Resumo: OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.
id SBC-1_4ee38e8f67ccab4cf03d6ea85b36bd76
oai_identifier_str oai:scielo:S0066-782X2002000300004
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Diseasemyocardial perfusionechocardiographic contrast/microbubblescoronary diseaseOBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.Sociedade Brasileira de Cardiologia - SBC2002-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2002000300004Arquivos Brasileiros de Cardiologia v.78 n.3 2002reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.1590/S0066-782X2002000300004info:eu-repo/semantics/openAccessMorcerf,FernandoMoraes,AlvaroCarrinho,MarciaDohmann,Hans J. F.eng2002-04-19T00:00:00Zoai:scielo:S0066-782X2002000300004Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2002-04-19T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
title Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
spellingShingle Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
Morcerf,Fernando
myocardial perfusion
echocardiographic contrast/microbubbles
coronary disease
title_short Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
title_full Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
title_fullStr Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
title_full_unstemmed Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
title_sort Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography) and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease
author Morcerf,Fernando
author_facet Morcerf,Fernando
Moraes,Alvaro
Carrinho,Marcia
Dohmann,Hans J. F.
author_role author
author2 Moraes,Alvaro
Carrinho,Marcia
Dohmann,Hans J. F.
author2_role author
author
author
dc.contributor.author.fl_str_mv Morcerf,Fernando
Moraes,Alvaro
Carrinho,Marcia
Dohmann,Hans J. F.
dc.subject.por.fl_str_mv myocardial perfusion
echocardiographic contrast/microbubbles
coronary disease
topic myocardial perfusion
echocardiographic contrast/microbubbles
coronary disease
description OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (1:1) second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75%) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99%) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97%) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.
publishDate 2002
dc.date.none.fl_str_mv 2002-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2002000300004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2002000300004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0066-782X2002000300004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.78 n.3 2002
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126552072519680