Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Vascular Brasileiro (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492014000100027 |
Resumo: | INTRODUCTION: The conventional method for measuring the ankle-brachial index (ABI) requires a vascular Doppler machine and a trained professional, which is a barrier to the examination becoming more widely adopted across health services. For this reason, the possibility of substituting Doppler monitors for other types of device has been investigated. The objective of this study was to assess the validity, reliability and accuracy of taking ABI measurement using oscillometric devices and compare them to vascular Doppler.METHODS: This is an integrative literature review of four articles.RESULTS: There was very little uniformity between the four studies in terms of ample populations or the methodological procedures used to measure systolic pressures. The results for sensitivity, specificity and positive and negative predictive values varied and so did measures of reliability.CONCLUSIONS: The results of these studies do not provide a basis from which conclusions can be drawn on the validity, reliability or accuracy of employing oscillometric devices as a substitute for Doppler for determination of ABI. |
id |
SBACV-1_d07a82ac938500bf0b1e04a0a30da66b |
---|---|
oai_identifier_str |
oai:scielo:S1677-54492014000100027 |
network_acronym_str |
SBACV-1 |
network_name_str |
Jornal Vascular Brasileiro (Online) |
repository_id_str |
|
spelling |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative reviewankle-brachial indexperipheral arterial diseasearterial blood pressure measurementINTRODUCTION: The conventional method for measuring the ankle-brachial index (ABI) requires a vascular Doppler machine and a trained professional, which is a barrier to the examination becoming more widely adopted across health services. For this reason, the possibility of substituting Doppler monitors for other types of device has been investigated. The objective of this study was to assess the validity, reliability and accuracy of taking ABI measurement using oscillometric devices and compare them to vascular Doppler.METHODS: This is an integrative literature review of four articles.RESULTS: There was very little uniformity between the four studies in terms of ample populations or the methodological procedures used to measure systolic pressures. The results for sensitivity, specificity and positive and negative predictive values varied and so did measures of reliability.CONCLUSIONS: The results of these studies do not provide a basis from which conclusions can be drawn on the validity, reliability or accuracy of employing oscillometric devices as a substitute for Doppler for determination of ABI.Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)2014-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492014000100027Jornal Vascular Brasileiro v.13 n.1 2014reponame:Jornal Vascular Brasileiro (Online)instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)instacron:SBACV10.1590/jvb.2014.006info:eu-repo/semantics/openAccessGengo e Silva,Rita de CassiaMelo,Vanessa Ferreira Amorim deLima,Maria Aparecida de Medeiroseng2015-09-14T00:00:00Zoai:scielo:S1677-54492014000100027Revistahttp://www.scielo.br/jvbhttps://old.scielo.br/oai/scielo-oai.php||secretaria@sbacv.org.br1677-73011677-5449opendoar:2015-09-14T00:00Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)false |
dc.title.none.fl_str_mv |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
title |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
spellingShingle |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review Gengo e Silva,Rita de Cassia ankle-brachial index peripheral arterial disease arterial blood pressure measurement |
title_short |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
title_full |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
title_fullStr |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
title_full_unstemmed |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
title_sort |
Validity, reliability and accuracy of oscillometric devices, compared with Doppler ultrasound, for determination of the Ankle Brachial Index: an integrative review |
author |
Gengo e Silva,Rita de Cassia |
author_facet |
Gengo e Silva,Rita de Cassia Melo,Vanessa Ferreira Amorim de Lima,Maria Aparecida de Medeiros |
author_role |
author |
author2 |
Melo,Vanessa Ferreira Amorim de Lima,Maria Aparecida de Medeiros |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Gengo e Silva,Rita de Cassia Melo,Vanessa Ferreira Amorim de Lima,Maria Aparecida de Medeiros |
dc.subject.por.fl_str_mv |
ankle-brachial index peripheral arterial disease arterial blood pressure measurement |
topic |
ankle-brachial index peripheral arterial disease arterial blood pressure measurement |
description |
INTRODUCTION: The conventional method for measuring the ankle-brachial index (ABI) requires a vascular Doppler machine and a trained professional, which is a barrier to the examination becoming more widely adopted across health services. For this reason, the possibility of substituting Doppler monitors for other types of device has been investigated. The objective of this study was to assess the validity, reliability and accuracy of taking ABI measurement using oscillometric devices and compare them to vascular Doppler.METHODS: This is an integrative literature review of four articles.RESULTS: There was very little uniformity between the four studies in terms of ample populations or the methodological procedures used to measure systolic pressures. The results for sensitivity, specificity and positive and negative predictive values varied and so did measures of reliability.CONCLUSIONS: The results of these studies do not provide a basis from which conclusions can be drawn on the validity, reliability or accuracy of employing oscillometric devices as a substitute for Doppler for determination of ABI. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492014000100027 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492014000100027 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/jvb.2014.006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) |
publisher.none.fl_str_mv |
Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) |
dc.source.none.fl_str_mv |
Jornal Vascular Brasileiro v.13 n.1 2014 reponame:Jornal Vascular Brasileiro (Online) instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) instacron:SBACV |
instname_str |
Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) |
instacron_str |
SBACV |
institution |
SBACV |
reponame_str |
Jornal Vascular Brasileiro (Online) |
collection |
Jornal Vascular Brasileiro (Online) |
repository.name.fl_str_mv |
Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV) |
repository.mail.fl_str_mv |
||secretaria@sbacv.org.br |
_version_ |
1752126646833381376 |