Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos Brasileiros de Cardiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018000200151 |
Resumo: | Abstract Background: The uninterrupted use of oral anticoagulation (OAC) with vitamin K antagonists (VKAs) for electrophysiology procedures has been more and more recommended. The clinical practice in our service recommends the continuous use of these drugs for atrial flutter ablation. There is little evidence as to the uninterrupted use of non-vitamin K antagonist oral anticoagulants (NOACs) in this scenario. Objective: To compare the rates of complications related with the uninterrupted use of different types of oral anticoagulants in patients referred to atrial flutter (AFL) ablation. Methods: Historical, single-center cohort of ablation procedures by AFL conducted from November 2012 to April 2016. The primary outcome was the occurrence of hemorrhagic or embolic complication during the procedure. The secondary outcome was the occurrence of stroke or transient ischemic attack (TIA) in follow-up. The statistical significance level was 5%. Results: There were 288 ablations per AFL; 154 were carried out with the uninterrupted use of OAC (57.8% with VKA and 42.2% with NOAC). Mean age was 57 ± 13 years. The rate of hemorrhagic complication during the procedure was 3% in each group (p = NS). The rate of stroke/TIA was, respectively, of 56/1,000 people-year in the VKA group against zero/1,000 people-year in the NOAC group (p = 0.02). Conclusion: In our population there were no hemorrhagic complications regarding the procedure of OAC use uninterruptedly, including NOACs. There was higher occurrence of stroke/TIA in the follow-up of the group of patients undergoing VKAs; however, this difference may not only be a result of the type of OAC used. |
id |
SBC-1_3de1dc0b26c90957dcbdae6af5b1e43b |
---|---|
oai_identifier_str |
oai:scielo:S0066-782X2018000200151 |
network_acronym_str |
SBC-1 |
network_name_str |
Arquivos Brasileiros de Cardiologia (Online) |
repository_id_str |
|
spelling |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 PatientsAnticoagulantsVitamin KCatheter AblationAtrial FlutterThromboembolismAbstract Background: The uninterrupted use of oral anticoagulation (OAC) with vitamin K antagonists (VKAs) for electrophysiology procedures has been more and more recommended. The clinical practice in our service recommends the continuous use of these drugs for atrial flutter ablation. There is little evidence as to the uninterrupted use of non-vitamin K antagonist oral anticoagulants (NOACs) in this scenario. Objective: To compare the rates of complications related with the uninterrupted use of different types of oral anticoagulants in patients referred to atrial flutter (AFL) ablation. Methods: Historical, single-center cohort of ablation procedures by AFL conducted from November 2012 to April 2016. The primary outcome was the occurrence of hemorrhagic or embolic complication during the procedure. The secondary outcome was the occurrence of stroke or transient ischemic attack (TIA) in follow-up. The statistical significance level was 5%. Results: There were 288 ablations per AFL; 154 were carried out with the uninterrupted use of OAC (57.8% with VKA and 42.2% with NOAC). Mean age was 57 ± 13 years. The rate of hemorrhagic complication during the procedure was 3% in each group (p = NS). The rate of stroke/TIA was, respectively, of 56/1,000 people-year in the VKA group against zero/1,000 people-year in the NOAC group (p = 0.02). Conclusion: In our population there were no hemorrhagic complications regarding the procedure of OAC use uninterruptedly, including NOACs. There was higher occurrence of stroke/TIA in the follow-up of the group of patients undergoing VKAs; however, this difference may not only be a result of the type of OAC used.Sociedade Brasileira de Cardiologia - SBC2018-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018000200151Arquivos Brasileiros de Cardiologia v.110 n.2 2018reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/abc.20180001info:eu-repo/semantics/openAccessLeiria,Tiago Luiz LuzMedeiros,Alexandre KrelingAlmeida,Eduardo DytzLey,Antonio Lessa GaudieSantos,Catarine Benta Lopes dosSant'Anna,Roberto ToffaniKruse,Marcelo LapaPires,Leonardo MartinsLima,Gustavo Glotz deeng2018-03-16T00:00:00Zoai:scielo:S0066-782X2018000200151Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2018-03-16T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false |
