Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492016000300197
Resumo: Abstract Background Carotid endarterectomy (CEA) and carotid artery stenting (CAS) have both been proposed for treatment of critical atherosclerotic stenosis located at the carotid bifurcation. Monitoring of hyperintense microembolic signals (MES) by transcranial Doppler ultrasound (TCD) is considered a method of quality control, both in CEA and in CAS. Objective To analyze temporal distribution of MES throughout both semi-eversion CEA and CAS procedures and to evaluate changes in mean velocity of blood flow through the ipsilateral middle cerebral artery (MCA). Method Thirty-three procedures (17 CEA and 16 CAS) were prospectively monitored using TCD and the data were related to three different stages of surgery (pre-cerebral protection, during cerebral protection and post-cerebral protection). Chi-square, Mann-Whitney, ANOVA and contrast tests were used for statistical analysis. Results The MES were uniformly distributed in the CEA group, but not in the CAS group (p = 0.208). The number of MES was higher in the CAS group in all stages. The average flow in the MCA was similarly lower in both groups during the protection stage. Conclusion CEA provoked a lower incidence of MES per procedure than CAS in all stages. The behavior of the averages of the mean of blood flow through the MCA was similar in both groups.
id SBACV-1_30433d087fe5c1693966b4196eb48a28
oai_identifier_str oai:scielo:S1677-54492016000300197
network_acronym_str SBACV-1
network_name_str Jornal Vascular Brasileiro (Online)
repository_id_str
spelling A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomycarotid stenosiscarotid endarterectomytranscranial Doppler ultrasonographyAbstract Background Carotid endarterectomy (CEA) and carotid artery stenting (CAS) have both been proposed for treatment of critical atherosclerotic stenosis located at the carotid bifurcation. Monitoring of hyperintense microembolic signals (MES) by transcranial Doppler ultrasound (TCD) is considered a method of quality control, both in CEA and in CAS. Objective To analyze temporal distribution of MES throughout both semi-eversion CEA and CAS procedures and to evaluate changes in mean velocity of blood flow through the ipsilateral middle cerebral artery (MCA). Method Thirty-three procedures (17 CEA and 16 CAS) were prospectively monitored using TCD and the data were related to three different stages of surgery (pre-cerebral protection, during cerebral protection and post-cerebral protection). Chi-square, Mann-Whitney, ANOVA and contrast tests were used for statistical analysis. Results The MES were uniformly distributed in the CEA group, but not in the CAS group (p = 0.208). The number of MES was higher in the CAS group in all stages. The average flow in the MCA was similarly lower in both groups during the protection stage. Conclusion CEA provoked a lower incidence of MES per procedure than CAS in all stages. The behavior of the averages of the mean of blood flow through the MCA was similar in both groups.Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)2016-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492016000300197Jornal Vascular Brasileiro v.15 n.3 2016reponame:Jornal Vascular Brasileiro (Online)instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)instacron:SBACV10.1590/1677-5449.003316info:eu-repo/semantics/openAccessOlveira,Germano da PazGuillaumon,Ana TerezinhaBenvindo,Sérgio ClementinoLima,Joana Mayra TeixeiraBarreto,Sérgio Ricardo FreireAvelar,Wagner MauadCendes,Fernandoeng2016-10-26T00:00:00Zoai:scielo:S1677-54492016000300197Revistahttp://www.scielo.br/jvbhttps://old.scielo.br/oai/scielo-oai.php||secretaria@sbacv.org.br1677-73011677-5449opendoar:2016-10-26T00:00Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)false
dc.title.none.fl_str_mv A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
title A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
spellingShingle A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
Olveira,Germano da Paz
carotid stenosis
carotid endarterectomy
transcranial Doppler ultrasonography
title_short A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
title_full A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
title_fullStr A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
title_full_unstemmed A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
title_sort A comparative analysis of transcranial Doppler parameters acquired during carotid stenting and semi-eversion carotid endarterectomy
author Olveira,Germano da Paz
author_facet Olveira,Germano da Paz
Guillaumon,Ana Terezinha
Benvindo,Sérgio Clementino
Lima,Joana Mayra Teixeira
Barreto,Sérgio Ricardo Freire
Avelar,Wagner Mauad
Cendes,Fernando
author_role author
author2 Guillaumon,Ana Terezinha
Benvindo,Sérgio Clementino
Lima,Joana Mayra Teixeira
Barreto,Sérgio Ricardo Freire
Avelar,Wagner Mauad
Cendes,Fernando
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Olveira,Germano da Paz
Guillaumon,Ana Terezinha
Benvindo,Sérgio Clementino
Lima,Joana Mayra Teixeira
Barreto,Sérgio Ricardo Freire
Avelar,Wagner Mauad
Cendes,Fernando
dc.subject.por.fl_str_mv carotid stenosis
carotid endarterectomy
transcranial Doppler ultrasonography
topic carotid stenosis
carotid endarterectomy
transcranial Doppler ultrasonography
description Abstract Background Carotid endarterectomy (CEA) and carotid artery stenting (CAS) have both been proposed for treatment of critical atherosclerotic stenosis located at the carotid bifurcation. Monitoring of hyperintense microembolic signals (MES) by transcranial Doppler ultrasound (TCD) is considered a method of quality control, both in CEA and in CAS. Objective To analyze temporal distribution of MES throughout both semi-eversion CEA and CAS procedures and to evaluate changes in mean velocity of blood flow through the ipsilateral middle cerebral artery (MCA). Method Thirty-three procedures (17 CEA and 16 CAS) were prospectively monitored using TCD and the data were related to three different stages of surgery (pre-cerebral protection, during cerebral protection and post-cerebral protection). Chi-square, Mann-Whitney, ANOVA and contrast tests were used for statistical analysis. Results The MES were uniformly distributed in the CEA group, but not in the CAS group (p = 0.208). The number of MES was higher in the CAS group in all stages. The average flow in the MCA was similarly lower in both groups during the protection stage. Conclusion CEA provoked a lower incidence of MES per procedure than CAS in all stages. The behavior of the averages of the mean of blood flow through the MCA was similar in both groups.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492016000300197
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492016000300197
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1677-5449.003316
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
publisher.none.fl_str_mv Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
dc.source.none.fl_str_mv Jornal Vascular Brasileiro v.15 n.3 2016
reponame:Jornal Vascular Brasileiro (Online)
instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
instacron:SBACV
instname_str Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
instacron_str SBACV
institution SBACV
reponame_str Jornal Vascular Brasileiro (Online)
collection Jornal Vascular Brasileiro (Online)
repository.name.fl_str_mv Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
repository.mail.fl_str_mv ||secretaria@sbacv.org.br
_version_ 1752126647617716224