Bilateral mandibular nerve injury following mask ventilation: a case report
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Anestesiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942018000400425 |
Resumo: | Abstract Background and objectives Nerve injury following mask ventilation is a rare but serious anesthetic complication. The majority of reported cases are associated with excessive pressure applied to the face mask, long duration of mask ventilation, excessive digital pressure behind the mandible to relieve airway obstruction and pressure exerted by the plastic oropharyngeal airway. Case report We present a case of bilateral mandibular nerve injury following mask ventilation with short duration, most likely due to a semi-silicone facemask with an over-inflated cushion. Conclusion An over-inflated sealing cushion of a facemask may trigger difficult mask ventilation leading to mandibular nerve injury following mask ventilation. Alternative airway management techniques such as laryngeal mask airway should be considered when airway maintenance can only be achieved with strong pressure applied to the facemask and/or mandible. |
id |
SBA-1_9daa95a827354544a70f6f023a4751ed |
---|---|
oai_identifier_str |
oai:scielo:S0034-70942018000400425 |
network_acronym_str |
SBA-1 |
network_name_str |
Revista Brasileira de Anestesiologia (Online) |
repository_id_str |
|
spelling |
Bilateral mandibular nerve injury following mask ventilation: a case reportMandibular nerve injuryMask ventilationAnesthesiaAbstract Background and objectives Nerve injury following mask ventilation is a rare but serious anesthetic complication. The majority of reported cases are associated with excessive pressure applied to the face mask, long duration of mask ventilation, excessive digital pressure behind the mandible to relieve airway obstruction and pressure exerted by the plastic oropharyngeal airway. Case report We present a case of bilateral mandibular nerve injury following mask ventilation with short duration, most likely due to a semi-silicone facemask with an over-inflated cushion. Conclusion An over-inflated sealing cushion of a facemask may trigger difficult mask ventilation leading to mandibular nerve injury following mask ventilation. Alternative airway management techniques such as laryngeal mask airway should be considered when airway maintenance can only be achieved with strong pressure applied to the facemask and/or mandible.Sociedade Brasileira de Anestesiologia2018-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942018000400425Revista Brasileira de Anestesiologia v.68 n.4 2018reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2018.01.005info:eu-repo/semantics/openAccessTuncali,BahattinZeyneloglu,Pinareng2018-07-23T00:00:00Zoai:scielo:S0034-70942018000400425Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2018-07-23T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
dc.title.none.fl_str_mv |
Bilateral mandibular nerve injury following mask ventilation: a case report |
title |
Bilateral mandibular nerve injury following mask ventilation: a case report |
spellingShingle |
Bilateral mandibular nerve injury following mask ventilation: a case report Tuncali,Bahattin Mandibular nerve injury Mask ventilation Anesthesia |
title_short |
Bilateral mandibular nerve injury following mask ventilation: a case report |
title_full |
Bilateral mandibular nerve injury following mask ventilation: a case report |
title_fullStr |
Bilateral mandibular nerve injury following mask ventilation: a case report |
title_full_unstemmed |
Bilateral mandibular nerve injury following mask ventilation: a case report |
title_sort |
Bilateral mandibular nerve injury following mask ventilation: a case report |
author |
Tuncali,Bahattin |
author_facet |
Tuncali,Bahattin Zeyneloglu,Pinar |
author_role |
author |
author2 |
Zeyneloglu,Pinar |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Tuncali,Bahattin Zeyneloglu,Pinar |
dc.subject.por.fl_str_mv |
Mandibular nerve injury Mask ventilation Anesthesia |
topic |
Mandibular nerve injury Mask ventilation Anesthesia |
description |
Abstract Background and objectives Nerve injury following mask ventilation is a rare but serious anesthetic complication. The majority of reported cases are associated with excessive pressure applied to the face mask, long duration of mask ventilation, excessive digital pressure behind the mandible to relieve airway obstruction and pressure exerted by the plastic oropharyngeal airway. Case report We present a case of bilateral mandibular nerve injury following mask ventilation with short duration, most likely due to a semi-silicone facemask with an over-inflated cushion. Conclusion An over-inflated sealing cushion of a facemask may trigger difficult mask ventilation leading to mandibular nerve injury following mask ventilation. Alternative airway management techniques such as laryngeal mask airway should be considered when airway maintenance can only be achieved with strong pressure applied to the facemask and/or mandible. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942018000400425 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942018000400425 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjane.2018.01.005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.68 n.4 2018 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
instacron_str |
SBA |
institution |
SBA |
reponame_str |
Revista Brasileira de Anestesiologia (Online) |
collection |
Revista Brasileira de Anestesiologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
_version_ |
1752126630041485312 |