dc.title.none.fl_str_mv |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
title |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
spellingShingle |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients Leiria,Tiago Luiz Luz Anticoagulants Vitamin K Catheter Ablation Atrial Flutter Thromboembolism |
title_short |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
title_full |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
title_fullStr |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
title_full_unstemmed |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
title_sort |
Uninterrupted Use of Oral Anticoagulants for the Ablation of Atrial Flutter: A Single Center Cohort of 154 Patients |
author |
Leiria,Tiago Luiz Luz |
author_facet |
Leiria,Tiago Luiz Luz Medeiros,Alexandre Kreling Almeida,Eduardo Dytz Ley,Antonio Lessa Gaudie Santos,Catarine Benta Lopes dos Sant'Anna,Roberto Toffani Kruse,Marcelo Lapa Pires,Leonardo Martins Lima,Gustavo Glotz de |
author_role |
author |
author2 |
Medeiros,Alexandre Kreling Almeida,Eduardo Dytz Ley,Antonio Lessa Gaudie Santos,Catarine Benta Lopes dos Sant'Anna,Roberto Toffani Kruse,Marcelo Lapa Pires,Leonardo Martins Lima,Gustavo Glotz de |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Leiria,Tiago Luiz Luz Medeiros,Alexandre Kreling Almeida,Eduardo Dytz Ley,Antonio Lessa Gaudie Santos,Catarine Benta Lopes dos Sant'Anna,Roberto Toffani Kruse,Marcelo Lapa Pires,Leonardo Martins Lima,Gustavo Glotz de |
dc.subject.por.fl_str_mv |
Anticoagulants Vitamin K Catheter Ablation Atrial Flutter Thromboembolism |
topic |
Anticoagulants Vitamin K Catheter Ablation Atrial Flutter Thromboembolism |
description |
Abstract Background: The uninterrupted use of oral anticoagulation (OAC) with vitamin K antagonists (VKAs) for electrophysiology procedures has been more and more recommended. The clinical practice in our service recommends the continuous use of these drugs for atrial flutter ablation. There is little evidence as to the uninterrupted use of non-vitamin K antagonist oral anticoagulants (NOACs) in this scenario. Objective: To compare the rates of complications related with the uninterrupted use of different types of oral anticoagulants in patients referred to atrial flutter (AFL) ablation. Methods: Historical, single-center cohort of ablation procedures by AFL conducted from November 2012 to April 2016. The primary outcome was the occurrence of hemorrhagic or embolic complication during the procedure. The secondary outcome was the occurrence of stroke or transient ischemic attack (TIA) in follow-up. The statistical significance level was 5%. Results: There were 288 ablations per AFL; 154 were carried out with the uninterrupted use of OAC (57.8% with VKA and 42.2% with NOAC). Mean age was 57 ± 13 years. The rate of hemorrhagic complication during the procedure was 3% in each group (p = NS). The rate of stroke/TIA was, respectively, of 56/1,000 people-year in the VKA group against zero/1,000 people-year in the NOAC group (p = 0.02). Conclusion: In our population there were no hemorrhagic complications regarding the procedure of OAC use uninterruptedly, including NOACs. There was higher occurrence of stroke/TIA in the follow-up of the group of patients undergoing VKAs; however, this difference may not only be a result of the type of OAC used. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018000200151 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2018000200151 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/abc.20180001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Cardiologia - SBC |
publisher.none.fl_str_mv |
Sociedade Brasileira de Cardiologia - SBC |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Cardiologia v.110 n.2 2018 reponame:Arquivos Brasileiros de Cardiologia (Online) instname:Sociedade Brasileira de Cardiologia (SBC) instacron:SBC |
instname_str |
Sociedade Brasileira de Cardiologia (SBC) |
instacron_str |
SBC |
institution |
SBC |
reponame_str |
Arquivos Brasileiros de Cardiologia (Online) |
collection |
Arquivos Brasileiros de Cardiologia (Online) |
repository.name.fl_str_mv |
Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC) |
repository.mail.fl_str_mv |
||arquivos@cardiol.br |
_version_ |
1752126568664137728 |