Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance

Detalhes bibliográficos
Autor(a) principal: Polat,Reyhan
Data de Publicação: 2015
Outros Autores: Aydin,Gözde Bumin, Ergil,Jülide, Sayin,Murat, Kokulu,Tuğba, Öztürk,Ibrahim
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Anestesiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500343
Resumo: ABSTRACTPURPOSE: The i-gelTM is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway ClassicTM with respect to the clinical performance.METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation.RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p = 0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6 ± 2.4 s versus 13.1 ± 1.8 s [p = 0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p = 0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24 h after the procedure (p = 0.752).CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
id SBA-1_cfdd21fba541d66ff10ee7a8198a99b6
oai_identifier_str oai:scielo:S0034-70942015000500343
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performanceLaryngeal Mask Airway Classici-gelSupraglottic airway devicesABSTRACTPURPOSE: The i-gelTM is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway ClassicTM with respect to the clinical performance.METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation.RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p = 0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6 ± 2.4 s versus 13.1 ± 1.8 s [p = 0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p = 0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24 h after the procedure (p = 0.752).CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.Sociedade Brasileira de Anestesiologia2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500343Revista Brasileira de Anestesiologia v.65 n.5 2015reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2014.02.009info:eu-repo/semantics/openAccessPolat,ReyhanAydin,Gözde BuminErgil,JülideSayin,MuratKokulu,TuğbaÖztürk,Ibrahimeng2015-10-20T00:00:00Zoai:scielo:S0034-70942015000500343Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2015-10-20T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
title Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
spellingShingle Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
Polat,Reyhan
Laryngeal Mask Airway Classic
i-gel
Supraglottic airway devices
title_short Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
title_full Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
title_fullStr Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
title_full_unstemmed Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
title_sort Comparison of the i-gelTM and the Laryngeal Mask Airway ClassicTM in terms of clinical performance
author Polat,Reyhan
author_facet Polat,Reyhan
Aydin,Gözde Bumin
Ergil,Jülide
Sayin,Murat
Kokulu,Tuğba
Öztürk,Ibrahim
author_role author
author2 Aydin,Gözde Bumin
Ergil,Jülide
Sayin,Murat
Kokulu,Tuğba
Öztürk,Ibrahim
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Polat,Reyhan
Aydin,Gözde Bumin
Ergil,Jülide
Sayin,Murat
Kokulu,Tuğba
Öztürk,Ibrahim
dc.subject.por.fl_str_mv Laryngeal Mask Airway Classic
i-gel
Supraglottic airway devices
topic Laryngeal Mask Airway Classic
i-gel
Supraglottic airway devices
description ABSTRACTPURPOSE: The i-gelTM is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway ClassicTM with respect to the clinical performance.METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation.RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p = 0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6 ± 2.4 s versus 13.1 ± 1.8 s [p = 0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p = 0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24 h after the procedure (p = 0.752).CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
publishDate 2015
dc.date.none.fl_str_mv 2015-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500343
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500343
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2014.02.009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.65 n.5 2015
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126628547264512