Bedside prediction of right subclavian venous catheter insertion length
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Anestesiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600419 |
Resumo: | Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV) catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC), via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively). Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89). The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm) = -0.037 + 0.036 × Height (cm) + 0.903 × I-T-IC (cm) (adjusted r2 =0.64). Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation. |
id |
SBA-1_df779dc28d9228e1fec9aafe9672228f |
---|---|
oai_identifier_str |
oai:scielo:S0034-70942014000600419 |
network_acronym_str |
SBA-1 |
network_name_str |
Revista Brasileira de Anestesiologia (Online) |
repository_id_str |
|
spelling |
Bedside prediction of right subclavian venous catheter insertion lengthCentral venous catheterClavicular notchSubclavian vein Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV) catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC), via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively). Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89). The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm) = -0.037 + 0.036 × Height (cm) + 0.903 × I-T-IC (cm) (adjusted r2 =0.64). Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation. Sociedade Brasileira de Anestesiologia2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600419Revista Brasileira de Anestesiologia v.64 n.6 2014reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2013.10.004info:eu-repo/semantics/openAccessChoi,Yoon JiHahm,Kyung-DonKwon,KooLee,Eun-HoRo,Young JinYang,Hong Seukeng2015-08-25T00:00:00Zoai:scielo:S0034-70942014000600419Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2015-08-25T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
dc.title.none.fl_str_mv |
Bedside prediction of right subclavian venous catheter insertion length |
title |
Bedside prediction of right subclavian venous catheter insertion length |
spellingShingle |
Bedside prediction of right subclavian venous catheter insertion length Choi,Yoon Ji Central venous catheter Clavicular notch Subclavian vein |
title_short |
Bedside prediction of right subclavian venous catheter insertion length |
title_full |
Bedside prediction of right subclavian venous catheter insertion length |
title_fullStr |
Bedside prediction of right subclavian venous catheter insertion length |
title_full_unstemmed |
Bedside prediction of right subclavian venous catheter insertion length |
title_sort |
Bedside prediction of right subclavian venous catheter insertion length |
author |
Choi,Yoon Ji |
author_facet |
Choi,Yoon Ji Hahm,Kyung-Don Kwon,Koo Lee,Eun-Ho Ro,Young Jin Yang,Hong Seuk |
author_role |
author |
author2 |
Hahm,Kyung-Don Kwon,Koo Lee,Eun-Ho Ro,Young Jin Yang,Hong Seuk |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Choi,Yoon Ji Hahm,Kyung-Don Kwon,Koo Lee,Eun-Ho Ro,Young Jin Yang,Hong Seuk |
dc.subject.por.fl_str_mv |
Central venous catheter Clavicular notch Subclavian vein |
topic |
Central venous catheter Clavicular notch Subclavian vein |
description |
Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV) catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC), via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively). Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89). The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm) = -0.037 + 0.036 × Height (cm) + 0.903 × I-T-IC (cm) (adjusted r2 =0.64). Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600419 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600419 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjane.2013.10.004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.64 n.6 2014 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
instacron_str |
SBA |
institution |
SBA |
reponame_str |
Revista Brasileira de Anestesiologia (Online) |
collection |
Revista Brasileira de Anestesiologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
_version_ |
1752126628205428736 |