg.kg−1 or 1 mg.kg−1) reduces the EC50 of propofol, and 1 mg.kg−1 FA reduces the HR for adequate anesthesia in unstimulated patients. Although this result should be investigated in cases of surgical stimulation, we suggest that FA pre-administration may reduce the propofol requirement when the depth of anesthesia is measured by BIS.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000600605
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942020000600605
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2020.10.002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.70 n.6 2020
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126630873006080