Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients

Detalhes bibliográficos
Autor(a) principal: Chalela,Willliam A.
Data de Publicação: 1999
Outros Autores: Moffa,Paulo J., Ramires,José A. F., Moraes,Aguinaldo P., Soares Jr,José, Meneghetti,José C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X1999000500001
Resumo: OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.
id SBC-1_50f4051693faf07a2318cfd54d5832d9
oai_identifier_str oai:scielo:S0066-782X1999000500001
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patientsmyocardial viabilitycoronary artery diseasemyocardial perfusion scintigraphyOBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.Sociedade Brasileira de Cardiologia - SBC1999-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X1999000500001Arquivos Brasileiros de Cardiologia v.72 n.5 1999reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.1590/S0066-782X1999000500001info:eu-repo/semantics/openAccessChalela,Willliam A.Moffa,Paulo J.Ramires,José A. F.Moraes,Aguinaldo P.Soares Jr,JoséMeneghetti,José C.eng2000-10-27T00:00:00Zoai:scielo:S0066-782X1999000500001Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2000-10-27T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
title Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
spellingShingle Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
Chalela,Willliam A.
myocardial viability
coronary artery disease
myocardial perfusion scintigraphy
title_short Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
title_full Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
title_fullStr Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
title_full_unstemmed Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
title_sort Detection of the viable myocardium. A perfusion scintigraphic study, before and after coronary bypass surgery in myocardial infarction patients
author Chalela,Willliam A.
author_facet Chalela,Willliam A.
Moffa,Paulo J.
Ramires,José A. F.
Moraes,Aguinaldo P.
Soares Jr,José
Meneghetti,José C.
author_role author
author2 Moffa,Paulo J.
Ramires,José A. F.
Moraes,Aguinaldo P.
Soares Jr,José
Meneghetti,José C.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Chalela,Willliam A.
Moffa,Paulo J.
Ramires,José A. F.
Moraes,Aguinaldo P.
Soares Jr,José
Meneghetti,José C.
dc.subject.por.fl_str_mv myocardial viability
coronary artery disease
myocardial perfusion scintigraphy
topic myocardial viability
coronary artery disease
myocardial perfusion scintigraphy
description OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.
publishDate 1999
dc.date.none.fl_str_mv 1999-05-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X1999000500001
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X1999000500001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0066-782X1999000500001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.72 n.5 1999
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126550882385920