Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect

Detalhes bibliográficos
Autor(a) principal: Nascimento,Erivelton Alessandro do
Data de Publicação: 2018
Outros Autores: Reis,Christiane Cigagna Wiefels, Ribeiro,Fernanda Baptista, Alves,Christiane Rodrigues, Silva,Eduardo Nani, Ribeiro,Mario Luiz, Mesquita,Claudio Tinoco
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018001600607
Resumo: Abstract Background: Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response. Objectives: To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT. Methods: This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%. Results: We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002). Conclusion: CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.
id SBC-1_04984609c6a09bc52f88c7e481b8af56
oai_identifier_str oai:scielo:S0066-782X2018001600607
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion SpectHeart FailureCardiac Resynchronization TherapyEletrodes,ImplantedStroke VolumeRadionuclide ImagingAbstract Background: Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response. Objectives: To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT. Methods: This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%. Results: We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002). Conclusion: CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.Sociedade Brasileira de Cardiologia - SBC2018-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018001600607Arquivos Brasileiros de Cardiologia v.111 n.4 2018reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/abc.20180159info:eu-repo/semantics/openAccessNascimento,Erivelton Alessandro doReis,Christiane Cigagna WiefelsRibeiro,Fernanda BaptistaAlves,Christiane RodriguesSilva,Eduardo NaniRibeiro,Mario LuizMesquita,Claudio Tinocoeng2018-10-18T00:00:00Zoai:scielo:S0066-782X2018001600607Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2018-10-18T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
title Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
spellingShingle Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
Nascimento,Erivelton Alessandro do
Heart Failure
Cardiac Resynchronization Therapy
Eletrodes,Implanted
Stroke Volume
Radionuclide Imaging
title_short Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
title_full Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
title_fullStr Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
title_full_unstemmed Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
title_sort Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect
author Nascimento,Erivelton Alessandro do
author_facet Nascimento,Erivelton Alessandro do
Reis,Christiane Cigagna Wiefels
Ribeiro,Fernanda Baptista
Alves,Christiane Rodrigues
Silva,Eduardo Nani
Ribeiro,Mario Luiz
Mesquita,Claudio Tinoco
author_role author
author2 Reis,Christiane Cigagna Wiefels
Ribeiro,Fernanda Baptista
Alves,Christiane Rodrigues
Silva,Eduardo Nani
Ribeiro,Mario Luiz
Mesquita,Claudio Tinoco
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Nascimento,Erivelton Alessandro do
Reis,Christiane Cigagna Wiefels
Ribeiro,Fernanda Baptista
Alves,Christiane Rodrigues
Silva,Eduardo Nani
Ribeiro,Mario Luiz
Mesquita,Claudio Tinoco
dc.subject.por.fl_str_mv Heart Failure
Cardiac Resynchronization Therapy
Eletrodes,Implanted
Stroke Volume
Radionuclide Imaging
topic Heart Failure
Cardiac Resynchronization Therapy
Eletrodes,Implanted
Stroke Volume
Radionuclide Imaging
description Abstract Background: Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response. Objectives: To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT. Methods: This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%. Results: We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002). Conclusion: CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.
publishDate 2018
dc.date.none.fl_str_mv 2018-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018001600607
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018001600607
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/abc.20180159
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.111 n.4 2018
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126568742780928