Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results

Detalhes bibliográficos
Autor(a) principal: Ramos,Auristela I. O.
Data de Publicação: 2003
Outros Autores: Ramos,Rui F., Togna,Dorival J. D., Arnoni,Antoninho S., Staico,Rodolfo, Galo,Mercedes M., Meneghelo,Zilda M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003001200006
Resumo: OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.
id SBC-1_7483b6b1360fc70aa2238e3324aed2bd
oai_identifier_str oai:scielo:S0066-782X2003001200006
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term resultsfibrinolytic therapythrombosisstreptokinasecardiac valvular prosthesesOBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.Sociedade Brasileira de Cardiologia - SBC2003-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003001200006Arquivos Brasileiros de Cardiologia v.81 n.4 2003reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.1590/S0066-782X2003001200006info:eu-repo/semantics/openAccessRamos,Auristela I. O.Ramos,Rui F.Togna,Dorival J. D.Arnoni,Antoninho S.Staico,RodolfoGalo,Mercedes M.Meneghelo,Zilda M.eng2003-11-05T00:00:00Zoai:scielo:S0066-782X2003001200006Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2003-11-05T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
title Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
spellingShingle Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
Ramos,Auristela I. O.
fibrinolytic therapy
thrombosis
streptokinase
cardiac valvular prostheses
title_short Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
title_full Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
title_fullStr Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
title_full_unstemmed Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
title_sort Fibrinolytic therapy for thrombosis in cardiac valvular prosthesis short and long term results
author Ramos,Auristela I. O.
author_facet Ramos,Auristela I. O.
Ramos,Rui F.
Togna,Dorival J. D.
Arnoni,Antoninho S.
Staico,Rodolfo
Galo,Mercedes M.
Meneghelo,Zilda M.
author_role author
author2 Ramos,Rui F.
Togna,Dorival J. D.
Arnoni,Antoninho S.
Staico,Rodolfo
Galo,Mercedes M.
Meneghelo,Zilda M.
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ramos,Auristela I. O.
Ramos,Rui F.
Togna,Dorival J. D.
Arnoni,Antoninho S.
Staico,Rodolfo
Galo,Mercedes M.
Meneghelo,Zilda M.
dc.subject.por.fl_str_mv fibrinolytic therapy
thrombosis
streptokinase
cardiac valvular prostheses
topic fibrinolytic therapy
thrombosis
streptokinase
cardiac valvular prostheses
description OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.
publishDate 2003
dc.date.none.fl_str_mv 2003-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003001200006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003001200006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0066-782X2003001200006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.81 n.4 2003
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126552866291712