Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos Brasileiros de Cardiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017000200143 |
Resumo: | Abstract Background: Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. Objective: To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. Methods: A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. Results: There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. Conclusion: The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. |
id |
SBC-1_57b44eaf0826b978028d8b12f27b328e |
---|---|
oai_identifier_str |
oai:scielo:S0066-782X2017000200143 |
network_acronym_str |
SBC-1 |
network_name_str |
Arquivos Brasileiros de Cardiologia (Online) |
repository_id_str |
|
spelling |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care LevelHypertensionRisk FactorsBlood Pressure Monitoring, AmbulatoryPrimary Health CareAntihypertensive AgentsAbstract Background: Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. Objective: To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. Methods: A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. Results: There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. Conclusion: The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines.Sociedade Brasileira de Cardiologia - SBC2017-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017000200143Arquivos Brasileiros de Cardiologia v.108 n.2 2017reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/abc.20160204info:eu-repo/semantics/openAccessGrezzana,Guilherme BrasilMoraes,David WilliamStein,Airton TetelbonPellanda,Lucia Camposeng2017-03-20T00:00:00Zoai:scielo:S0066-782X2017000200143Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2017-03-20T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false |
dc.title.none.fl_str_mv |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
title |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
spellingShingle |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level Grezzana,Guilherme Brasil Hypertension Risk Factors Blood Pressure Monitoring, Ambulatory Primary Health Care Antihypertensive Agents |
title_short |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
title_full |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
title_fullStr |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
title_full_unstemmed |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
title_sort |
Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level |
author |
Grezzana,Guilherme Brasil |
author_facet |
Grezzana,Guilherme Brasil Moraes,David William Stein,Airton Tetelbon Pellanda,Lucia Campos |
author_role |
author |
author2 |
Moraes,David William Stein,Airton Tetelbon Pellanda,Lucia Campos |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Grezzana,Guilherme Brasil Moraes,David William Stein,Airton Tetelbon Pellanda,Lucia Campos |
dc.subject.por.fl_str_mv |
Hypertension Risk Factors Blood Pressure Monitoring, Ambulatory Primary Health Care Antihypertensive Agents |
topic |
Hypertension Risk Factors Blood Pressure Monitoring, Ambulatory Primary Health Care Antihypertensive Agents |
description |
Abstract Background: Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. Objective: To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. Methods: A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. Results: There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. Conclusion: The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017000200143 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017000200143 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/abc.20160204 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Cardiologia - SBC |
publisher.none.fl_str_mv |
Sociedade Brasileira de Cardiologia - SBC |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Cardiologia v.108 n.2 2017 reponame:Arquivos Brasileiros de Cardiologia (Online) instname:Sociedade Brasileira de Cardiologia (SBC) instacron:SBC |
instname_str |
Sociedade Brasileira de Cardiologia (SBC) |
instacron_str |
SBC |
institution |
SBC |
reponame_str |
Arquivos Brasileiros de Cardiologia (Online) |
collection |
Arquivos Brasileiros de Cardiologia (Online) |
repository.name.fl_str_mv |
Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC) |
repository.mail.fl_str_mv |
||arquivos@cardiol.br |
_version_ |
1752126567707836416 |