When one port does not return blood: two case reports of rare causes for misplaced central venous catheters

Detalhes bibliográficos
Autor(a) principal: Pereira,Sandra
Data de Publicação: 2016
Outros Autores: Preto,César, Pinho,Carla, Vasconcelos,Pedro
Tipo de documento: Relatório
Idioma: eng
Título da fonte: Revista Brasileira de Anestesiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000100078
Resumo: We present two cases of misplaced central venous catheters having in common theabsence of free blood return from one lumen immediately after placement. The former is acase of right hydrothorax associated with central venous catheterization with the catheter tipin intra-pleural location. In this case the distal port was never patent. In the latter case therewas an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not beundervalued. In these circumstances the catheter should not be used and needs to be removed.
id SBA-1_60cd0bed81075658d4c082865cf2b146
oai_identifier_str oai:scielo:S0034-70942016000100078
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling When one port does not return blood: two case reports of rare causes for misplaced central venous cathetersCentral venous catheterHydrothoraxLoopingMalpositionWe present two cases of misplaced central venous catheters having in common theabsence of free blood return from one lumen immediately after placement. The former is acase of right hydrothorax associated with central venous catheterization with the catheter tipin intra-pleural location. In this case the distal port was never patent. In the latter case therewas an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not beundervalued. In these circumstances the catheter should not be used and needs to be removed.Sociedade Brasileira de Anestesiologia2016-02-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000100078Revista Brasileira de Anestesiologia v.66 n.1 2016reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2014.02.007info:eu-repo/semantics/openAccessPereira,SandraPreto,CésarPinho,CarlaVasconcelos,Pedroeng2016-02-15T00:00:00Zoai:scielo:S0034-70942016000100078Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2016-02-15T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
title When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
spellingShingle When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
Pereira,Sandra
Central venous catheter
Hydrothorax
Looping
Malposition
title_short When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
title_full When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
title_fullStr When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
title_full_unstemmed When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
title_sort When one port does not return blood: two case reports of rare causes for misplaced central venous catheters
author Pereira,Sandra
author_facet Pereira,Sandra
Preto,César
Pinho,Carla
Vasconcelos,Pedro
author_role author
author2 Preto,César
Pinho,Carla
Vasconcelos,Pedro
author2_role author
author
author
dc.contributor.author.fl_str_mv Pereira,Sandra
Preto,César
Pinho,Carla
Vasconcelos,Pedro
dc.subject.por.fl_str_mv Central venous catheter
Hydrothorax
Looping
Malposition
topic Central venous catheter
Hydrothorax
Looping
Malposition
description We present two cases of misplaced central venous catheters having in common theabsence of free blood return from one lumen immediately after placement. The former is acase of right hydrothorax associated with central venous catheterization with the catheter tipin intra-pleural location. In this case the distal port was never patent. In the latter case therewas an increased aspiration pressure through the middle port due to a catheter looping.The absence of free flow on aspiration from one lumen of a central catheter should not beundervalued. In these circumstances the catheter should not be used and needs to be removed.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000100078
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000100078
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2014.02.007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.66 n.1 2016
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126628629053440